Superstar Dm6aveterinary Anesthesia System

China Superstar Dm6aveterinary Anesthesia System, Find details about China Veteriany, Anesthesia System from Superstar Dm6aveterinary Anesthesia System

Model NO.
DM6A
HS Code
9019200090
Model NO.
DM6A
HS Code
9019200090

Superstar Dm6aveterinary Anesthesia SystemSuperstar Dm6aveterinary Anesthesia SystemSuperstar Dm6aveterinary Anesthesia SystemSuperstar Dm6aveterinary Anesthesia SystemSuperstar Dm6aveterinary Anesthesia System

Main technical specification of DM6A

Gas supply

  1. Gas supply     O2(For medical use)
                                         N2O(For medical use)
  1. Input pressure range          280 kPa~600 kPa
  2. Output pressure of regulator
(gas cylinder supply)                   less than 440 kPa
  1. Safety valve      750kPa
  1. Negative pressure air source            ≥75 L/min

 Flow rate 

  1.  Adjust range of flow meter
O2           0 L/min~10 L/min
N2O             0 L/min~10 L/min
  1.  precision(20ºC 101.3kPa,supply pressure 440 kPa)
The precision from 10 % of full scale to full scale is ±10 % of indicated value
The precision lower than 10 % of full scale is class 4.
  1. Linkage control of O2  and N2O flow rate
Adjust O2 concentration to no less than 25 % according to proportion.
  1. Flow rate of oxygen flush valve       25 L/min~ 75 L/min  

Power supply

  1. Voltage             100-240 V ~
  2. Frequency             50/60 HZ
  3. Input power             80VA
  1. Fuse
--Main power         T2AH 250V
--Internal power             T4AH 250V
 

Ventilation mode

--IPPV
--A/C
--SIMV
--PCV

Ventilation parameters

Specification

  1. Frequency
--Adjusting range                1 bpm ~ 100 bpm
(Under SIMV:1 bpm~ 40 bpm
All mode except SIMV:
VTH   4 bpm~40 bpm
VTL   20bpm~100 bpm )
--Allowable error          ± 15 %
  1. Inhalation time(I:E)(Tinsp)  
--Adjusting range           VTH   4:1(1:0.25) ~ 1:8
                                           VTL   2:1(1:0.5) ~ 1:8
Tinsp   0.2s ~ 12.0s
--Allowable error             ± 15 % or ± 0.1 s,
whichever is the greater
  1. Tidal volume(VT)
--Adjusting range              0,20 mL ~ 1500 mL
And:
VTH           250 mL ~ 1500 mL   
VTL               0,20 mL ~ 300 mL
  1. Minute ventilation(MV)  
--Max MV
VTH           ≥18 L/min
VTL           10 L/min
  1. PEEP
--Adjusting range               0 kPa ~ 3kPa
-- Allowable error                        ±15 % or ±(0.3 kPa+10 % setting valve)whichever is the greater
  1. Pressure trigger(PTr)
--Adjusting range                 - 2.0 kPa ~ 0kPa(Under PEEP) 
--Allowable error                         ±(0.1 kPa+10 %setting valve)
  1. Flow trigger(FTr)
--Adjusting range  OFF, 0.5 L/min ~ 30 L/min
--Allowable error                  
                                            >3L/min:   ±20%
3L/min:  ±0.6 L/min
  1. Pressure control(Pc)
--Adjusting range             0.5kPa ~ 6.0 kPa
-- Allowable error                         ± 15 % or ±(0.3 kPa+10 % setting valve)whichever is the greater
  1. Holding time(Inhalation platform)(TIP)
--Adjusting range 0 ~ 6s
(0% ~ 50% of inhalation time)
--Allowable error                    ± 15 % or± 0.1 s,whichever is the greater
  1. Sigh
     --Adjusting range                           0, 1/100 ~ 5/100
                                              (Sigh tidal volume is 1.5 to 2 times higher than setting valve of tidal volume)
  1. Apnea ventilation
--Adjusting range                            OFF,5 s ~ 60 s
  1. Max set working pressure(pressure limit range)
--Adjusting range 3kPa ~ 10kPa
--Allowable error  ± 15 % or ±(0.2 kPa+10 % setting valve)whichever is the greater
Max pressure   ≤12.5 kPa
explanation:
1) set pressure limit value to produce maximum working pressure( the upper limit of high airway pressure alarm).
2) do not use negative pressure at exhalation.
3) maximum limit pressure is pressure of the safety valve.

Driven gas

  1. Gas supply              O2(For medical use)
  2. Input pressure range                  280 kPa ~ 600 kPa

Fresh gas compensation

  1. Compensation range              0 ~  15 L/min
  2. gas composition                               O2, N2O and anaesthetic
 

Ventilation parameter Monitoring 

  1. The following are monitoring parameters under the environment of body temperature and pressure-saturated.  
  2. Minimum exhalation volume maybe monitored is 50 mL/min.
  3. Fig. display:
ParameterRangeResolving powerAccuracy
Frequency(Freq)1 bpm ~ 100 bpm1 bpm ±15 %
Tidal volume(VT)0~ 2000 mL10 mL>100 mL:±20%
100 mL:±0.02 L
Minute ventilation(MV)  0~100L/min0.1 L/min>1L/min:±20%
1L/min:±0.5 L/min
(Ppeak)0~100 cmH2O1 cmH2O±(4%full scale+4%actual reading)
O2 concentration15 % ~ 100 %0.1 %±[ 2.5 %(v/v)+2.5 %(concentration level)]
Compliance1~1000mL/ cmH2O1mL/ cmH2O 
  1. Waveform display:

--Time-airway pressure(under all modes)
--Time-flow(under all modes)
--pressure volume loop(under all modes)
--Time-volume(under all modes)
--Time-CO2(under all modes)
Remarks:The machine cannot record all the adjusting and monitoring values.