Economic Ambulance Medical Ventilator AJ-2205

Economic Ambulance Medical Ventilator Aj-2205

Specification:

Display: Colored 5.7" LCD, touch screen setting, big font display, free changeable angles of views   

Various ventilation modes: SIPPV,SIMV,PCV,SPONT,MANUAL,CPAP

Ventilation parameters: PEEP,SIGH,IRV,Inspiratory platform

Tidal Volume: 50-1500 mL

Rate: 1~99bpm

SIMVrate: 2~20bpm

I:E: 4:1~1:8  

Trigger sensitivity: -1.0~1.0kPa    

PEEP: 0~25cmH2O  

Pressure control: 3~50cmH2O  

SIGH: 1.5 times the inspiratory time (60 ~ 120 times adjustable)      

Inspiratory platform: 0~50%   

Oxygen concentration: 48%~100%   

Pressure limit: 5~60cmH2O  

Parameters for ventilation monitoring: tidal volume, ventilation volume, IPPV rate, total respiratory rate, peak pressure of airway, pressure - time waveform, flow rate - time waveform, inspiratory trigger pressure, Inspiratory platform, Oxygen concentration, battery capacity
Safety alarm system   
 

Airway pressure alarm: upper limit setting range   0.3~6.0 kPa
                                      lower limit setting range    0.2~5.0 kPa

Per-minute ventilation volume alarm: upper limit setting range 3.0~30L/min  
                                                           lower limit setting range  1.0~10L/min

Vt alarm: upper limit setting range 10~2000ml    
                lower limit setting range  0~1800 ml   
  

Sustained high-pressure alarm: it will give alarm when stress have consistently been higher                                                       than 2.5 kPa     
                                              

Suffocation alarm: it will give sound and light alarm if there is no tidal volume input                                             for15seconds     

Power failure alarm:     
 

                                  Power: AC 220V±10%     50Hz±1Hz  UPS, Storage battery  
  

                                  Battery under-voltage alarm

                                  Power loss alarm  

Intubation off alarm
    

Heated humidifier      


CE & ISO:

Economic Ambulance Medical Ventilator Aj-2205      Economic Ambulance Medical Ventilator Aj-2205

Clients Feedback:

Economic Ambulance Medical Ventilator Aj-2205

Packagings:

Economic Ambulance Medical Ventilator Aj-2205




Arab Health Exhibition Show:

Economic Ambulance Medical Ventilator Aj-2205

South Africa Exhibition Show:

Economic Ambulance Medical Ventilator Aj-2205

Kenya Exhibition Show:

Economic Ambulance Medical Ventilator Aj-2205


Contact Us:

Economic Ambulance Medical Ventilator Aj-2205