China Inverter AC Charger Charger Low Frequency Inverter 96kw 384V Inverter, Find details about China off Grid Solar System, 96kw 384V Inverter from Inverter AC Charger Charger Low Frequency Inverter 96kw 384V Inverter
Product Parameters | |||||||||
Specification | |||||||||
Model: SGT | 4KVA | 6KVA | 7KVA | 8KVA | 10KVA | 15KVA | 20KVA | 25KVA | |
Rated Power | 3.2KW | 4.8KW | 5.6KW | 6.4KW | 8KW | 12KW | 16KW | 20KW | |
Battery Voltage | 48/96/192VDC | 96/192/384VDC | |||||||
Specification | |||||||||
Model: SGT | 30KVA | 40KVA | 50KVA | 60KVA | 80KVA | 100KVA | 125KVA | 150KVA | |
Rated Power | 24KW | 32KW | 40KW | 48KW | 64KW | 80KW | 100KW | 120KW | |
Battery Voltage | 192/384VDC | 384VDC | |||||||
Parameter | |||||||||
Input | AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) | |||||||
AC Input Frequency Range | 45Hz-65Hz | ||||||||
Phase | 3/N/PE | ||||||||
Output | Efficiency | ≥85% | |||||||
Output Voltage(Battery Mode) | 380Vac/400Vac±10%(customized 190Vac/200Vac) | ||||||||
Output Frequency(Battery Mode) | 50/60Hz ±1% | ||||||||
Output Wave(Battery Mode) | Pure Sine wave | ||||||||
THD | liner load≤3% | ||||||||
AC Output Voltage Range | Conforming to AC input | ||||||||
AC Output Frequency Range | Conforming to AC input | ||||||||
Phase | 3/N/PE | ||||||||
Inside Solar Controller (optional) | Charging Mode | MPPT or PWM | |||||||
Charging Current | 12V/24V/48V System:10A,20A,30A,40A,50A,60A; 96V/192V/384V System:50A,100A,150A,200A | ||||||||
PV Input Voltage Range | 12V System:15V-44V;24V System:30V-44V;48V System:60V-88V; 96V System:120V-176V;192V System:240V-352V;384V System:480V-704V | ||||||||
Max PV Input Voltage (At 25°C) | 12V/24V System:50V;48V System:100V;96V System:200V;192V System:400V;384V System:750V | ||||||||
PV Array Maximum Power | 12V System:140W,280W,420W,560W,700W,840W;24V System:280W,360W,840W,1120W,1400W,1680W; 48V System:560W,1120W,1680W,1120W,2240W,3360W;96V System:5.6KW,11.2KW,8.4KW*2,11.2KW*2 192V System:11.2KW,22.4KW,16.8KW*2,22.4KW*2;384V System:22.4KW,44.8KW,33.6KW*2,44.8KW*2 | ||||||||
Battery | DC input voltage range | 10.5-17V DC/Single battery | |||||||
Battery low voltage alarm | 11V/Single battery | ||||||||
Battery low voltage protection | 10.5V DC/Single battery | ||||||||
Battery high voltage alarm | 15V/Single battery | ||||||||
Battery high voltage protection | 17VDC/Single battery | ||||||||
Battery Type | U0: Gel U.S.A / U1: A.G.M.1 /U2: A.G.M.2 / U3: Sealed lead Acid / U4: Gel European / U5: Open lead Acid / U6: Calcuim(open) / U7: Sulphation cycle | ||||||||
Working Mode | Battery First/AC First/Saving Energy Mode | ||||||||
AC Charging current(selectable) | 0~45A | ||||||||
Transfer Time | ≤4ms | ||||||||
Display | LCD | ||||||||
Thermal method | Forced air cooling | ||||||||
Protection | Over-load / Over-discharge / Short circuit / High and low temperayure | ||||||||
Communication | RS232/RS485/APP/SNMP/GSM (Optional) | ||||||||
Environment | Temperature | -10ºC~40ºC | |||||||
Height | 2000m(Less load when height over) | ||||||||
Noise | ≤65dB | ||||||||
Humidity | 0%~95%(No condense) | ||||||||
Note:All specifications are subject to charge without prior notice |