3000va off-Grid Solar PV Inverter for Energy Storage

China 3000va off-Grid Solar PV Inverter for Energy Storage, Find details about China Power Inverter, off Grid from 3000va off-Grid Solar PV Inverter for Energy Storage

Model NO.
GPDA3000VA-C
DC Rated Input Current
80A
Rated Output Voltage
220VAC
Rated Output Current
1091 a
Rated Output Frequency
50Hz
Rated Capacity
3000va
Max. Power
3000W
Output Efficiency
88%
Output Power Factor
0.8
Weight
≤4kg
Trademark
Goldpower
Transport Package
Carton
Specification
481.6*270*88.1 mm
Origin
Shenzhen
HS Code
8504401990
Model NO.
GPDA3000VA-C
DC Rated Input Current
80A
Rated Output Voltage
220VAC
Rated Output Current
1091 a
Rated Output Frequency
50Hz
Rated Capacity
3000va
Max. Power
3000W
Output Efficiency
88%
Output Power Factor
0.8
Weight
≤4kg
Trademark
Goldpower
Transport Package
Carton
Specification
481.6*270*88.1 mm
Origin
Shenzhen
HS Code
8504401990
GPDA3000VA-I is one model from Goldpower Off-Grid inverter series, with AC bypass input and RS485 communication

Feature:
 1. Flexible and efficient
 2. Easy installation
 3. Safe and reliable

Application:
 
1. Emergency ESS
 2. Residential ESS
 3. Commercial ESS

Specification:
Model   GPDA3000VA-CRemark
Item Parameter 
DC InputDC operating voltage range40~58Vdc 
DC startup 
voltage range
42~56Vdc 
Rated input voltage48Vdc 
Input current80Arated input,rated output.
Startup Max. inrush input150A 
AC outputRated output voltage220Vac 
Rated output current1091Apower factor 0.8
Output stabilized voltage precision±5% 
Rated output frequency50Hz 
Rated capacity3000VA 
Rated output power2400W 
output efficiency88%Under rated operating conditions
output power factor0.8Under rated operating conditions
Dynamic transient recovery time100ms 
Voltage waveformSine wave 
THD<3%
Linear load
Sine wave 
THD<8%
Non-linear load
Over load ability105 ~ 125% sustained no less than 60s, 125 ~ 150% sustained no less than 10s
Output current peak coefficient3:1
Output methodTwo national standard socket, a wiring output, each output of a single pole open control
Inverse conversion bypass conversion time<5ms 
Power supply priority modeInversion priority 
ProtectionDC input under voltage protection point37~40 Vdcwith half load test
DC input under voltage recovery point40~42 VdcReached to the recovery value,auto recovery.
DC input over voltage protection point58~60 Vdcwith half load test
DC input over voltage recovery point56~58 VdcReached to the recovery value,auto recovery.
Over temp. protectionWhen the main radiator temperature is too high, up to over-temperature protection point, turn off the output, the temperature hysteresis is about 10 ºC.
Anti-reverse protectionWhen the input reverse, the power does not work, and no damage
Short circuit protectionWhen a short circuit is detected, the power is turned off and an alarm signal is issued. It is automatically restarted every 30 seconds. After the fault is removed, it can be restored. Long-term short circuit, the power off lock, re-boot can work properly.
Over current protectionWhen overcurrent is detected, the power is turned off and an alarm signal is issued. When the load returns to the rated value, it can be restored. Long-term overload, the power off lock, re-boot can resume normal work.
Alarm function(sharp alarm)DC input abnormal, overload, short circuit, inverter failure, the wind alarm, while warning lights.
AmbientOperating temp.-5~+40ºC 
Storage inverter temp.-25~+70ºC 
Relative humidity0~95% 
Altitude3000m 
CoolingForced air cooling 
Operating ambientNo conductive explosion of dust, no corrosion and damage to the gas and steam, no severe vibration and shock.
InsulationParameterStandard requirementRemark
Dielectric strengthInput-output:2000Vac/10mA//1minNo flash, no breakdown
Input-earth:500Vdc/10mA//1min
Output-earth:1500Vac/10mA//1mi
Insulation resistanceAt normal atmospheric pressure, the relative humidity of 95%, the test voltage is DC 500V, the power input to the output, input to the ground, the output to the ground insulation resistance of not less than 10MΩ.
EMCConductioncomply to standard YD/T983-1998 A
Radiationcomply to standard YD/T983-1998 A
Immunitycomply to standard YD/T983-1998 A
Noise<55dB(1meter)
The shell protection levelIP20(indoor)
SmellNo smell and other harmful smell to health
MechanicalDimension481.6*270*88.1 mm
 Weight≤4KG
3000va off-Grid Solar PV Inverter for Energy Storage