Shallow medium filter Drinking water pretreatment
Multimedia Sand Filters
Following multi-layer filtration, Multimedia Sand Filters are most recommended systems to remove suspended particles, color, odor and iron from ground water and wastewater. Multimedia filtration works on pressurized filtration process, where three layers of filter media are used for fine particle removal approximately 5 to 25 microns. As compared to conventional sand filters, multimedia filters offer superior filtration quality, longer filtration cycles and lower water consumption during backwash; hence, these filters offer a flexible and feature-rich way to reduce the amount of suspended solids and turbidity in feed water. These multimedia filters are mostly used as pretreatment to reverse osmosis, DM and softener.
Specification
Available in Vertical & Horizontal
Designed to meet the stringent requirements of clients
Removes particles down to 15-20 micron.
Depth filtration principle
Well designed bed collection system
Operate in optimum velocity require
High removal of suspended solids.
Material of construction MS/FRP/MSRL/SS
Designed as per ASME or IS
Well designed collection system
Well designed distribution system
High end water quality
Shallow medium filter Applications:
Drinking water pretreatment
Swimming pool, Jacuzzi water filtration
Industrial water purification
The residential water supply and return use in water treatment
Agricultural irrigation
Seawater, freshwater aquaculture
How it works( Shallow medium filter):
Flushing filter state:
When the system is filtered state, the unfiltered water through self-developed unique water distributor uniform water distribution, water through the filter to laminar flow conditions within the filler layer (refined grains are quartz sand / garnet). When water flows over the packing layer, impurities are trapped in the filler layer. Bottom of the filter with multiple evenly distributed catchment, the filtered water and leads to uniformly collect, advection filter, the filter can filter at high flow rates, can achieve better filtering results
Backwashing state:
With the impurities accumulate in the filler layer continuously, the internal pressure head losses will continue to grow. When the inlet, the pressure head loss reaches the set value, the system will automatically activate the constant pressure device to switch to backwash the state, when the end of this table backwash, water valve to change direction in order to achieve one by one water backwash, cleaning easier accumulate up impurities.
When the system is in state anti-washing, filtering continues, which should be the standard unit backwash sand filter tank is not, the system of other standard sand tank still in the filter unit. Filtered clean water part of the standard unit used to backwash the sand tank, the rest are still sent to the user Department. Backwash water through the backwash outlet water valve has been discharged. Sand-cylinder high-speed automatic and efficient filtration system, the special design enables the catchment between the filler filler scrub each other to maximize the efficiency of backwashing, the backwash water to reduce the required (clean water), and when the backwash phenomenon is not expected to run. A standard unit of sand backwash tank is 2 minutes, the end of the backwash, the standard unit of sand-cylinder internal pressure head loss is reduced to a reasonable range, given the constant pressure device recovery signal, filtered water valve back to the state, under a standard sand-cylinder unit backwashing is ready to enter the state. Shallow medium filter Equipment installation instructions:
1. The connection for equipment inlet/outlet water pipe and drainage pipe with system is standard flange connection.
2. Pre-installed pressure gauge on inlet and outlet pipe;Drainage pipes increased regulation valves and observation tube.
3. Pre-installed manual valve on inlet and outlet pipe, to ensure that the sewage smooth;
4. Equipment installation at 200mm high cement platform without the basis of embedded, need 220V50Hz power outlet (power controller) nearby.
Technical Parameters:
Specifications:
Model | TANK SIZE (mm) | TOTAL HIGH (mm) | FLOW RATE (m3/hr) | INLET AND OUTLET (mm) |
YLD-MF-500 | 500*1500 | 2350 | ~2 | DN32 |
YLD-MF-600 | 600*1500 | 2380 | 2-3 | DN32 |
YLD-MF-700 | 700*1500 | 2400 | ~4 | DN40 |
YLD-MF-800 | 800*1500 | 2400 | ~5 | DN40 |
YLD-MF-900 | 900*1500 | 2500 | ~6 | DN50 |
YLD-MF-1000 | 1000*1500 | 2600 | ~8 | DN50 |
YLD-MF-1200 | 1200*1500 | 2700 | ~11 | DN65 |
YLD-MF-1400 | 1400*1500 | 2800 | ~15 | DN65 |
YLD-MF-1500 | 1500*1500 | 2850 | ~18 | DN65 |
YLD-MF-1600 | 1600*1500 | 2900 | ~20 | DN80 |
YLD-MF-1800 | 1800*1500 1800*1800 | 3000 | ~25 | DN80 |
YLD-MF-2000 | 2000*1500 | 3100 | ~30 | DN100 |
YLD-MF-2200 | 2200*1500 | 3180 | ~38 | DN100 |
YLD-MF-2400 | 2400*1500 | 3330 | ~45 | DN100 |
YLD-MF-2500 | 2500*1500 | 3380 | ~50 | DN100 |
YLD-MF-2600 | 2600*1500 | 3430 | ~55 | DN125 |
YLD-MF-2800 | 2800*1500 | 3530 | ~60 | DN125 |
YLD-MF-3000 | 3000*1500 | 3630 | 70-80 | DN125 |
YLD-MF-3200 | 3200*1500 | 3730 | 80~100 | DN150 |
FAQ:
01. how small a solid needs to be removed,
02. how dirty the water is,
03. how the water will be used once it is filtered,
04. and the source of backwash water needed to clean the filters.