0.6/1kv LV Copper Conductor PVC Insulation Power Cable Outdoor Underground Steel Type Armored XLPE

China 0.6/1kv LV Copper Conductor PVC Insulation Power Cable Outdoor Underground Steel Type Armored XLPE, Find details about China Coaxial Cable, Copper Wire from 0.6/1kv LV Copper Conductor PVC Insulation Power Cable Outdoor Underground Steel Type Armored XLPE

Model NO.
VV NYY
Wire Core Material
Aluminum
Certification
ISO, CCC, CE, RoHS, UL
Model
YJV
Application Voltage
8.7/10kv (15kv)
Transport Package
Standard Export Wooden Reel or Coil
Specification
8.7/10kV YJV/YJLV/YJV22/YJLV22/YJV32/YJLV32
Origin
China
HS Code
8544492100
Model NO.
VV NYY
Wire Core Material
Aluminum
Certification
ISO, CCC, CE, RoHS, UL
Model
YJV
Application Voltage
8.7/10kv (15kv)
Transport Package
Standard Export Wooden Reel or Coil
Specification
8.7/10kV YJV/YJLV/YJV22/YJLV22/YJV32/YJLV32
Origin
China
HS Code
8544492100
Product Description

0.6/1kV LV Copper Conductor PVC Insulated Power Cable

 

Application of Copper Conductor PVC Insulated Power Cable

 

PVC insulated power cables for rated voltages up to 0.6/1 kV are fit for AC 50Hz distribution lines for the same rated voltages. The mechanical and electrical properties of these cables are accordant with GB/T12706-2008 ( Power cables extruded insulation and their accessories of rated voltagesl kV(Umz1.2kV)up to ) and IEC-60502-1 :2004 ( Extruded insulation power cables and appendites for rated voltages 1kV up to 30kV) 

 

Characteristics of Copper Conductor PVC Insulated Power Cable

1. Rated Voltage: 0.6/1kV 

2. Max.permissible operating temperature of conductor is 70ºC.

3. Conductor short-circuit temperature shall not exceed 250ºC Max. sustaining period shall not exceed 5 seconds.

4. Bending Radius

     Bending radius of single core cable:20(D+d)±5%

     Bending radius of multi core cable:15(D+d)±5%

     D-Actual outer diameter of cable sample(mm);

      d-Actual diameter of the conductor(mm).

5. No restriction of level difference along the route for installation.

6. Installation temperature shall be heated when ambient temperature is below 0ºC

 

Type, Description & Application Occasion of PVC Insulated Power Cable

 

  Type         Description                 Application
VV
VLV
PVC insulated PVC   sheathed power cable For   laying in doors,inducts and in tunnels,but unable to bear pressure and   external mechanial forces 
VV22
VLV22
PVC   insulated steel tape armoured PVC sheathed power cable For   laying in doors, in tunnels and direct in ground, able to bearpressure and   external mechanial forces 
VV32
VLV32
PVC   insulated thin steel wire armoured PVC sheathed power cable For   laying in doors,in wells,under water,able to bear overlain axis pulling  force. 
VV42
VLV42
PVC   insulated thick steel wire armoured PVC sheathed power cable For   laying down wells and under water,able to bear certain pulling force. 
NH ZR-VV
ZR-VLV
PVC   insulated PVC sheathed flame fire power cable For   laying in doors,inducts and in tunnels,but unable to bear pullingforce and   pressure. On the sites where fire
occurs freequently. 
NH ZR-VV22
ZR-VLV22
PVC   insulated steel tape armoured PVC sheathed flame fireretardant power   cable For   laying in doors,in tunnels and direct in ground, able to bear pulling force   and pressure. On the sites
where fire occurs freequently. 
NH ZR-VV32
ZR-VLV32 
PVC   insulated thin steel wire armoured PVC sheathed flame fireretardant power   cable For   laying in doors,in wells,under water,able to bear overlain axis pulling  force. On the sites where fire oc- freequently course. 
NH ZR-VV42
ZR-VLV42 
PVC   insulated thick steel wire armoured PVC sheathed flame fireretardant power   cable For   laying down wells and under water,able to bear certain pulling force. On the   sites where fire occurs
freequently. 

 

Structure of Copper Conductor PVC Insulated Power Cable

Conductor

--Annealed Copper (Class 1 or 2)

Insulation

--PVC (Polyvinyl Chloride)

Sheath

--PVC (Polyvinyl Chloride)


Product Detail

0.6/1kv LV Copper Conductor PVC Insulation Power Cable Outdoor Underground Steel Type Armored XLPE

Standard 

IEC 60502-1   GB/T 12706-1

 

Dimension 

0.6/1kV Copper Conductor PVC Insulated Power Cable

Nominal AreaReference DiameterApproximate Weight
kg/km
Nominal AreaReference   DiameterApproximate Weight
kg/km
mm2mmVVmm2mmVV
1*46.8872*413.1229
1*67.21102*614.1283
1*1081652*1016.7403
1*168.92202*1618.8551
1*2510.43452*2517.4620
1*3511.54242*3519920
1*50135552*5021.61264
1*70147702*7024.21686
1*9516.410402*9527.42237
1*12017.812902*12029.82753
1*15020.615902*15032.83400
1*18522.519442*18536.24189
1*24024.925102*24040.65373
1*30027.33176   
1*40034.14160   
1*50036.65195   
1*63040.26451   
Nominal AreaReference DiameterApproximate Weight
kg/km
Nominal AreaReference DiameterApproximate Weight
kg/km
mm2mmVVmm2mmVV
3*4142883*4+1*2.514.6328
3*615.13633*6+1*416.1428
3*1017.95303*10+1*618.7614
3*1620.27413*16+1*1021.4876
3*2519.88403*25+1*1621.11202
3*3521.812833*35+1*1623.31524
3*502517783*50+1*2527.12147
3*7028.224073*70+1*3530.32871
3*9532.132113*95+1*5034.83868
3*12034.939663*120+1*7037.64825
3*15038.849293*150+1*7041.75806
3*18542.860563*185+1*9546.27214
3*24047.977743*240+1*12051.89197
3*30053.296583*300+1*15057.311415
Nominal AreaReference Diameter

Approximate Weight

kg/km

Nominal AreaReference DiameterApproximate Weight
kg/km
mm2mmVVmm2mmVV
4*415.23553*4+2*1.514.3324
4*616.44533*6+2*416.1440
4*1019.56703*10+2*618.7635
4*1622.19473*16+2*1021.8926
4*2522.213023*25+2*1623.31333
4*3524.417043*35+2*1624.71635
4*5028.423753*50+2*2528.32255
4*703231953*70+2*35323135
4*9536.542603*95+2*5036.74217
4*12039.752503*120+2*7040.75417
4*15044.365373*150+2*7043.76303
4*18548.980293*185+2*9549.28024
4*24054.8102973*240+2*1205510314
4*30060.6127693*300+2*15060.812817
Nominal AreaReference DiameterApproximate Weight
kg/km
Nominal AreaReference Diameter

Approximate Weig

kg/km

mm2mmVVmm2mmVV
4*4+1*2.514.83485*2.513.4266
4*6+1*416.44655*414.6386
4*10+1*619.46865*616505
4*16+1*1022.49925*1019.1760
4*25+1*1623.513625*1622.61090
4*35+11625.117515*2527.41598
4*50+1*2529.524735*3530.52134
4*70+1*3532.933675*5035.22848
4*95+1*5037.345125*7039.83980
4*120+1*7041.257095*9545.65386
4*150+1*7045.16921   
4*185+1*9549.88592   
4*240+1*12056.211018   
4*300+1*15062.113681   



Max. D.C. resistance of cable conductor at 20ºC

Rated cross area (mm2)

0.5

0.75

1.0

1.5

2.5

4

6

10

Cu(Ω/km)

Non tinned   

36.0

24.5

18.1

12.1

7.41

4.61

3.08

1.83

Tinned

36.7

24.8

18.2

12.2

7.56

4.70

3.11

1.84

Al  (Ω/km)

/

/

/

18.1

12.1

7.41

4.61

3.08

Rated cross area (mm2)

16

25

35

50

70

95

120

150

Cu   (Ω/km)

Non tinned

1.15

0.727

0.524

0.387

0.268

0.193

0.153

0.124

Tinned

1.16

0.734

0.529

0.391

0.270

0.195

0.154

0.126

Al (Ω/km)

1.91

1.20

0.868

0.641

0.443

0.320

0.253

0.206

Rated cross area (mm2)

185

240

300

400

500

630

800

1000

Cu  (Ω/km)

Non tinned   

0.0991

0.0754

0.0601

0.0470

0.0366

0.0283

0.0221

0.0176

Tinned

0.100

0.0762

0.0607

0.0475

0.0369

0.0286

0.0224

0.0177

Al ( Ω/km)

0.164

0.125

0.100

0.0778

0.0605

0.0469

0.0367

0.0291

 

The current-carrying capacity of 1kV PVC insulates and sheath Power Cable

 

Apply the model number: VV  VLV ;

Limit condition:Environment temperature:250C;Soil  temperature:250C;  Soil thermal receptivity: 1200·cm/W   

 

Conductor

Area

mm2

(A)

The long-term admission current-carrying capacity in   air

(A)

The long-term admission current-carrying capacity in   soil

Cu

Al

Cu

Al

1-core

2-core

3or4  

core

1-core

2-core

3or4  

core

1-core

2-cor

3or4  core

1-core

2-cor

3or4  core

4

41

35

29

31

26

22

56

41

35

43

32

27

6

54

44

38

41

34

29

70

52

44

54

40

34

10

72

60

52

55

46

40

94

69

59

72

53

46

16

97

79

69

74

61

53

124

91

77

95

70

59

25

132

107

93

102

83

72

163

118

101

125

91

78

35

162

124

113

124

95

87

196

139

124

151

107

95

50

204

155

140

157

120

108

241

171

150

185

132

116

70

253

196

175

195

151

135

292

208

184

225

160

141

95

272

238

214

214

182

165

348

257

218

267

191

168

120

356

273

247

276

211

191

392

282

247

305

218

190

150

410

315

293

316

242

225

447

322

283

343

248

218

185

465

356

332

358

274

257

500

360

318

385

278

247

240

552

/

393

425

/

306

582

/

368

447

/

284

300

636

/

452

490

/

352

660

/

417

500

/

317

400

757

/

/

589

/

/

773

/

/

593

/

/

500

886

/

/

680

/

/

876

/

/

670

/

/

 

Workshop
0.6/1kv LV Copper Conductor PVC Insulation Power Cable Outdoor Underground Steel Type Armored XLPE
Produce Process
0.6/1kv LV Copper Conductor PVC Insulation Power Cable Outdoor Underground Steel Type Armored XLPE
Test Equipment
0.6/1kv LV Copper Conductor PVC Insulation Power Cable Outdoor Underground Steel Type Armored XLPE

 
 
Packaging & Shipping

0.6/1kv LV Copper Conductor PVC Insulation Power Cable Outdoor Underground Steel Type Armored XLPE
Related Product
0.6/1kv LV Copper Conductor PVC Insulation Power Cable Outdoor Underground Steel Type Armored XLPE

 

Our Advantages

1.Quickly and professional response
2. 17+ imports and export experiences
3. Excellent quality with reasonable price.
4. Sufficient support for our tendering representatives.
5. OEM service available based on official & legal authorization.
6. Strict quality control system.
7. Faster lead time than our competitors.
8. Cable solutions to your particular requirements.
9. Free sample is available with economic express fee.
10.12 months quality guarantee after delivery.