AC220V/DC24V/1A FM200 Automatic Fire Extinguishing System

China AC220V/DC24V/1A FM200 Automatic Fire Extinguishing System, Find details about China Fire Suppression System, FM200 Fire Suppression System from AC220V/DC24V/1A FM200 Automatic Fire Extinguishing System

Model NO.
AW-FM200
Effective Range
9m
Retirement Life
5 Years
Dry Powder Type
FM200 Agnet
Power Source
Gas Fire Extinguisher
Trademark
Asenware
Transport Package
Wooden Box
Specification
20L-180L
Origin
Made in China
Model NO.
AW-FM200
Effective Range
9m
Retirement Life
5 Years
Dry Powder Type
FM200 Agnet
Power Source
Gas Fire Extinguisher
Trademark
Asenware
Transport Package
Wooden Box
Specification
20L-180L
Origin
Made in China

 

Product Description

 HFC227 Fire Protection systems    FM200 Gas Description 

HFC227 fire protection systems, FM200 gas is an engineered system  utilizing a fixed nozzle agent distribution network. The system is designed and installed in accordance with the National Fire Protection Association (NFPA) Standard 2001, "Clean Agent Fire Extinguishing Systems." When properly designed, the FM-200 system will suppress surface burning fire in Class A, B, and C hazards.

The clean agent fire extinguishing system shall perform as outlined in the following sub-sections.
A. Achieve a 6.25% (v/v) extinguishing concentration for Class A (Surface Type Fires) hazards.

B. Achieve a 8.70% (v/v) or greater, as required, extinguishing concentration for Class B (Flammable Liquids) hazards.

C. Achieve a 7.00% (v/v) extinguishing concentration for Class C (Energized Electrical Equipment) hazards.

D. Within 10 seconds, the clean agent fire extinguishing system shall discharge 95% of the required suppression agent mass.

E. The clean agent HFC227 fire protection systems , FM200 gas  fire extinguishing system shall consist of one or more Asenware Fire Systems agent cylinders and related equipment. The cylinders may be either connected to a discharge pipe arrangement separately or connected to a common manifold and discharge pipe arrangement. The agent cylinders shall be filled with FM-200, and super pressurized with dry nitrogen to a working pressure of 360 PSIG at 70°F (24.8 bar gauge at 21°C).

Fm200 system; FM200 fire extinguisher

 

The Technical Parameters of FM200 System

 

Product Name  AC220V/DC24V/1A FM200 automatic fire extinguishing system
BrandASENWARE
ModelAW-FM200
Filling Pressure 4.2 Mpa

Extinguishing Agent
Release Time

≤10s

Extinguishing Agent
Filling Density

≤950kg/m3

Valve Drive Air Pressure

6.0±1.0 Mpa(20ºC)

System Power Supply

AC220V/DC24V/1A

System Working
Environment Temperature

-10ºC~55ºC

System Protection Limits Area

The largest single area 800m ²;
Volume : the largest single area 3600m ³

System Start-up Mode

Automatic system startup ,
electrical manual ,
mechanical emergency manual

Storage Bottle Volume

40L, 70L, 100L, 120L, 150L

AC220V/DC24V/1A FM200 Automatic Fire Extinguishing System

 

 Fm200 system; FM200 fire extinguisher

 

Product Images

AC220V/DC24V/1A FM200 Automatic Fire Extinguishing System
 

AC220V/DC24V/1A FM200 Automatic Fire Extinguishing System

AC220V/DC24V/1A FM200 Automatic Fire Extinguishing System

Our project:
AC220V/DC24V/1A FM200 Automatic Fire Extinguishing System
 

Company Information:

ASENWARE is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provider since 2005.

Driven by a commitment to sound operations, ongoing innovation, and open collaboration, we have established a competitive fire safety products line include addressable fire alarm system, conventional fire alarm system, central monitoring emergency light system, fire telephone and emergency audio system, fire pump, fire hose and gas suppression system.

Our fire safety products ,solutions and services are used in over 100 countries.
With over 200 employees work in United Kingdom-Marketing Center, China-R&D and Supply Chain Center and Bangladesh-Manufacture
Center, ASENWARE is committed to design and manufacture the best fire safety products to reduce the risk of fire, and support theworld to be more safe and more comfortable.

AC220V/DC24V/1A FM200 Automatic Fire Extinguishing SystemAC220V/DC24V/1A FM200 Automatic Fire Extinguishing System
AC220V/DC24V/1A FM200 Automatic Fire Extinguishing SystemAC220V/DC24V/1A FM200 Automatic Fire Extinguishing System






Exhibition:
AC220V/DC24V/1A FM200 Automatic Fire Extinguishing System


Certification:AC220V/DC24V/1A FM200 Automatic Fire Extinguishing System

Our Services:

* Over 15 years' experience.
* Prompt response.
* OEM & ODM available.
* Support factory inspection.
* Standard qulity control system.
* Different choices of payment and delivery.
* Independant R&D dept, designing dept,to meet your special need.
* Whole set of technical supports and with abroad projects experience.
* We are manufacturer, offer better price better service.
* Direct control on materials, production status, quality checking.
* Sample order, customized order, bulk order are supported.
* Reliable after-sales service, with one year waranty.


Contact:
Lily Huang

 Shenzhen Asenware Test&Control Technology Co.,Ltd
Website:asenware.en.made-in-china.com
Factory Add: 4F,10#, Xingye Rd., Huoju District, Zhongshan City, Guangdong
Marketing Center AddR: 26H, Building D, Shihong Garden, Fanshen Rd, Baoan, Shenzhen