My-D047 Digital Radiography System X-ray

China My-D047 Digital Radiography System X-ray, Find details about China X-Ray, Digital Radiography System from My-D047 Digital Radiography System X-ray

Model NO.
MY-D047
Detector
17 X 17 in, 9.8 Megapixel;
Focus
0. 6/1.5mm
Frequency
100kHz
Photography (Mas)
0.1-500mas
Photography (Kv)
40-125kv
Heat Capacity
300khu
Refrigeration
Semi-Conductor
Trademark
MAYA
Transport Package
Carton/ Wooden Box for Digital X-ray
Specification
CE
Origin
Guangzhou, China
HS Code
9022140090
Model NO.
MY-D047
Detector
17 X 17 in, 9.8 Megapixel;
Focus
0. 6/1.5mm
Frequency
100kHz
Photography (Mas)
0.1-500mas
Photography (Kv)
40-125kv
Heat Capacity
300khu
Refrigeration
Semi-Conductor
Trademark
MAYA
Transport Package
Carton/ Wooden Box for Digital X-ray
Specification
CE
Origin
Guangzhou, China
HS Code
9022140090
My-D047 Digital Radiography System X-ray
My-D047 Digital Radiography System X-ray

Feature:
Configuration and Parameter List for Sickle-Style Arm CCD-DR

UC-arm Digital Radiography System X-ray detector uses KODAK VHD CCD by way of camera shot sensor, KODAK VHD CCD mainly uses in the outer space scientific research, has the superelevation sensitivity and extremely reliability, ultra long service life, This DR system CCD detector compares with ordinary CCD detector has a higher sensitivity and more superior image quality, compares the flat detector has the longer service life and a higher reliability, higher spatial resolution and extremely low use-cost.
Main Use: Used to all over filming inspection: Chest, skull, abdomen, spine, pelvis and limbs etc.

Basic Info.

Type: X Ray Equipment
Classification: Imaging Diagnostic Equipment
Generator Power: 32kw
Image Detector: CCD
Export Markets: Global
Additional Info.

Trademark: ZKML
Packing: Wooden Case
Origin: Beijing, China
HS Code: 9022140090
Production Capacity: Over 3000 Sets/Year

Product Description
UC-Arm Digital X-ray Radiography System(CCD-DR);
Generator: 32KW, 0.1-500mAs;
Tube: 0.6/1.5MM, 40-125KV(standard); 0.6/1.2MM, 40-150KV(optional);
Detector: 17 X 17 in, 9.8 megapixel;
AEC(Automatic Exposure System): Measure the dose of X-ray used in real time operation within the Medical Radiology, Oncology and Chiropractors;
One Button Hand Brake: Doctors only need to press hand brake down and then all the exposure terms are automatically finished.
Product ModelMADR002
Product NameUC-Arm Digital X-ray Radiography System  (CCD-DR)
                                                                                                                                           Specifications
                                                                                                                                                 Generator
CPI High Frequency High Voltage GeneratorMade in Canada
Power32KW
Frequency100KHZ
Photography (mAS)0.1-500mAs
Photography (KV)40-150KV
                                                                                                                                                      Tube
Toshiba Tube (Standard configuration)Made in Japan
Focus0. 6/1.5MM
Photography (KV)40-125KV
Heat Capacity200KHU
VARIAN RAD-14 Tube (Optional)Made in U.S.A
Focus0. 6/1.2MM
Photography (KV)40-150KV
Heat Capacity300KHU
                                                                                                                                        CCD Detector
Image Size17 x 17 inch
Imaging Time≤ 10 S
Transmission Time≤ 2 S
A/D Conversion16 bit/65535 degree
Image pixels≥ 9 Megapixel
Limiting resolution≥3.4 LP/MM
Kodak CCD ChipMade in U.S.A
Blinding ScreenCsI 
RefrigerationSemi-conductor 
Service lifeTheoretically there is no life limit
                                                                                     AEC  (Automatic Exposure Control System)         
Number of measuring fields 3
                                                                                                                                                       Grid
JPI GridMade in Korea
Type Stationary
Size18″×18″
Grid ratio8:1
Density70L/cm
Focus130cm
                                                                                                                                               Collimator
DS CollimatorMade in Korea
Operation methodManual
Indicator light time limit30 seconds±20%
                                                                                                                                                     Radiography Stand 
Type UC-Arm Radiography Stand
Cross arm movement range(55-165)cm±3cm,continuously adjustable
Cross arm rotates around rotation center  (under condition of safe rotation height)(-30 - 120)°±2°
Focus screen distance(100-180)cm±5cm,continuously adjustable
                                                                                                                                                    Table
Length200cm(±3 cm)
Height70cm(±3 cm)
Width65cm(±3 cm)
Locking modemechanical locking
Aluminium equivalent<1.7mmAl
                                                                                Dell Image Capture & Processing Workstation
Lowest standard configuration  Core Duo 2.5GHz, 2GB RAM, Hard disk 320GB,  19 inch LED (1 set), 100M network interface,  DICOM3.0 interface.
                                                                    Automatic Exposure Image - Capture Software System
One button hand brake Doctors only need to press hand brake down  and then all the exposure terms are automatically  finished.
                                                                                          Image Capture and Processing Software
Multifunctional: Manual /automatic window width / window level, preset window width / window       level, positive and negative image turning, image turning, image rotation, image     amplification and roaming, labeling and measuring, splitting, automatic electron    cutting, part amplification, recovering original image.
Image Processing Technique: a) Dynamic scope optimization technique b) High frequency image enhancement technique c) Noise suppression technique automatically d) Edge enhancement technique    
                                                                                                                                Image Printing Function
Manually selecting the target image for printing; Different printing devices, film format and printing pages available; DICOME3.0: @Print SCU; @Worklist SCU; @Storage SCU; @QR SCU; @MPPS SCU.