China Generator Power Frequency High Voltage Resonant Test Equipment, Find details about China Testing Equipment, High Voltage Tester from Generator Power Frequency High Voltage Resonant Test Equipment
Rated output voltage | Rated output voltage: 0~40kV |
Resonant voltage waveform | sine wave, waveform distortion rate <1.0% |
Maximum tested product current | 1.75A 14A |
Maximum test capacity | 560kVA |
Output frequency | 30~300Hz |
Working time | Continuous working time is 60min under full power output |
Quality factor | 30~90 |
Input working power | Three-phase 380V±5%, 50Hz |
Ambient temperature | -15ºC~+40ºC |
Relative humidity | <90RH%, no condensation |
Altitude | <5000m |
Noise | ≤50dB |