Hospital Medical Anesthesia Equipment, Anestesia Machine for Anesthesiology Department

China Hospital Medical Anesthesia Equipment, Anestesia Machine for Anesthesiology Department, Find details about China Hospital Medical Anesthesia Equipment, Anestesia from Hospital Medical Anesthesia Equipment, Anestesia Machine for Anesthesiology Department

Model NO.
MCA-850
Working Mode
Closed; Semi-Closed; Semi-Open
5 Tubes Flowmeters
O2:0.1~10L/Min, N2o:0.1~10L/Min; Air: 0.1~10L / Mi
Safety Valve
<12.5 Kpa
Respiratory Rate
1~99bpm
Modes of Ventilation
A/C, Ippv, Sippv, Imv, Simv, Pcv, Vcv, Peep, Manua
Rapid Oxygen Flush
25~75 L/Min
Trademark
Mecan
Transport Package
Standard Package for Export
Origin
China (Mainland)
Model NO.
MCA-850
Working Mode
Closed; Semi-Closed; Semi-Open
5 Tubes Flowmeters
O2:0.1~10L/Min, N2o:0.1~10L/Min; Air: 0.1~10L / Mi
Safety Valve
<12.5 Kpa
Respiratory Rate
1~99bpm
Modes of Ventilation
A/C, Ippv, Sippv, Imv, Simv, Pcv, Vcv, Peep, Manua
Rapid Oxygen Flush
25~75 L/Min
Trademark
Mecan
Transport Package
Standard Package for Export
Origin
China (Mainland)
Hospital Medical Anesthesia Equipment, Anestesia Machine for Anesthesiology Department

Hospital Medical Anesthesia Equipment, Anestesia Machine For

Anesthesiology Department

 

Model:MCA-850Hospital Medical Anesthesia Equipment, Anestesia Machine for Anesthesiology Department

What is the detail of our hospital anesthesia equipment?


Prospective service and support

MCA-850 Anesthesia Machine is equipped with an accurate dedicated anaesthetic vaporizer and a safety device for preventing cyanosis and necessary alarm system. During the anesthesia, the patient's respiratory functions can be managed by using a microcomputer controlled pneumatic electrically controlled synchronizing anesthesia respirator. Each connection part of the whole machine is a standard interface. A highly efficient and large volume soda lime absorber can minimize the re-inhalation of carbon dioxide by the patient.

 

Power On Self Test

The automatic conversion for standby power while AC power outage,  keep working  not less than 1 hour.

 

Component Details

Na Lime Tank: Equipped with international advanced one-piece soda lime cans,it can be fast replaced with  hands  and  withstand temperatures up to 134ºC

Circuit: Metal integrated breathing circuit, Perfect function of gas sealing under high temperature disinfection, and easy to cleaning and disinfected.Hospital Medical Anesthesia Equipment, Anestesia Machine for Anesthesiology Department

Flowmeter: 5-Tubes flowmeter;

1. Assure that O2 output not lower than 20%

 

2. NO2 automatically off while O2deficiency

Display & Operating  Interface:

10.4'' LCD Display Screen, can feedback patient data

Shuttle button: More accurateHospital Medical Anesthesia Equipment, Anestesia Machine for Anesthesiology Department

Vaporizers:  En flurane/ Iso flurane/ Sevo flurane(Option: Halothane)  
Setting Range:  0.5~5%
Hospital Medical Anesthesia Equipment, Anestesia Machine for Anesthesiology Department
 

What is the specification of our anesthesia machine?

 

Physical specifications 
Screen: 10.4 ''  LCD  Display Screen
SuitableAdult & Child
 Mode:pneumatically powered and electrically controlled system
Working Mode:Closed; Semi-Closed; Semi-Open
CircuitBreathing circuit integrated standards
Flowmeters:5 Tubes Flowmeters:  O2:0.1~10L/Min,  N2O:0.1~10L/Min; Air: 0.1~10L / Min
Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Drawer unitTWO drawers  totally extractable
Technical Specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ;   NO2: 0.32 MPa to 0.6 MPa.
safety valve <12.5  kPa
Respiratory Rate1~99bpm
oxygen concentration in the mixed gas N2O/O2 > 21%
Oxygen Flush: 25~75 L/min
modes of ventilationA/C, IPPV, SIPPV, IMV, SIMV, PCV, VCV, PEEP, MANUAL, SIGH
PEEP:0 ~ 2.0 kPa
Inspiratory trigger pressure-1.0kPa ~ 2.0 kPa
IMV frequency:..
I/E Ratio8:1 ~ 1:10, Has the inverse ratio ventilation
Tidal Volume0 ~ 1500 ML
Inspiratory Plateau0~1s
O2 Concentration21%~100%
Sighone deep breath per 70 ~ 120 controlled respirations, the inspiration time is 1.5 times of the setting point
Maximum safety pressure:≤ 12.5 kPa
Pressure limit range:0 ~ 6.0  kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicatingLower: 0.2kPa~5.0kPa;   Upper: 0.3~6.0  kPa
±0.2 kPa
Tidal volume alarm: Audible and visual and with yellow and red color indicatingupper alarm: 50 to 2000ml, lower alarm: 0~1800ml
Oxygen concentration alarm: Audible and visual and with yellow and red color indicatingupper alarm: 21% ~100%;  lower alarm:10%~80%
Power Supply AlarmAc/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature10 ~ 40
Relative humidityno higher than 80 %
Atmospheric pressure:860 hPa ~ 1060 hPa
Power requirement: 100-120 Vac, 50/60 Hz;  
Attention: the AC power supply used for the anesthesia machine must be well   grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. 
Storage
Ambient temperature: -15 ~ +50
Relative humidity: no higher than 95 %
Atmospheric pressure: 86 kPa ~ 106 kPa.
 It should be stored in a room without corrosive gas and well ventilated
Package
packaging boxcomply with the requirement of GB/T 15464
 Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
 Moisture protection and rain protection to ensure that product is protected from natural damage. 
Safty & Alarm
Oxygen AlarmIt alarms when the oxygen  supply from pipe or cylinders lower than 0.2MPa
Ventilation Volume AlarmLower: 0~12L/Min;   Up: 18L/ Min
Power AlarmIt Alrmas while AC and DC supply failure ; Keep alraming  time: >120s
Air Tract Pressure AlarmLower: 0.2kPa ~5.0 kPa;  Up: 0.3kPa ~ 6.0kPa