on-Grid Inverter 5000W Solar Inverter for Home Solar System

China on-Grid Inverter 5000W Solar Inverter for Home Solar System, Find details about China Inverter 5000W, on-Grid Inverter from on-Grid Inverter 5000W Solar Inverter for Home Solar System

Model NO.
LITTO/OEM
Types
DC/AC Inverters
Output Type
Triple, 3pH+N+PE
Input Voltage
1000V DC
Output Frequency
50/60Hz
Output Current
30A
Efficiency
98-99%
Operating Temperature Range
-25~60
Short Circuit Production
Yes
Trademark
SUNTREE/LITTO/OEM
Transport Package
Standard
Origin
Shenzhen
HS Code
8536620000
Model NO.
LITTO/OEM
Types
DC/AC Inverters
Output Type
Triple, 3pH+N+PE
Input Voltage
1000V DC
Output Frequency
50/60Hz
Output Current
30A
Efficiency
98-99%
Operating Temperature Range
-25~60
Short Circuit Production
Yes
Trademark
SUNTREE/LITTO/OEM
Transport Package
Standard
Origin
Shenzhen
HS Code
8536620000

on-grid inverter 5000w solar inverter for home solar system

Leading - edge 

  • Double MPPT Tracker, MPPT tracking accuracy more than 99.8%
  • Max. Efficiency 97.8%, European Efficiency 97.2%
  • Internal DC Switch for added safety protection
  • Power factor continuously adjustable
  • Flexible communication connection, support USB, WiFi, Ethernet
  • Support Online Update from USB or Ethernet
  • 5 years standard warranty
  • Comply with European, Asia-Pacific safety regulations
  • Transformerless design and high power density, offer lighter and more convenient installation
  •   
    Highperformance string inverters
        Form 3.0kW to 5.0kW
        Wide PV input voltage range
        Rapid MPPT tracking technology
        Two MPPT trackers
        Superior PV energy harvest
        Transformerless design with higher operation efficiency
        Excellent thermal performance
        High overload capability under most ambient conditions
    Full data display and communications
        LCD display energy data
        Bright LED indicators imply system status at a glance
        PC software for remote monitoring and system troubleshooting 
        Interated RS232 and RS485 serial communications
    Cost advantages
        Transformerless design cutting down the cost
        Light weight and small dimension,reducing shipping cost 
        IP65 protection degree, suitable for outdoor installation,reducing construction cost
        Low maintenance expense
    Easy and affordable to install
        Light weight and compact size
        Includes a lightweight portable bracket simplifying installaton 
        Firm IP65 inverter enclosure allows outdoor application


  •  
 

Technical specitications

 

DATA SHEET

LS 3000H

LS 4000H

LS 5000H

INPUT DATA (DC)

Max. recommended PV power

3150W

4200W

5260W

Max. PV power of per MPPT

3150W

4200W

5260W

Max. DC voltage

500V

500V

500V

Start voltage

100V

100V

100V

PV voltage range

70-500V

70-500V

70-500V

MPP work voltage range / nominal voltage

100-500V/360V

100-500V/360V

100-500V/360V

Full load dc voltage range

150-450V

200-450V

250-450V

Max. input current

23.0A

23.0A

23.0A

Max. input current per string
of tracker A/tracker B

23.0A

23.0A

23.0A

Number of independent MPP
trackers/strings per MPP tracker

1/2

1/2

1/2

OUTPUT (AC)

Rated AC output power

3000W

4000W

4960W

Max. AC apparent power

3000VA

4000VA

5000VA

Max. output current

15.0A

20.0A

25.0A

AC nominal voltage; range

220V/230V/240V 180-280Vac

220V/230V/240V 180-280Vac

220V/230V/240V 180-280Vac

AC grid frequency; range

50Hz, 60Hz; ± 5Hz

50Hz, 60Hz; ± 5Hz

50Hz, 60Hz; ± 5Hz

Power factor

0.90 capacitive..0.90
inductive

0.90 capacitive-.0.90
inductive

0.90 capacitive..0.90
inductive

THDI

less than3%
(at nominal output power)

less than3%
(at nominal output power)

less than3%
(at nominal output power)

AC grid connection type

Single phase

Single phase

Single phase

efficiency

Max. efficiency

97.5%

97.5%

97.6%

Euro-eta

96.6%

96.6%

96.7%

MPPT efficiency

99.9%

99.9%

99.9%

Protection DEVICES

DC reverse polarity protection

yes

yes

yes

DC switch for each MPPT

opt

opt

opt

Output over current protection

yes

yes

yes

Output overvoltage protection-varistor

yes

yes

yes

Ground fault monitoring

yes

yes

yes

Grid monitoring

yes

yes

yes

Integrated all-pole sensitive
Leakage current monitoring unit

yes

yes

yes

GENERAL DATA

Dimensions (W/H/D)

355*395*170mm

355*395*170mm

355*395*170mm

Weight

16.5KG

17KG

17KG

Operating temperature range

-25°C to 60°C

-25°C to 60°C

-25°C to 60°C

Noise emission(typical)

25dB(A)

25dB(A)

25dB(A)

Altitude

2000m without derating

2000m without derating

2000m without derating

Self-Consumption(night)

less than 0.5W

less than 0.5W

less than 0.5W

Topology

Transformerless

Transformerless

Transformerless

Cooling concept

Natural

Natural

Natural

Environmental Protection Rating

IP65

IP65

IP65

Relative Humidity

100%

100%

100%

FEATURES

DC connection

H4/MC4

H4/MC4

H4/MC4

AC connection

Connector

Connector

Connector

Display

LCD. LED

LCD. LED

LCD. LED

Interfaces:USB/Wi-Fi/GPRS/RS485

yes/yes/opt/opt

yes/yes/opt/opt

yes/yes/opt/opt

Warranty: 5 years/ 10 years

yes/opt

yes/opt

yes/opt

CERTIFICATE AND APPROVALS

CE, VDE 0126-1-1, IEC 62109, G83-2, G59-3, AS4777, AS/NZS 3100, VDE-AR-N4105, EN50438, EN62116, CQC, MEA, PEA, IEC61683


Suntree series string solar three phase inverter 
 Compact size and high power density
    High speed MPPT for real time power tracking and improved energy harvesting
    Transformerless operation for highest efficiency 98.2%
    High overload capability under most ambient conditions
    Certified grid connected operation according to the international standards
    True three phase sine wave output
    Integrated RS485/RS232 serial communications
    Multi-language friendly LCD display
    Easy maintenance cooling fans
MODEL(LT)5000HD6000HD8000HD10000HD12000HD15000HD17000HD20000HD30000HD
Max. DC Input Power(W)550066009000115001330017000190002200033000
Max DC Voltage(Vdc)9001000
MPPT Operating Range(Vdc)250~720250~800
Number of  Parallel Inputs24610
Number of  MPPT Trackers2
Max.Input Power per MPPT35004000500060007000850095001100016500
Max. Input Current(A)2*102*122*162*222*242*302*322*352*41
Nominal Output Power(W)500060008000100001200015000170002000030000
Max. Output Power(W)500060008000100001200015000170002000030000
Nominal Output Current(A)7.38.711.614.517.421.724.62943.5
Max. Output Current(A)7.99.512.716.219.424.327.532.348
Nominal AC Output Voltage(Vac)400
AC Output voltage range (Vac)*360~440
AC Grid frequency range (Hz)*50/60±5
Power Factor (cosφ)0.9(leading)~0.9(lagging)
THDI<3%(at nominal power output)
Max.efficiency97.6%97.8%98.1%98.1%98.1%98.1%98.1%98.2%98.1%
Euro.efficiency96.7%96.9%97.3%97.5%97.6%97.5%97.6%97.6%97.5%
MPPT. efficiency99.6%99.6%99.6%99.6%99.6%99.6%99.6%99.6%99.6%
Operating Temperature(ºC)-25~+60
Noise typical[dB(A)]<25<50<65
Operating Consumption(W)0
Electrical IsolationTransformerless
Cooling ConceptNatural CoolingFan Cooling(IP54)
Protect LevelIP65
  • LCD Screen: Display the operating data and situations, warning/error codes and information.
  • The model of inverter (for example, 10000TL)
  • ALARM LED: Indicates the alarm of inverter.
  • POWER LED: Indicates the inverter is running normally.
  • Fault LED: Indicates the fault of inverter.
  • Function Key: Used to set different parameter and display language for the inverter.   
  • Description of inverter
CommunicationRS485/RS232(WIFI Optional)
Dimension (W×D×H)(mm)470*165*560470*165*585470*165*670580*235*800
Weight (Kg)32355065

Opening the package
After opening the package, please check the contents of the box. It should contain the following accessories: 
 
ItemNameQuantity
1.Solar inverter1pcs
2.Mounting frame1pcs
3.Mounting screws and blocks9pcs  
4.Safety-lock screws4pcs
5.Socket head wrench1pcs
6.DC socket assembly1set
7.Special RS-232 cable1pcs
8.Instruction manual1pcs
9.Monitor software(CD)1pcs
10.Warranty sheet1pcs


on-Grid Inverter 5000W Solar Inverter for Home Solar System
on-Grid Inverter 5000W Solar Inverter for Home Solar System

 
  • LCD Screen: Display the operating data and situations, warning/error codes and information.
  • The model of inverter (for example,Suntree 10000TL)
  • ALARM LED: Indicates the alarm of inverter.
  • POWER LED: Indicates the inverter is running normally.
  • Fault LED: Indicates the fault of inverter.
  • Function Key: Used to set different parameter and display language for the inverter.   
  • Description of inverter
LED indicators
Information ListGreen LEDYellow LEDRed LED
Wait StateFLASHOFFOFF
Fault RevoverOFFONOFF
Normal StateONOFFOFF
Fault StateOFFOFFON
Permanent StateONOFFOFF

Wait State: Inverter is waiting to Check State until the end of reconnection time. In this state, 
the PV voltage is more than 250V and grid voltage value is between the max and min limit; Otherwise, 
Inverter will go to Fault State or Permanent State.

Fault Revover: Inverter is in the process of circulating in take place mistake or breakdown, 
break down Inverter to re- combine a net after the relief

Normal State: Inverter feeds to grid energy from PV panel as much as possible according MPP trackers. 
Inverter will go to FaultState or PermernentState if any error or fault occurs.

Fault State: Inverter has occurred some recoverable error
Permanent State: Inverter has occurred some unrecoverable error. It will stay in Permenent State. 
You should take some measure according the error code.

 


3.2 Operate the Function Key
To view the operating data of the inverter, you can press the Function Key. 
Of course, the data also will automatically and 
periodically display. 
To 
set different display contrast and display language for the inverter,
 please carefully refert to the following chart.
 

Step 1: Ensure that the AC cable and DC cable is connected correctly, unused DC plugs and AC terminal cover are sealed.
Step 2: Connect the DC and AC switches. The inverter starts up automatically when DC-power from the PV strings is sufficient.
Once the solar inverter starts, it enters one of the following 3 states in turn:
Standby: The PV string can only provide just enough voltage to minimum requirements of the internal controller unit.
Waiting: When the PV string DC voltage is greater than 200V, The inverter enters a "waiting" state and attempts to connect to the grid.
Normal: When PV string DC voltage is greater than 300V, Inverter operates in the normal state.
The Inverter will keep MPPT function and deliver power to AC Grid when it is in normal operation. 
Maybe it will stop under the situation of low input DC-power, 
Don
't worry, it will automatically restart again when DC-power from the PV string is sufficient.



Error or Warning status
Inverter is designed to be user-friendlytherefore, the error or warning status of the Inverter can be easily understood by reading the i
nformation shown on the front panel di
splay. All possible messages are shown in the following table.

 

 DISPLAYCOMMENTS
 System fault
1Auto Test FailedAuto Test does not pass
2No UtilityNo Grid Connect
3PV Over VoltagePV panel Voltage is too high
4Isolation FaultInsulation Problem of PV panel
5GFCI Faultleakage current is too high
6Grid Freq. FaultGrid frequency is out of range
7Grid Volt. FaultGrid voltage is out of range
 Inverter fault
1Consistent FaultConsistent Fault
2Over Temp. FaultInternal temperature abnormal
3Relay FaultOutput relay Fault
4DCI Out RangeOutput Current DC Offset too high
5REEPROM FailEEPROM Fault
6Comm. LostCommunication Fault
7Bus Over VoltageDC Bus over-voltage
8Bus Low VoltageDC Bus under-voltage
9Boost FaultBoost Current or Voltage Fault
10GFCI Device FaultGFCI Device is damaged
11Inv. Curr. OverInverter output current too high
12Fan LockFan Lock
13RTC FailReal Time Clock IC Fault
14SCI Fault Communication Fault
 

Warranty Claim Procedure:

Please report defective devices with a brief error description to the SUNTREE distributors.
 If we agree to a replacement, we generally send an equivalent replacement device according to model 
and age, 
the remainder of the warranty entitlement will be transferred to the replacement device. In this case, 
you do not receive a new certificate since your entitlement is documented at 
SUNTREE
The replacement will be packaged appropriately for transport and shipped out 
within 2 working days. 
The defective device is to be packed in this transport packaging for return transport to
 the distributor.
 If the on-site service of re-installation is necessary,
 the end customers need to negotiate with the distributors in advance.
 All warranty services in warranty period are free of charge.

  
on-Grid Inverter 5000W Solar Inverter for Home Solar System