China Kema Sub 3200watts 24VDC and 5000watts 48VDC off Grid Hybrid Solar Inverter with Built in MPPT 80A, Find details about China Inverter, Solar Inverter from Kema Sub 3200watts 24VDC and 5000watts 48VDC off Grid Hybrid Solar Inverter with Built in MPPT 80A
ITEM | Model | N-SUB1500 | N-SUB3000 | N-SUB3500 | N-SUB5000 | N-SUB5500 | N-SUB5000P |
INPUT | RATED POWER | 1.5KW | 3KW | 3.5KW | 5KW | 5.5KW | 5KW |
Voltage | 230 VAC | ||||||
Selectable Voltage Range | 170-280 VAC (For Personal Computers) | ||||||
90-280 VAC (For Home Appliances) | |||||||
Frequency Range | 50 Hz/60 Hz (Auto sensing) | ||||||
OUTPUT | Voltage | 230VAC ± 5%(Bat Mode) | |||||
Surge Power | 2 times Rated power for 5 seconds | ||||||
Overload Protection | 5s@≥150% load; 10s@110%~150% load | ||||||
Efficiency,PV to INV. | 97% (Peak) | ||||||
Efficiency,Battery to INV. | 94%(Peak) | ||||||
Transfer Time | 10 ms (For Personal Computers) ; 20 ms (For Home Appliances) | ||||||
Waveform | Pure sine wave | ||||||
Parallel Extension | infeasible | infeasible | infeasible | infeasible | infeasible | Max 9PCS, | |
Battery type | AGM/Flooded/user defined , Lithium ( need to mention when needed ) | ||||||
BATTERY & AC CHARGER | Battery Voltage | 24 VDC | 24 VDC | 24 VDC | 48 VDC | 48 VDC | 48 VDC |
Floating Charge Voltage | 27 VDC | 27 VDC | 27 VDC | 54 VDC | 54 VDC | 54 VDC | |
Overcharge Protection | 33 VDC | 33 VDC | 33 VDC | 63 VDC | 63 VDC | 63 VDC | |
Charge Current (Max) | 60A | 80 A | 80A | 80 A | 80A | 80 A | |
SOLAR CHARGER | PV Array Power (Max) | 2000W | 4000W | 5KW | 5000W | 6KW | 5000W |
MPPT Range | 120 ~ 450 VDC | ||||||
PV Array VOC (Max) | 500 VDC | ||||||
Charging Current (Max) | 80A, AC+Solar adjustable | 80A, AC+Solar adjustable | Max100A AC+Solar | 80A, AC+Solar adjustable | Max100A AC+Solar | 80A, AC+Solar adjustable | |
Efficiency (Max) | 0.98 | ||||||
Display | LED | Line Mode or bat Mode, Charging status ,Fault | |||||
LCD | Vac HZ, Charge Amp W, PV VDC Amp W , Load % VA W Amp ,bat % VDC ,,setup , Fault code, working mode, | ||||||
Setup/Adjust parameter | Solar power /utility power/Battery priority, united Charge Current , AC Charge Amp, AC input range, VAC HZ, Bat VDC back to utility power, BAT VDC back to Bat Mode, Charge Source select ,Alarm on off , overload bypass, Bulk/ Floating Charge VDC, Bat Low Cut VDC , equalization Charge VDC / mins / days, | ||||||
output working Mode | utility power priority | default. Utility power priority, Solar and battery as backup when utility power not available | |||||
Solar priority(SUB Mode) | solar power priority, utility power supplement to load when solar power is not enough , utility not available, battery supplement to load. Working on daytime while No Bat | ||||||
SBU priority | Solar power priority, When Solar power is not enough,battery to supplement.when battery power is not enough , utility power to load. Working on daytime while No Bat | ||||||
OPERATING ENVIRONMENT | Humidity | 5% to 95% Relative Humidity(Non-condensing) | |||||
Operating Temperature | 0°C - 55°C | ||||||
Storage Temperature | -15°C - 60°C | ||||||
Communication interface | USB/RS232/GPRS/WIFI,App availiable | ||||||
Product size | L*W*H | 448*295*105mm | |||||
Net Weight (kgs) | Kg | 8.5 | 9 | 9 | 10 | 10 | 10 |
Carton size | L*W*H | 590*390*208mm | |||||
Carton weight | Kg | 11KG | 11KG | 11 | 11.8Kg | 11.8 | 11.8Kg |
Working Mode | Solar Charging | AC Charging | Load Supply Priority | Battery Disconnected | ||
1 | 2 | 3 | ||||
utility power priority | always when shine | selectable | Utility power | Solar | Battery | Working when solar available |
Solar priority(SUB Mode) | always when shine | selectable | Solar | Utility power | Battery | Working when solar available |
SBU priority | always when shine | selectable | Solar | Battery | Utility power | Working when solar available |
please reference above working mode |
Load Capacity | Solar Energy | Utility power | Battery Energy | REMARK |
3KW | 3KW | 0 | 0 | the KW is a hypothesis for Explain well.solar panel be assumed to be 100% efficiency |
3KW | 2KW | Share the 1KW, Priority Order depended the working mode | ||
3KW | 4KW | 0 | recharge 1KW |
Why Choose us ?
1) TOP 5 manufacturer, 15 years Rich experience , 8000 square meters, 200 employees ,15 Engineers.
2) QC control,100% inspection before shipment .
3) 10 years experience in international bidding together with dealer.
We constantly improve the design and provide new products. And we are the only one
who can sign "Quality Warranty"&"On Time Delivery Warranty" with clients.
Service
· OEM/ODM with LOW MOQ!
· Provide training on design/installation and maintenance of dealer's office or factory every year.
· Complete set system design and installation supporting.
FAQ:
Q:Are you factory or trade company?
A:We have two factories in China. we make UPS/Inverter/Battery in Foshan city which is close to Guangzhou.
We make Solar Panel in Ningbo city .
Q:How to Collect the goods together from Two Factory?
A:We will collect the goods together. And arranging the shipment from Ningbo or Guangzhou.
Q:Can I get a sample to check quality before mass order?
A:Sure, don't hesitate to contact me.
Q:How long is the warranty?
A:One year or Two years for electronic products and batteries. 10 years for Solar panel.
More details be shown in the Performa Invoice .
Q:What's the delivery time?
A:Usually for sample order within one week, for mass order 10-30days.
Q:Do you provide OEM/ODM service?
A:we have experienced R&D team, welcome to place OEM/ODM orders.
Q:What's the payment terms?
A:T/T,W/U or LC options.
Factory Display
Sales And Engineer Display
Customer Praise
Projects Display