China Wall Mounted Induction Wc Squant Pan Water Flusher Automatic Toilet Washing Control, Find details about China Automatic Toilet Flusher, Sensor Wc Flush from Wall Mounted Induction Wc Squant Pan Water Flusher Automatic Toilet Washing Control
Product Feature
1) Automatic on/off: Infrared sensor toilet flusher automatically turns on and off (Convenience & Hygiene).
2) Adjustable sensor range by a remote controller.
3) Flush program: Normal Mode flush time 5s; Water saving Mode: usage time less than 1min: 4s/flush while using time more than 1min: 5s/flush
4) Low power indication: This may indicate it is time to replace existing batteries with new ones or there is not enough power going to the unit.
5) Water-saving: Water efficient toilet flusher reduces overall water usage without sacrificing water pressure.
6) Energy-saving: Battery shall last approximately 3000 times/month for one year.
7)Electronic manual push button
Rated Voltage | DC6V |
Coil resistance | 25Ω ±0.5Ω(20ºC) |
Min current | 160mA |
Switch mode | DC pulse(latching type) |
Pulse width | ≥10ms |
Operating pressure | 0.05Mpa-0.8Mpa |
Media temperature | 1ºC--75ºC |
Responding time | Open ≤0.15s close≤2s |
Strength test | Static pressure 1.6MPa | Withstand voltage pressure | 1.2MPa/5min | ||
No-load test | Voltage 3.6V pulse width 30ms | Permissible limiting voltage | V*1.15 | ||
High water pressure start and close | At water pressure 0.8MPa,voltage DC4.5V,pulse width 10ms,the solenoid valve can be started and closed normally | ||||
low water pressure start and close | At water pressure 0.02MPa,voltage DC4.5V,pulse width 10ms,the solenoid valve can be started and closed normally | ||||
Leakage upon high water pressure | 1.2MPa without leakage | ||||
Leakage upon low water pressure | 0.05Mpa leakage≤0.1ml/min | ||||
Electric strength | Among conductive part, mounting hole and nonconductive metal, it can withstand 500V/50Hz,leakage current 0.75mA for 1 min without the breakdown | ||||
Insulation resistance | The resistance between the charged part and nonconductive metal part tested by megohm meter of 500V ≥20MΩ | ||||
Sealing test | Static pressure | Air | High pressure | 1MPa | |
Low pressure | 0.02MPa | ||||
Cold water | High pressure | 1.2MPa | |||
Low pressure | 0.02MPa | ||||
Hot water | High pressure | 0.8MPa | |||
Low pressure | 0.02MPa | ||||
Service life | ≥1000000 cycles(CJ/T 194-2004) |
Temp of working environment | 1ºC--60ºC | Permissible limiting pressure(water) | ≤1.2MPa |
Humidity of working environment | 35%-90% RH | Mounting direction | It is mounted in vertical. The inclination do not exceed 15 degrees |
Storage temp | -5--80ºC( no freezing state) | Storage humidity | 25%--95% RH(No condensation state) |