Inverter AC Charger Charger Low Frequency Inverter 96kw 384V Inverter

China Inverter AC Charger Charger Low Frequency Inverter 96kw 384V Inverter, Find details about China off Grid Solar System, 96kw 384V Inverter from Inverter AC Charger Charger Low Frequency Inverter 96kw 384V Inverter

Model NO.
SGT-96KW
Nature of Wave String
Sine Wave Inverter
Type
DC/AC Inverters
Dimension
87.5*72*138cm
N.W./Unit(Kg)
552kg
Meas
98*82.5*156cm
G.W./CTN(Kg)
592kg
Trademark
SUG
Transport Package
Carton
Specification
SGT-96KW
Origin
China
HS Code
8504403090
Model NO.
SGT-96KW
Nature of Wave String
Sine Wave Inverter
Type
DC/AC Inverters
Dimension
87.5*72*138cm
N.W./Unit(Kg)
552kg
Meas
98*82.5*156cm
G.W./CTN(Kg)
592kg
Trademark
SUG
Transport Package
Carton
Specification
SGT-96KW
Origin
China
HS Code
8504403090
Inverter AC Charger Charger Low Frequency Inverter 96kw 384V Inverter
Inverter AC Charger Charger Low Frequency Inverter 96kw 384V InverterInverter AC Charger Charger Low Frequency Inverter 96kw 384V InverterInverter AC Charger Charger Low Frequency Inverter 96kw 384V InverterInverter AC Charger Charger Low Frequency Inverter 96kw 384V InverterInverter AC Charger Charger Low Frequency Inverter 96kw 384V InverterInverter AC Charger Charger Low Frequency Inverter 96kw 384V Inverter
Inverter AC Charger Charger Low Frequency Inverter 96kw 384V InverterInverter AC Charger Charger Low Frequency Inverter 96kw 384V Inverter
Product Parameters
          
Specification
Model: SGT4KVA6KVA7KVA8KVA10KVA15KVA20KVA25KVA
Rated Power3.2KW4.8KW5.6KW6.4KW8KW12KW16KW20KW
Battery Voltage48/96/192VDC96/192/384VDC
Specification
Model: SGT30KVA40KVA50KVA60KVA80KVA100KVA125KVA150KVA
Rated Power24KW32KW40KW48KW64KW80KW100KW120KW
Battery Voltage192/384VDC384VDC
Parameter
InputAC Input Voltage Range380Vac/400Vac±10%(customized 190Vac/200Vac)
AC Input Frequency Range45Hz-65Hz
Phase3/N/PE
OutputEfficiency≥85%
Output Voltage(Battery Mode)380Vac/400Vac±10%(customized 190Vac/200Vac)
Output Frequency(Battery Mode)50/60Hz ±1%
Output Wave(Battery Mode)Pure Sine wave
THDliner load≤3%
AC Output Voltage RangeConforming to AC input
AC Output Frequency RangeConforming to AC input
Phase3/N/PE
Inside Solar
Controller
(optional)
Charging ModeMPPT or PWM
Charging Current12V/24V/48V System:10A,20A,30A,40A,50A,60A; 96V/192V/384V System:50A,100A,150A,200A
PV Input Voltage Range12V System:15V-44V;24V System:30V-44V;48V System:60V-88V;
96V System:120V-176V;192V System:240V-352V;384V System:480V-704V
Max PV Input Voltage
(At 25°C)
12V/24V System:50V;48V System:100V;96V System:200V;192V System:400V;384V System:750V
PV Array Maximum Power12V System:140W,280W,420W,560W,700W,840W;24V System:280W,360W,840W,1120W,1400W,1680W;
48V System:560W,1120W,1680W,1120W,2240W,3360W;96V System:5.6KW,11.2KW,8.4KW*2,11.2KW*2
192V System:11.2KW,22.4KW,16.8KW*2,22.4KW*2;384V System:22.4KW,44.8KW,33.6KW*2,44.8KW*2
BatteryDC input voltage range10.5-17V DC/Single battery
Battery low voltage alarm11V/Single battery
Battery low voltage protection10.5V DC/Single battery
Battery high voltage alarm15V/Single battery
Battery high voltage protection17VDC/Single battery
Battery TypeU0: Gel U.S.A / U1: A.G.M.1  /U2:  A.G.M.2 / U3: Sealed lead Acid / U4: Gel European /
 U5: Open lead Acid / U6: Calcuim(open) / U7: Sulphation cycle
Working ModeBattery First/AC First/Saving Energy Mode
AC Charging current(selectable)0~45A
Transfer Time≤4ms
DisplayLCD
Thermal methodForced air cooling
ProtectionOver-load / Over-discharge / Short circuit / High and low temperayure
CommunicationRS232/RS485/APP/SNMP/GSM (Optional)
EnvironmentTemperature -10ºC~40ºC
Height2000m(Less load when height over)
Noise≤65dB
Humidity0%~95%(No condense)
Note:All specifications are subject to charge without prior notice