Solid Insulated switchgear CKG vacuum contactor

China Solid Insulated switchgear CKG vacuum contactor, Find details about China Vacuum Contactor, Distribution Equipment from Solid Insulated switchgear CKG vacuum contactor

Poles Number
1-3
Type
Circuit Breaker
Function
Circuit-Breaker Failure Protection
Certification
ISO9001-2000
Poles Number
1-3
Type
Circuit Breaker
Function
Circuit-Breaker Failure Protection
Certification
ISO9001-2000

 Solid Insulated switchgear CKG vacuum contactor

             

l  CKG-7.2/12 KV series high voltage out door circuit breaker can be used for 50HZ 40. 5kv outdoor high voltage electrical equipment.

l  Attached spring operating structure and electromagnet operating structure can manipulate electric opening and closing in a distance, or accumulate energy for manual operation.

l  The design performance strictly sticks to our national standard GB1984-89 for high voltage alternating current vacuum circuit breaker, and meet the requirements of International Electro technical Commission (IEC) IEC-56 for high voltage alternating current vacuum circuit breaker.

l  Mainly used in controlling and protection of outdoor power transmission and transformation system of 35kv, also in normal operation and short-circuit protection for all kinds of power grid and frequent operation place.

l  Highest system voltages Um related to the rated voltages are defined in IEC 60071-1.

l  These series of VCBs are ceramic pillar type.

l  Vacuum interrupter is installed in upper part of ceramic insulator.

l  It has characteristics of well tightness and high temperature endurance, non-combustion and non-exploration, easy mounting, anti-aging and long service life.  

 

Ambient condition

1. Altitude: up to 2500m

2. Ambient temperature: max +50°C min -35°C

3. Maximum daily average temperature °C 40

4. Wind pressure: ≤700Pa (equals to wind speed 37.5m/s)

5. Earthquake intensity: ≤8 degree (as per terms UBN-97: Zone 1)

6. Air contamination degree:  degree

7. Max daily temperature variation: ≤25°C

8. Maximum solar radiation: ≤1035 W/m²

9. Isokeraunic level: ≤70

10. Average rainfall annually: ≤1400 mm/a

 

Dimensions:
Solid Insulated switchgear CKG vacuum contactor
Solid Insulated switchgear CKG vacuum contactor
 

Solid Insulated switchgear CKG vacuum contactorSolid Insulated switchgear CKG vacuum contactor
Solid Insulated switchgear CKG vacuum contactor
Solid Insulated switchgear CKG vacuum contactor
Solid Insulated switchgear CKG vacuum contactor
Solid Insulated switchgear CKG vacuum contactor
Solid Insulated switchgear CKG vacuum contactor
Solid Insulated switchgear CKG vacuum contactorSolid Insulated switchgear CKG vacuum contactor

Company website:

http://feiteelectric.en.made-in-china.com

 

Comtact person:Willow Chen

 

 

Professional, Creative, Good quality and Excellent service

 

Welcome your inquiry, Welcome our cooperation!