Drnl 1p+N RCD Earth Leakage Circuit Breaker 30mA ELCB 1p+N

China Drnl 1p+N RCD Earth Leakage Circuit Breaker 30mA ELCB 1p+N, Find details about China Earth Leakage Circuit Breaker, ELCB from Drnl 1p+N RCD Earth Leakage Circuit Breaker 30mA ELCB 1p+N

Model NO.
SDRNL
Poles Number
1
Type
Circuit Breaker
Function
Ovp(Overvoltage Protection)
Certification
ISO9001-2000
Color
Red
Poles
1p 2p 3p 4p
Magnetic Tripping Characteristics
6 10 16 20 25 32,40,50,63A
Rated Current(a)
6ka
Rated Voltage Ue
240/415V
Rated Frequency
50/60Hz
Rated Impulse Withstand Voltage (1.2/50)
6000V
Pollution Degree
2
Thermo-Magnetic Release Characteristic
B C D
Protection Degree
IP22
Trademark
suntree
Specification
CE SAA TUV
Origin
China Zhejiang
HS Code
8536620000
Model NO.
SDRNL
Poles Number
1
Type
Circuit Breaker
Function
Ovp(Overvoltage Protection)
Certification
ISO9001-2000
Color
Red
Poles
1p 2p 3p 4p
Magnetic Tripping Characteristics
6 10 16 20 25 32,40,50,63A
Rated Current(a)
6ka
Rated Voltage Ue
240/415V
Rated Frequency
50/60Hz
Rated Impulse Withstand Voltage (1.2/50)
6000V
Pollution Degree
2
Thermo-Magnetic Release Characteristic
B C D
Protection Degree
IP22
Trademark
suntree
Specification
CE SAA TUV
Origin
China Zhejiang
HS Code
8536620000
DRNL 1P+N RCD earth leakage circuit breaker 30ma elcb 1P+N

SDRNL 1P+N RCD
Technical DataSDRNL (SAA)
StandardsAS/NZS 61009 - 1
Magnetic tripping characteristicsB,C
Residual tripping characteristicsA , AC
Rated current(A)6, 10, 16, 25,32
Rated residual current10mA, 30 mA, 100mA
Calibration temperature30ºC
Rated voltage 1P240V
Frequency50/60
Maximum service voltage264
Tripping Duration:Instaneous<0.1s
Power supplyTop or bottom
Selectivity class3
Residual making and breaking capacity2000A
Short circuit capacity6000A
Isolation application (IEC 60947-2)Yes
Insulation resistance (Mohm)1,000
Insulation voltage (V)500
Dielectric rigidity (V)2,500
Vibration resistance1.5g
Endurance (operations) electrical>6,000
mechanical>20,000
Protection degree outsideIP20
inside enclosureIP40
Self extinguishing degree (UL 94)V2
Tropicalisation (IEC 60068-2)+55ºC/95% RH
Operating temperature-5/+55ºC
Storage temperature-25/+70ºC
Terminal capacity (top & bottom) min / max1-16mm
Terminal torque (top / bottom)3
Busbar systemsYes
AccessoriesNo
Dimensions (mm)72(H)81(L)18(W)
Weight (g)105

Features & Advantages:
The slimest 6kA RCBO in this world.
the newest design compared with competitors.
Genuine 6kA fault level
declared after hundreds of seriously passed
test. Suit both residential and commercial
applications.
Top and bottom line and load compatible
newest design for ease of installation.
Two pole safety feature allows switching of
both Active and Neutral contacts.
Active contacts always connect earlier and
break later;
Single module is ideal to save valuable
switchboard space.



Technical Data SNLE 1P+N RCD
StandardsAS/NZS 61009 - 1
Magnetic tripping characteristicsB,C, D
Residual tripping characteristicsAC
Rated current(A)6,10,16,20,25,32
Rated residual current(mA)30, 100,300
Calibration temperature30ºC
Rated voltage 1P240V
Frequency50/60
Maximum service voltage264
Tripping duration:Instaneous<0.1s
Power supplyLine & Load
Selectivity class3
Residual making and breaking capacity2000A
Short circuit capacity10000A
Isolation application (IEC 60947-2)Yes
Insulation resistance (Mohm)1,000
Insulation voltage (V)500
Dielectric rigidity (V)2,500
Vibration resistance1.5g
Endurance (operations) electrical>4,000
mechanical>20,000
Protection degree outsideIP20
inside enclosureIP40
Self extinguishing degree (UL 94)V2
Tropicalisation (IEC 60068-2)+55ºC/95% RH
Operating temperature-5/+55ºC
Storage temperature-25/+70ºC
Terminal capacity (top & bottom) min / max1-16mm
Terminal torque (top / bottom)3
Busbar systemsYes
AccessoriesNo
Dimensions (mm)72(H)81(L)18(W)
Weight (g)105

Construction and Feature
Provides protection against earth fault/leakage current and function
of isolation
Provides protection against over-voltage
Applicable to terminal and pin/fork type busbar connection
Contact position indication
Fire resistant plastic parts endures abnormal heating and strong
impact
Automatically disconnect the circuit when earth fault/leakage
current occurs and exceeds the rated sensitivity.
Independent of power supply and line voltage and free from
external interference, voltage fluctuation.





1) DZ47-63 C45N series MCB
is used in lighting distribution system or motor distribution system for protecting overload and short circuit in the systems.

2)This product is novel in structure, light in weight, reliable and excellent in performance.

3)It has high breaking capacity and can trip quickly. Its case and body are made of highly fire-retardant and shockproof plastic.
4)This product, with long life, is mainly used in AC 50Hz / 60Hz single-pole 240V or
Two / three / four-pole 415V circuit for overload and short circuit protection, as well as infrequent on-and-off switching electric equipment and lighting circuit in normal cases. This product conforms to GB10963 and IEC60898 standards.


Electrical features

Rated current In

A

6A,10A 16A 20A 32A 40A, 50A, 63A

Poles

P

1.2.3.4

Rated voltage Ue

V

240/415

Insulation voltage Ui

V

500

Rated frequency

Hz

50/60

Rated breaking capacity

A

6000,

Rated impulse withstand voltage (1.2/50) Uimp

V

6000

Dielectric test voltage at ind. Freq. for 1 min

Kv

2

Pollution degree

 

2

Thermo-magnetic release characteristic

 

B, C, D

Mechanical features

Electrical life

t

8000

Mechanical life

t

20000

Protection degree

 

IP20

Reference temperature for setting of thermal element

° C

30

Ambient temperature (with daily average ≤ 35 ° C)

° C

-5~+40 (special application please refer to temperature compensation correction)

Storage temperature

° C

-25~+70




DC circuit breaker's Application

SL7-63 Series DC1200V 63A DC Circuit breaker, apply to rating current 63A or less, It is mainly used for the overloading and short circuit protection in DC distribution system equipment and electric equipment. It can be widely used in electric, post, traffic, mining enterprise and different kinds of fields. In present China, our products in the case grade rating voltage is highest compared to the same products.

Standard

Products according IEC60947, GB14048.2, IEC60898.2 AS/NZS60898.1, AS/NZS60898.2, AS/NZ61009
Standard.

Technical DataIEC 898
Standards1P/2P/3P / 4P
PolesC
Magnetic tripping characteristics6 10 16 20 25 32,40,50,63A
Rated current(A)6kA
Rated short-circuit capacity(Icn):DC250V DC550V DC750V DC800V DC1000V DC1200V
Rated voltage6kV
Rated withstand voltage (Uimp):1000
Rated insulation voltage(Ui):Yes
Contact position indication3
Energy limiting class:>2000
Electrical Life:>1500
Mechanical Life:Screw terminal
Connection terminal:Pillar terminal with clamp

 
1~16mm
Connection capacity:Symmetrical DIN rail 35mm
Installation:Panel mounting

 
OF: Auxiliary contact
Accessories:FB: Auxiliary alarm

 
QY: under/over volage protector

 
FL: Shunt release

Overload Characteristic
TestTypeCurrentStart StateTrip / Not-trip
Time Limit
Expected
Result
Note
ac1.05 lnColdt ≥1hNot-trip
 
bc1.30 lnFoollows test at<1hTripThe current will rise to expected value within 5S
cc7 lnColdt ≥0.1sNot-trip
 
dc15lnColdt<0.1sTrip
 



The SL7-63 is a DC circuit breaker dedicated to multi string photovoltaic
installations.
This circuit breaker is designed to protect the cables located between each string
of photovoltaic modules and the photovoltaic inverter against overloads and short
circuits (see application diagram).
Combined with a switch , the SL7-63 will be installed in a string
PV protection enclosure at the end of each string of photovoltaic modules.
It can be locked (by a padlocking device) in OFF position as a safety measure for
removal of the PV inverter.
Since a fault current can flow in the reverse direction to the operating current,
the SL7-63 can detect and protect against any bidirectional current.
To ensure the safety of the installation, it is necessary,
depending on the various types of application, to combine the SL7-63 with:
a residual current device at the AC end
a fault passage detector (insulation monitoring device) at the DC end
an earth protection circuit breaker at the DC end
In all cases, fast action on site will be required to clear the fault
(protection not ensured in the event of a double fault).
SL7-63 is not polarity sensitive: (+) and (-) wires can inversed without any risk.
The SL7-63 is: delivered with three inter-pole barrier to provide increased isolation distance between two adjacent
connectors.

SL7-63 DC MCB Main characteristics
Operating Voltage (Ue)1P=125V DC or 250V DC, 2P=550V DC or 800V DC
3P=750V DC or 800V DC, 4P=1000 V DC or 1200V DC
Rated insulation voltage (Ui)12V-1200 VDC
Breaking capacity (Icu)10 kA
Impulse voltage (Uimp)6 kA
Electrical connectionBy the bottom for In and Out
Number of poles1P, 2P, 3P, 4P
StandardsIEC 60947-2
EN 60947-2
SAA
CE
TUV
Technical data
Position contact indication - suitability for isolation according to IEC/EN 60947-2 standard.
The presence of the green strip guarantees physical opening of the contacts and allows operations
to be performed on the downstream circuit in complete safety.
Increased product service life thanks to fast closing independent of the speed of actuation of the toggle.
Pre-wired product: Input / Output on the same side.
Rated service breaking capacity (Ics)100 % of the Icu
Endurance (O-C)Electrical1,500 cycles (where L/R=2 ms)
Mechanical20, 000 cycles

 

 
Mechanical20, 000 cycles
Degree of pollution2
CategoryA (no delay in accordance with IEC / EN 60947-2 standards)
Degree of protection
(IEC 60529)
IP40
TropicalisationRelative humidity: 95 % at 55°C in accordance with
IEC 60068-2 and GB 14048.2 standards
TemperatureOperating-25°C to 70 °C
Storage-40°C to 85°C


SUNTREE also produce AC circuit breaker,pls kindly check:

DZ47 C45N circuit breaker MCB
Application:
DZ47 C45N series mini circuit breaker are used in lighting distribution system in dusty, commerce and
dwelling, and protecting fractional electric motors, And they also have many merits of high protective
grade (up to IP20), high break capacity, reliable sensitive action, convenient, multiple assembling,
long life etc. They are mainly adapted to the circuit of AC 50HZ, 230V in single pole, 400V in double,
three, four poles for protecting overload and short circuit, Meanwhile, they are also used in turning on
or off the electric apparatus and lighting circuit under the normal condition.
DZ47 C45N Technical Data

Type
DZ47 C45, C45N
Number of poles1P, 2P, 3P, 4P
Rated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A
Breaking Capacity(A)6000/ 4500
Rated Voltage(V)230/400V
Rated Frequency(Hz)50/60Hz
Endurance≥4000
Circumstance Temp.(°C)-5°C ~ +40°C
Electrical Life≥6000
Mechanical Life≥20000
Terminal protectionIP20


C65 DPN circuit breaker MCB
Application:
C65-DPN Series Miniature Circuit Breaker ,
the maximum breaking capacity of up to 4.5kA .
Mainly used in industry, construction, residential, energy and infrastructure construction, etc.
C65 DPN circuit breaker MCB Technical Data

Type
C65-DPN
Number of poles1P
Rated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32A
Breaking Capacity(A)4500
Rated Voltage(V)220/ 240V
Rated Frequency(Hz)50/60Hz
Endurance≥4000
Tripping characteristicsB 3In ~ 5In; C 5In ~ 10In


C65 or C60 circuit breaker MCB
Application:
1)C65 series circuit breaker are used in lighting distribution system or motor distribution system for
protection overload and short-circuit in the system.
The product is neoteric in structure, light in weight, reliable and excellent in performance.
It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastics.
2)The product, with long life, is mainly used in AC 50Hz/60Hz single pole 230V or two, three,
four poles 400V circuit for overload and short-circuit protection as well as for unfrequent on-and-off switching electric equipment and lighting circuit in normal case.
The products comply with IEC 60898.
C65 C60 Technical Data

Type
C65 C60
Number of poles1P, 2P, 3P, 4P
Rated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A
Breaking Capacity(A)6000/ 4500
Rated Voltage(V)230/400V
Rated Frequency(Hz)50/60Hz
Endurance≥4000
Circumstance Temp.(°C)-5°C ~ +40°C
Electrical Life≥6000
Mechanical Life≥20000
Terminal protectionIP20


NC100 circuit breaker MCB
Application:
1)NC100 Series Miniature Circuit Breaker High Breaking Capacity is a small circuit breaker,
the maximum breaking capacity of up to 36kA Include NC100H/NC125H Miniature Circuit Breaker,
NC100LS small leakage protection circuit breaker and vigi NC100 accessories, etc.
2)Mainly used in industry, construction, residential, energy and infrastructure construction, etc.
NC100 Technical Data

Type
NC100
Number of poles1P, 2P, 3P, 4P
Rated Current(A)32, 40, 50, 63, 80, 100, 125A
Breaking Capacity(A)10000
Rated Voltage(V)230/400V
Rated Frequency(Hz)50/60Hz
Endurance≥4000
Circumstance Temp.(°C)-5°C ~ +40°C
Electrical Life≥6000
Mechanical Life≥20000
Terminal protectionIP20


SL7 AC Mini Circuit Breaker
Application:

1)SL7 Circuit Breaker is applicable to protecting from overload and short circuit in the circuit of AC
50/60Hz, Rated voltage 230/400V, rated current 63A, it also can be used in switch the infrequent
operation of the circuit under normal conditions. It's mainly used in industry, commerce, high-rise buildings and residential houses and so on.
2)The Circuit breaker conforms to the requirement of overcurrent protective circuit breaker used in
home and similar fields of IEC60898:1995, IEC60947, GB10963-1999 CE
SAA TUV etc. standards, It has attained the electrical equipment safety certificate.
SL7 AC Mini Circuit Breaker Technical Data

Type
SL7
Number of poles1P, 2P, 3P, 4P
Rated Current(A)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A
Breaking Capacity(Icu)6KA/ 10KA
Breaking capacity of rated operating short circuit(Ics)7500A
Rated Voltage(V)230/400V
Rated Frequency(Hz)50/60Hz
Circumstance Temp.(°C)-5°C ~ +40°C
Electrical Life≥8000
Mechanical Life≥20000
Type and tripping current scope of instantaneous releaseB 3In ~ 5In; C 5In ~ 10In; D 10In ~ 50In
Terminal protectionIP20