China Medical Oxygen Generating System Medical Oxygen Refilling System Automatic Medical Oxygen Manifold System, Find details about China Medical Oxygen Manifold System, Medical Oxygen Supply System from Medical Oxygen Generating System Medical Oxygen Refilling System Automatic Medical Oxygen Manifold System
1 | Product gas: | Oxygen (O2) |
2 | Gas production capacity: | 50Nm3/h |
3 | Oxygen purity: | 93% |
4 | Oxygen recovery rate: | ≥40% |
5 | Oxygen dew point: | ≤-45ºC |
6 | Operation mode: | Automatic unattended control |
7 | Detection method of oxygen content: | On line detection |
8 | The device has capacity expansion capacity: | 10% design margin |
9 | Flexibility of system operation: | Adjustable within the rated range |
10 | Valves: | Screw type |
12 | Design pressure: | 0.8MPa |
13 | System operating pressure: | ≤ 5bar (adjustable according to customer's site requirements) |
14 | Filling pressure: | 200bar |
15 | System pressure loss: | ≤ 5% (pressure loss at inlet and outlet) |
16 | System design service life: | 10-15 years |
19 | Explosion proof requirements for system design: | Non explosion proof design |
20 | The degree of automation of system design is as follows | Automatic unattended |
name | Voltage | power |
screw compressor | 3Ph,220V,60HZ | 90KW |
Freeze dryer | 3Ph,220V,60HZ | 3.5KW |
oxygenerator | 1Ph,220V,60HZ | 0.2KW |
Oxygen booster | 3Ph,220V,60HZ | 18.5KW |
total | 113.2KW | |
It takes two tons of water to circulate |
production | Oxygen generator: according to jb6427 / 92 standard Pressure vessel: according to GB 150-1998 standard Welding: according to JB / t4709-92 standard Wire arrangement and installation: Standard gb5226-96 Iso9001:2016 certification Iso13485:2016 certification CE EU certification |
inspect | Oxygen content detection: range: 21% ~ 98% Flow test: flowmeter Acceptance standard: according to the contract and the buyer's requirements Before acceptance, it can be installed and debugged on site. |