5A, 1A Clamp on Current Sensor 400- 1000A

China 5A, 1A Clamp on Current Sensor 400-1000A, Find details about China Isolation Transformer, TCP202 Current Probe from 5A, 1A Clamp on Current Sensor 400-1000A

Model NO.
GWTA
Insulating Medium
Insulating Paper
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Capacitive Type
Design Advantage
Clamp on Current Transformer
Accuracy
1%
Primary Current
0.1-1000A
Useable Frequency
10Hz to 100kHz
Window Size
Check Specification Below
Maximum Voltage
600VAC
Output Signal
Ma/a or Mv/a
Operating Temp
-10c to +50c
Maximum Non-Destructive Current
2000A
Export Markets
Global
Trademark
grewin
Transport Package
Export Standard Cartons with Strong Pallets
Specification
CE
Origin
China
HS Code
850450000
Model NO.
GWTA
Insulating Medium
Insulating Paper
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Capacitive Type
Design Advantage
Clamp on Current Transformer
Accuracy
1%
Primary Current
0.1-1000A
Useable Frequency
10Hz to 100kHz
Window Size
Check Specification Below
Maximum Voltage
600VAC
Output Signal
Ma/a or Mv/a
Operating Temp
-10c to +50c
Maximum Non-Destructive Current
2000A
Export Markets
Global
Trademark
grewin
Transport Package
Export Standard Cartons with Strong Pallets
Specification
CE
Origin
China
HS Code
850450000
5A, 1A Clamp on Current Sensor 400-1000A

100A 200A 50A Low Current Clamp Meter
Current probe(specifications)
Rated Primary current0.1A-1000A
Output signalmA/A or mV/A
 Maximum Non-Destructive Current2000A
Basic Accuracy1%
SafetyCAT III 600V
Dielectric Resistance1000MOhms @ 500 Vdc
Case MaterialPolypropylene resinUL flame retardant rating 94-V0
Voltage rank600Vac(isolated condition), 30Vac(bareness condition)
Maximum voltage600Vac
Useable frequency10Hz - 100kHz
Maximum Cable Diameter2.05 inches (52 mm)
 Dimensions 4.37x8.5 x1.77 in. (111x216x45 mm)
Operating Temperature-10ºC to +50ºC
StandardIEC 60044-1
AccessoriesSupplied with feet for base mounting if required
CertificationRoHS compliant CE&ETL approved

 
Current probe(features)
Good appearance
Low cost
5 standard sizes
Clamp-on core design,safer,easier installation, portable
Both Silicon Steel & Nickel Alloy cores available
Current or three specs voltage output signal 
Current probe(applications)
Current, power energy,monitoring devices
Power Factor Correction devices
Oscilloscope and harmonic waves analyzer
Part numberInput currentRated OutputFrequency
(Hz)
Secondary
Burden
Resistance
Accuracy
Class
GWCTC15350.5-1000A1mA/A40-1KHZ≤10 Ohms1%
400-1000A5A,1A50/60HZ≤2VA1%
0.1-10A100mV/A10-1000K≥100KOhms3%±10mV
0.1-100A10mV/A2%±5mV
1-1000A1mV/A1%±1mV
0.5-1000A4-20mA50/60HZ≤100 Ohms1%
 
100A 200A 50A Low Current Clamp Meter
GWQCT03 Clamp sensor Specification 

Technical datas:
Rated primary current:Max 500A  AC
Output voltage:333 mV AC
Amplitude accuracy:±0.5% rdg.±0.1%f.s. (f.s.:500A, 45Hz - 66Hz, Primary conductor in the enter)
Phase accuracy±1°(10~100%I1n)(45 Hz - 5 kHz)
The amplitude frequency characteristic±1% (45 Hz - 5 kHz) ( Deviation  Accuracy)
Conductor impact±0.5%(off-center)
The influence of external electromagnetic fields≤0.1 A(in AC 400A /M electromagnetic fields)
Maximum input current 550A  AC continuous (45-66 HZ  Ambient  temperature 50°C)
Temperature coefficient0.02 %reading data /°C
Dielectric strength5312 V ACrms /continuous 15(circuits- core)
Maximum rated voltage 600V ACrms
Woring temperature& humidity0 to 50°C (32 - 122°F), 80%RH (No condensate)
Woring temperature& humidity-10 to 60°C (14 - 140°F), 80%RH (No condensate)
Indoor  using and up to 2000m above sea  level
Standardssacurity:EN61010 - 2 -032:2002 , CAT III,contamination II
EMC:EN61326:1997+A1:1998+A2:2001+A3:2003(Class A)  
Measure conductor diameter≤Φ46mm 
Cable length2m
SizeAbout 78W x 160H x 40D mm(excluding protruding parts)
weightAbout 380g
AccessoryInstrution manul  one piece 
  f.s. :Maximum display datas or scale length
 rdg:Reading value (the value of the current is measured and displayed in the measurement of the product)


We can produce following similar clamp on current transformer:
100A 200A 50A Low Current Clamp Meter
100A 200A 50A Low Current Clamp Meter

100A 200A 50A Low Current Clamp Meter
1-200A Clamp on current transformer(specifications)
Rated Primary current1-200A
Turn ratio1:1000 1:2000 1:2500
Output0.333V 1.5V
Accuracy0.1, 0.2 ,1.0 Class
Second burden(Ohms)<=5, <=50 ,>=100k
Dielectric Resistance1000MOhms @ 500 Vdc
Case MaterialPolypropylene resinUL flame retardant rating 94-V0
Voltage rank600Vac(isolated condition), 30Vac(bareness condition)
High Potential2500Volts/min
Frequency Range:50/60Hz
Operating Temperature-25ºC to +70ºC
StandardIEC 60044-1
AccessoriesSupplied with feet for base mounting if required
CertificationRoHS compliant CE&ETL approved
 
Clamp on current transformer(features)
Low cost
5 standard sizes
 Clamp-on core design,safer,easier installation, portable
Both Silicon Steel & Nickel Alloy cores available
Clamp on current transformer(applications)
Silicon Steel cores provide moderate accuracy and lower cost for appropriate current measurement
Nickel Alloy cores are suitable for applications that require the highest accuracy with minimal phase angle error. Applications would include electric power quality monitoring devices

Contact Information:                                                     

Alice

Tianjin Grewin Technology Co.,Ltd.

Tel: 86-22-84943756

 Website:

http://transformer.en.made-in-china.com