China Biobase Super Professional HPLC Instrument Gradient System for Sale, Find details about China HPLC Gradient System, High Performance Liquid Chromatography from Biobase Super Professional HPLC Instrument Gradient System for Sale
High Performance Liquid Chromatography-BK1100
Features:
*LCD display
*Front-mounted self-locking switch
*Small size, easy to place, save space
*Standard configuration USB portspace
Model | BK-LCI1100 | BK-LCG1100 | |
High Pressure Constant Flow Pump | Double plunger reciprocating pump | 1 set | 2 sets |
Flow Range | 0.001mL/min-10.000mL/min | ||
Setting Step Size | 0.001mL/min | ||
Flow Accuracy | ≤±0.3% (1.00ml/min, H2O,R.T.,8.5MPa) | ||
Flow stability | RSD≤0.1% (1.00ml/min, H2O,R.T.,8.5MPa) | ||
Maximum Pressure | 42MPa | ||
Display Pressure Error | ≤±3.0% | ||
Pressure Fluctuation | ≤1.0% | ||
Power Dissipation | 80W | ||
UV/VIS Detector | Wavelength Range | 190-700nm | |
Wavelength Repeatability | ±0.1nm | ||
Wavelength Accuracy | ≤±1.0nm | ||
Spectrum Band Width | 8nm | ||
Response Time | 0.0s-4.9s | ||
Linearity Range | 1.8AU (5%) | ||
Baseline Noise | ≤±1×10-5AU | ||
Baseline Drife | ≤2.0×10-4AU/h | ||
minimum Detectable Concentration | 4.0×10-9g/mL(Naphthalene in Methanol Solution) | ||
Detector Cell | Optical Path--10mm, Volume--10μL | ||
Light Source | Deuterium Lamp | ||
Power Dissipation | 100W | ||
Gradient Mixer | / | GM1100 | |
Sampler Injector | 1 | ||
Supersil ODS2 5μm ID4.6×200mm | 1 | ||
Workstation (Without Computer & Printer) | 1 | ||
Valve Mounting Frame | 1 | ||
Kits | Isocratic System Kits | Gradient System Kits | |
Power Supply | AC110/220V±10%, 50/60Hz | ||
Optional Accessory | Column Oven |
Features:
* Adopting mature and reliable mechanical structure, optical structure and circuit structure of core technology
* Stepper motor 64 subdivision control technology to improve accuracy at low flow rates
* Straight-through pressure transmitter
* Scientific air duct design to effectively reduce baseline drift
Technical Parameters:
Model | BK-LCI3100 | BK-LCGH3100 | BK-LCQL3100 | |||
High Pressure Constant Flow Pump | Quantity | 1 Set | 2 Set | 1 Set | ||
Flow Rate Range | 0.001mL/min-10.000mL/min | |||||
Flow Accuracy | ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa) | |||||
Flow Precision | RSD≤0.075% (1.00ml/min, H2O,R.T.,8.5MPa) | |||||
Maximum Pressure | 45MPa | |||||
Pressure accuracy | ≤±3.0% | |||||
Pressure pulsation | ≤0.1MPa | |||||
UV/VIS Detector | Wavelength Range | 190-700nm | ||||
Wavelength Repeatability | ≤0.1nm | |||||
Wavelength Accuracy | ≤±1.0nm | |||||
Band Width | 8nm | |||||
Response Time | 0.0s-5s | |||||
Baseline Noise | ≤±0.5×10-5AU | |||||
Drift | ≤1.0×10-4AU/h | |||||
Path length | 10 mm(analytical cell) | |||||
Light Source | Deuterium Lamp | |||||
Low-Pressure Gradient Unit | Integrated vacuum degasser | / | / | 4 channel | ||
Composition Rang | 0-100% | |||||
Composition Precision | ≤0.2% RSD | |||||
Composition Accuracy | ≤±2.0% | |||||
Data-processing Workstation | Internal and external standard calculation methods Automatically displays, prints, exports and starts other programs after the completion of a measurement. | |||||
3100 System Kits | 1 Set | |||||
Power Supply | AC110/220V±10%, 50/60Hz | |||||
Optional Accessory | Column Oven, Autosampler, Degasser, Diode Array Detector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector | |||||
Package Size(W*D*H) | 600*440*380mm*4 | |||||
Gross Weight | 68kg |
High Performance Liquid Chromatography- BK5100
Features:
*Highly integrated ARM microcontroller SPI, I2C technology
* Accurate automatic wavelength positioning and excellent wavelength accuracy
* Plunger floating design, more stable output
* Intelligent sequence analysis and batch processing
* Chromatography workstation software meets 21 CFR Part 11
Technical Parameters:
Model | BK-LCI5100 | BK-LCG5100 | BK-LCQL5100 | |
Pump | Type | Isocratic Pump | Gradient Pump | Quarternary Low Pressure Pump |
Flow Rate Range | 0.001-10.000mL/min, in 0.001mL increments | |||
Flow Accuracy | ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa) | |||
Flow Precision | RSD≤0.06% (1.00ml/min, H2O,R.T.,8.5MPa) | |||
Maximum Pressure | 63MPa | |||
Pressure accuracy | ≤±3.0% | |||
Pressure pulsation | ≤0.1MPa | |||
Composition rang | / | 0-100% | 0-100% | |
Composition precision | / | ≤0.2%RSD | ≤0.3%RSD | |
UV/VIS Detector | Wavelength Range | 190-800nm | ||
Wavelength Repeatability | ≤0.1nm | |||
Wavelength Accuracy | ≤±1.0nm | |||
Band Width | 6nm | |||
Response Time | 0.0s-5s | |||
Baseline Noise | ≤±0.25×10-5AU(empty cell, 254nm, 1.0s) | |||
Drift | ≤0.5×10-4AU/h(empty cell, 254nm, 60min) | |||
Path length | 10 mm(analytical cell) | |||
Light Source | Deuterium Lamp and Tungsten Lamp | |||
Data-processing Workstation | Sequence tables for any set of samples Internal and external standard calculation methods Automatically displays, prints, exports and starts other programs after the completion of a measurement. | |||
5100 System Kits | 1 Set | |||
5100 System Manager | Integrated A/D converters | Integrated A/D converters Integrated vacuum degasser, 4 channel | ||
Power Supply | AC110/220V±10%, 50/60Hz | |||
Optional Accessory | Solvent bottle,Column Oven, Auto-sampler,DAD512 Detector, Refractive Index Detector, Evaporative Light Scattering Detector, Fluorescence Detector, PC | |||
Package Size(W*D*H) | 700*570*310mm; 700*570*350mm; 710*583*500mm; 730*450*440mm; 600*440*380mm; 770*450*700mm; | |||
Gross Weight | 156kg |