Applications
Rammers are designed to compact loose soils and gravel to prevent settling and to provide a firm, solid base for the placement of footings, concrete slabs, foundations, and other structures
MODEL | CJ100 |
Weight kg(lb) | 1000(39)×500(20)×590(23) |
Drive motor | Air-cooled Single-cylinder 4 stroke gasoline engine |
Engine | Honda GX100 3HP |
Jumping stroke mm(in) | 65(2.6) |
Impact frequency ( /min) | 600 |
Walk speed (m/min) | 17 |
Leap Height (mm) | 65 |
Impact force (KN) | 15.0 |
Plate size mm(in) | 340(12)×285(11) |
Tank capacity (L) | 2.2 |
Ramming System oil grade Lubrication | SAE 10W-30 |
Ramming System ml(oz.) Capacity | 890 |
Maintenance schedule
| Daily before starting | After first 5 hours | Every week or 25 hours | Every month or 100 hours | Every 3 months or 300 hours | Every year |
Check fuel level | √ | | | | | |
Check engine oil level | √ | | | | | |
Inspect air filter, replace as needed | √ | | | | | |
Check oil level in sightglass | √ | | | | | |
Check fuel line and fitting for cracks or leaks | √ | | | | | |
Tighten ramming shoe hardware | | √ | √ | | | |
Check and tighten external hardware | | √ | √ | | | |
Clean engine cooling fins | | | √ | | | |
Clean and check spark plug gap | | | √ | | | |
Change engine oil | | | | √ | | |
Replae spark plug | | | | √ | | |
Clean recoil starter | | | | | √ | |
Change rammming system oil | | | | | √ | |
Inspect crane lifting cable for wearm, damage, or abuse | | | | | √ | |
Inspect fuel filter | | | | | | √ |