36kv Permanent Magnet High Voltage Vacuum Contactor (JCZ6)

China 36kv Permanent Magnet High Voltage Vacuum Contactor (JCZ6), Find details about China Contactor, Vacuum Contactor from 36kv Permanent Magnet High Voltage Vacuum Contactor (JCZ6)

Model NO.
JCZ6
Power-Frequency Withstand Voltage
95kv
Clearance Between Open Contacts
0.1mm-3.1mm
Mechanical Life
100,000times
Electrical Life
50,000times
Over Travel
Min:2mm
Trademark
VACEM
Origin
Wenzhou, China
Model NO.
JCZ6
Power-Frequency Withstand Voltage
95kv
Clearance Between Open Contacts
0.1mm-3.1mm
Mechanical Life
100,000times
Electrical Life
50,000times
Over Travel
Min:2mm
Trademark
VACEM
Origin
Wenzhou, China
1.General description  
    VACZ6 series AC vacuum contactor is suitable for power system of AC tri-phase 50Hz,rated current 630 A and below,rated voltage 36kv,for remotely making and breaking circuit,frequently starting and controlling AC motor.It also could be combined with fuse and protector to replace vacuum circuit breaker.

    The contactor complies with GB/T 14808,IEC 60470 and JB/T 7122 standard,the main performance indicators have reached the international level.

2. Normal using conditions
a. Environment temperature : -5ºC~+40ºC, and average value is no more than +35ºC within 24 hour.
b. Altitude: no more than 1000m.
c. Atmospheric conditions: monthly highest humidity in the most wet month is no more than 90% and monthly average minimum temperature
shall be 25ºC. Condensation on the products due to temperature changes shall be considered.
d. Impact vibration: The place is without extensive shaking, impact, and vibration.
e. The place is without explosion hazard, enchant gas and sleet.
f. No rain and snow in places
g. Pollution degree: Three grade
h. Installation type: .III
i. Installation condition: Slant angle between installation surface and vertical surface is no more than 15°.
3.Main technical parameter
ItemUnitData
Main circuit rated voltagekV36(40.5)
Main circuit rated currentA630
Rated frequencyHz50
Power frequency withstand voltagekV95
Rated making currentA/100times6000
Rated breaking currentA/50times5000
Maximum breaking currentA/3times6000
Opening timems≤50
Closing timems≤80
Clearance between open contactsmm1.6±1.5
Over travelmm≥2
Mechanical lifetimes100,000
Electrical lifetimes50,000