Zw20-12kv Outdoor Auto Reclosing Vacuum Circuit Break Switch Manufacturer Sf6

China Zw20-12kv Outdoor Auto Reclosing Vacuum Circuit Break Switch Manufacturer Sf6, Find details about China Vacuum Circuit Breaker, Sf6 Circuit Breaker from Zw20-12kv Outdoor Auto Reclosing Vacuum Circuit Break Switch Manufacturer Sf6

Model NO.
ZW20-12F
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
VDE, ISO9001-2000, CE, UL, CB, CCC
Product Name
Sf6 Vacuum Circuit Breaker
Orign of Place
Zhejiang, China
Related Voltage
0-12V
Rated Frequency
50Hz
Rated Current
up to 1000A
Certificate
ISO CCC
OEM
Offered
MOQ
1PCS
Mechanical Life
10000 Times
Net Weight
140 Kg
Trademark
Zhegui Electric
Transport Package
Normal Export Case
Specification
350*785*550
Origin
Zhejiang, China
HS Code
8537209000
Model NO.
ZW20-12F
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
VDE, ISO9001-2000, CE, UL, CB, CCC
Product Name
Sf6 Vacuum Circuit Breaker
Orign of Place
Zhejiang, China
Related Voltage
0-12V
Rated Frequency
50Hz
Rated Current
up to 1000A
Certificate
ISO CCC
OEM
Offered
MOQ
1PCS
Mechanical Life
10000 Times
Net Weight
140 Kg
Trademark
Zhegui Electric
Transport Package
Normal Export Case
Specification
350*785*550
Origin
Zhejiang, China
HS Code
8537209000
PRODUCT DETAILS
 ZW20-12 outdoor AC HV vacuum circuit breaker
Description:

         ZW20-12 outdoor AC HV vacuum boundary circuit breaker (hereinafter referred to as the boundary circuit breaker) is one of our new products. Boundary circuit breaker is a multifunctional intelligent device with the function of vacuum breaker, vacuum load switch, recloser, sectionalized four switches. The main configuration consists of vacuum breaker, CH-40 controller, external voltage transformer (Note: distribution automation line ring network available in bilateral PT) three parts. Products are widely used in 10kV, 13kV city, rural power grid space ring network for disconnecting switch, contact switch, automatic switch device which can implement the ring deployment line load. It can be used as a boundary switch (commonly known as a watchdog) in the branch line of power supply, used as reclosers and sectionalizes in feed overhead distribution network. Boundary circuit breaker with remote management pattern protection and control functions and communication functions. Reliable detection in judgment, mA level zero sequence current and short circuit current between phases, realize the automatic removal of single-phase grounding fault and phase to phase short circuit fault.
       
The main switch is vacuum arc and insulation adopts SF6, N2 mixed gas. The case introducing of Japan, Germany French gas sealing, explosion-proof, insulation system technology, the overall excellent sealing performance. Inside s filled with SF6, N2 mixed gas which does not leak, not affected by the external environment. The spring operating mechanism with miniaturization and performance optimization design, action reliability is much higher than the traditional spring mechanism.

 

 

TECHNICAL PARAMETER
No.nameunitsdata
1The rated voltagekV12
2Rated frequencyHz50
3Rated currentA630
4Rated short circuit breaking currentkA25
5Peak rated closing currentkA50
6Peak rated dynamic stable currentkA50
74S heat stabilized currentkA25
8Rated sequence of operation minute-0.3sOr points-180sOr points
9Rated energy storage motor voltageVAc220
10Maximum/minimum energy storage motor voltageVAC242/187
11Rated closing operating voltageVAc220
12Maximum/minimum closing operating voltageVAC264/143
13Rated switch operating voltageVAc220
14Maximum/minimum switching operating voltageVAC264/143
15Not at the same timems≤2
16The switch is divided at different timesms≤2
17SF6 gas pressure rating (gauge pressure)Mpa0.01
18Rated short circuit current breaking timestime30
19Mechanical lifetime10000

Zw20-12kv Outdoor Auto Reclosing Vacuum Circuit Break Switch Manufacturer Sf6

THE USE OF CONDITIONS

 

1.Altitudes:2000 meters
2.The environment temperature:-30ºC-+55ºC outdoor; the highest annual average temperature 20 ºC, the highes: daily average temperature 30ºC
3.Relative humidity: 95% (25ºC
4.Seismic capacity: horizontal ground acceleration 0.3g, vertical ground acceleration 0.15g, at the same time duration of three sine waves, a safety factor of 1.67
5.Earthquake intensity: 7 degrees
6.The maximum daily temperature difference: 25 ºC
7.The intensity of sunshine (wind speed 0.5m/s): 0.1W/cmi
8.The maximum wind speed: 34m/s
9.The maximum ice thickness
10.Installation position: outdoor, the 10kV overhead line responsibility demarcation point
11.Grounding: neutral non-grounding, arc suppression coil grounding, and low resistance grounding

COMPANY INFORMATION

Zhejiang ZheGui Electric Co., Ltd established in 2013. We are located in Zhejiang with convenient transportation access and developed electrical market. We are group of private enterprises that hold the production license issued by the former ministry of energy and ministry mechanical and electrical engineering. 
    The company has nearly 60 million fixed assets and more than 60 employees, covering 23133 square meters. We are specialized in R&D production of complete switchgear of high and low voltage equipment such as prefabricated substation, distribution cabinet/box, drawer cabinet, ring network cabinet, inflatable cabinet, etc. 
    We owns three CNC bending machine, CNC shearing machine, CNC laser cutting machine and a series of advanced production equipment to further optimized the product structure and improve the efficiency of production. After nearly 7 years of development, it has passed ISO 9001-2000 quality system certification. All items produced by our own factory, so our advantages are: reliable quality and reasonable price. Gather the world's energy to delight your business. It's honorable for Zhegui to share your progress, brilliance and success!

Contact Us

 

 

FAQ