China ASTM D4294 Gd-17040 X-ray Fluorescence Sulfur Content Tester / Oil Automatic Sulfur Analyzer, Find details about China Sulfur-in-Oil Analyzer, Oil Automatic Sulfur Analyzer from ASTM D4294 Gd-17040 X-ray Fluorescence Sulfur Content Tester / Oil Automatic Sulfur Analyzer
ASTM D4294 GD-17040 X-ray Fluorescence Sulfur-in-Oil Analyzer/Oil Automatic Sulfur Analyzer
Sulfur is an element found in crude oil and petroleum products, and it is considered an undesirable contaminant. Because it will generates the sulfur oxides when burn it. Consequently, most finished petroleum products have a limit on how much sulfur they can contain, making sulfur removal an important part of the overall refinery process. Sulfur can also harm some of the catalysts used in refining process units so it must be removed from some intermediate streams before they can be fed to a conversion unit
ASTM D4294 X-ray Fluorescence Sulfur-in-Oil Analyzer is specially designed to determine sulfur content in the petroleum products.
ASTM D4294 X-ray Fluorescence Sulfur-in-Oil Analyzer can meet the requirements of ASTM D4294-02.
ASTM D4294 X-ray Fluorescence Sulfur-in-Oil Analyzer provides a measure to determine sulfur content during petroleum or petrchemical production prcess.
Application:
1. ASTM D4294 X-ray Fluorescence Sulfur-in-Oil Analyzer can be used to determine mass% of total sulfur in the crude petroleum, petroleum, heavy oil, diesel oil, gasoline, and naphtha.
2. ASTM D4294 X-ray Fluorescence Sulfur-in-Oil Analyzer can be used to determine total sulfur content in the products of coal chemical industry, such as primary benzene.
3. ASTM D4294 X-ray Fluorescence Sulfur-in-Oil Analyzer can be used to determine total sulfur or sulfide in other liquid or solid powder samples.
Specifications:
Product name | Gd-17040 X-ray Fluorescence Sulfur Content Tester | |
Measuring range | 20 ppm to 5% | |
Repeatability (r) | <0.02894 (X+0.1691) | |
Reproducibility (R) | <0.1215(X+0.5555) | |
Detection limit | 7 ppm | |
Oil sample quantity | 2.5 ml (it is equal to sample depth of 4.5 mm) | |
Measurement time | it can preset 60, 120, 240, 300, and 600 s at random | |
Repeat times | can set 2, 3, 5, 10, and 50 at random | |
Calibration curve numbers | it can save 9 calibration curves. 5 pieces of them are unary linear equation and 4 pieces of them are unary quadratic equation. | |
Working condition | Ambient temperature | 5~40ºC |
Relative humidity | ≤85% (30 ºC) | |
Power supply | AC 220V±20V, 50 Hz; Rated power: 30 W | |
Dimension and weight | 468mm*368mm*136mm; 13 kg |
Parameter | GD-380B | GD-387 | GD-17040 | GD-0689 |
Standards | GB/T 380, ASTM D1266 | GB/T 387, ASTM D1551 | GB/T 17040, GB/T11140, ASTM D4294 | ISO 20846,ASTM D5453,ASTM D4629,ASTM D5762, ASTM D6069 |
Test sample | Light oils, such as gasoline, kerosene | Dark oils which sulfur content >0.1% | Petroleum oil with sulfur content of 20ppm to 100% | Petroleum oil with sulfur content of 5ppm to 100% |
Test method | Lamp method | Quartz tube method | X-ray fluorescence (XRF)method | Ultraviolet fluorescence method |
Dimension | 3800*320*600mm | 530*400*670mm | 468*368*136mm | Host:305*460*440mm Temp controller:550*460*440mm |
Working temperature | 5~40ºC | 5~40ºC | 5~40ºC | 5~40ºC |
Relative humidity | ≤85%(30ºC) | ≤85%(30ºC) | ≤85%(30ºC) | ≤85%(30ºC) |
Power suply | AC220V ±20V, 50Hz | AC220V ±20V, 50Hz | AC220V ±20V, 50Hz | AC220V ±20V, 50Hz |