Silane SiH4 Gas Sensor Detector Environmental Control Toxic Gas Electrochemical

China Silane SiH4 Gas Sensor Detector Environmental Control Toxic Gas Electrochemical, Find details about China Membrapor, Sih4 Sensor from Silane SiH4 Gas Sensor Detector Environmental Control Toxic Gas Electrochemical

Model NO.
SiH4/M(C)(S)-range-(S)
Sensitivity
High
Certification
RoHS
Customized
Customized
Output
TTL/4-20mA/RS485
Transmitter Board
Integrated/Seperated
Wire
Two or Three Wire
Detecting Range
Selectable
After Sale Service
Yes
Trademark
FAD
Transport Package
Transparent Plastic Box
Specification
20-41mm
Origin
China
HS Code
8542330000
Model NO.
SiH4/M(C)(S)-range-(S)
Sensitivity
High
Certification
RoHS
Customized
Customized
Output
TTL/4-20mA/RS485
Transmitter Board
Integrated/Seperated
Wire
Two or Three Wire
Detecting Range
Selectable
After Sale Service
Yes
Trademark
FAD
Transport Package
Transparent Plastic Box
Specification
20-41mm
Origin
China
HS Code
8542330000
Gas Module Introduction
FAD gas module with two/three wire TTL/0-20mA/RS485 output, integrates toxic gas sensor + transmitter board. Adopting imported advanced electrochemical gas sensors, it has features of high accuracy, long lifetime, high stability and high anti-interference. The module is designed to prevent circuit reversed connection, high voltage, high current and lightning.
 
Gas Module Feature
- Long lifetime imported advanced electrochemical sensors
- High accuracy op ams, power supply IC, stable and sensitive
- Detect low or high concentration toxic gases precisely
- High anti-interference ability
- Over range protection, reversed polarity protection and lightning protection
- Low power consumption with a standard 4-20mA two/three-wire signal output
- Interface: pump, diffusing, flange, flange thread types
- 12-36VDC operating voltage

Silane SiH4 Gas Sensor Detector Environmental Control Toxic Gas Electrochemical

Sensor Detecting Range Selection
Detecting range (ppm)/SizeMiniatureCompactSlimStandard
0-50 ppm SiH4/M-50SiH4/C-50SiH4/S-50-SSiH4/S-50

Sensor Performance Characteristics(take SiH4/C-50 as an example)
Operation Principle 3-Electrode Electrochemical
Nominal Range0 - 50 ppm
Maximum Overloadn.d.
Expected Operation Life2 years in air
Output Signal
1200 ± 400 nA/ppm
Resolution (Electronics dependent) <0.2 ppm
Temperature Range-20 °C to 50 °C
Pressure RangeAtmospheric ±10%
Pressure CoefficientNo data
T90 Response Time< 60 sec
Relative Humidity Range15 % to 90 % R.H. non-condensing 1)
Typical Baseline Range (pure air, 20°C)
0 ppm to -1 ppm
Maximum Zero Shift(20°C to +40°C)N.D.
Typical Long Term Output DriftN.D.
Recommended Load Resistor10 Ohm
Bias VoltageNot recommended
Repeatability< 2 % of signal
Output LinearityLinear

Sensor Physical Characteristics
Weight~ 13 g
Position SensitivityNone
Storage LifeSix months in container
Recommended Storage Temperature5 °C - 20 °C
Warranty Period12 months from date of dispatch

Sensor Cross-sensitivity Data
Interfering Gas Concentration(ppm)Reading(ppm)
CO2000
H2S58
SO251
H22000
PH322

Performance data conditions: 20 °C, 50% RH, 1013 mbar
Silane SiH4 Gas Sensor Detector Environmental Control Toxic Gas Electrochemical
Module Parameters
Module typeGM-I2(3)-M/C/S-**-****/G/P/F/FL
Detected gasToxic gas
Detecting principleElectrochemistry
SamplingDiffusing  pump  flange  thread
Responding time30s~40s(of the sensor)
Module accuracy≤±3%FS(actual concentration, higher accuracy depends on specified sensors)
Module repeatability≤±2% FS
Module linear error≤±2% FS
Module zero temperature drift≤±2% (FS/year)
Module operating temperature-40~80°C
Module humidity0-95%RH(non-condensation)
Sensor operating temperature-20°C~50°C
Sensor humidity0-90%RH(non-condensation)
Signal outputTTL/4-20mA /RS485   (two or three wire)
Transmitting distance1000 meters(RS485)
Operating voltageDC 12-36V
Maximum power≤0.8W
Size80*48mm
Explosion proofIntrinsic safe
Connection cableRVVP3 x 1.5mm²

Module applications
Petroleum, petrochemical, metallurgy, chemical, electricity, telecom, gas, mining, pharmacy, municipal wastewater treatment, indoor environment, atmospheric environmental protection, transit equipment, transportation facilities, tunnel safety and underground parking, leak detection, safety and environmental control