Item | Model | RT1K | RT1KS | RT2K | RT2KS | RT3K | RT3KS |
Capacity | VA / Watts | 1KVA/ 0.9KW | 1KVA / 0.8KW | 2KVA/ 1.8KW | 2KVA / 1.6KW | 3KVA/ 2.7KW | 3KVA / 2.4KW |
Input | Normal voltage | 220VAC/ 110VAC | |||||
220V Voltage range | a) (110±5 ~ 300±5) VAC when Load at 0-60% | ||||||
b) (120±5 ~ 300±5) VAC when Load at 60-70% | |||||||
C) (140±5 ~ 300±5) VAC when Load at 70-80%, | |||||||
D) (160±5 ~ 300±5) VAC when Load at 80-100% | |||||||
110V Voltage range | 80-150VAC | ||||||
Power Factor | 0.97 | ||||||
Frequency range | Normal 50HZ/60HZ±4, 40~70Hz(set by winpower) | ||||||
Output | Voltage range | 220/110VAC+-2% | |||||
Frequency range | 50Hz/60Hz+-0.2 (Battery mode) | ||||||
Wave form | Pure Sine Wave | ||||||
Transfer time | 0 ms (AC mode and battery mode) | ||||||
Transfer time: 4ms (typical 2.5ms),AC mode and bypass mode | |||||||
Distortion (Full Load) linear load | ≤3% | ≤3% | ≤4% | ≤4% | ≤4% | ≤4% | |
Degree of distortion (Full Load) nonlinear load | ≤6% | ≤6% | ≤7% | ≤7% | ≤7% | ≤7% | |
Overload capacity | >108% 30s turn to bypass mode; >150%, 300ms turn to bypass | ||||||
Load peak ratio | 3:1(max) | ||||||
Battery Pack | Model | UPS Internal | N/A | BP807 | N/A | BP807 | N/A |
Type | Maintenance free valve regulated lead acid (VRLA) battery | ||||||
Battery voltage | 36VDC | 36VDC | 96VDC | 96VDC | 96VDC | 96VDC | |
Battery number | 3*12V*7.2AH | External | 8*12V*7.2AH | External | 8*12V*7.2AH | External | |
Backup time (Full load) | >5Mins | depended on battery | >9Mins | depended on battery | >5Mins | depended on battery | |
Backup time (Half load) | 14Mins | depended on battery | 21Mins | depended on battery | 15Mins | depended on battery | |
Recharge time | 90%capacity after 5 hrs charging | depended on battery | 90%capacity after 5 hrs charging | depended on battery | 90%capacity after 5 hrs charging | depended on battery | |
Bypass | Automatic while overload or ups fail. | ||||||
Before ON | Default ON. Workable set by Winpower | ||||||
Voltage Range | Default 80-260V, workable set by WinPower to 80-286V | ||||||
Display | LED | Load level / Battery level / Battery mode / Line mode / Inverter , Bypass ,Over load , Fault | |||||
LCD | Option | BAT % VDC, Input VAC HZ, Output VAC HZ , Load % | |||||
Audible Alarm | Battery Mode | Beeping every 4 seconds (re-settable) and every second when battery low | |||||
Overload | Beeping twice every second | ||||||
Fault | Beeping Continuously | ||||||
Communications | RS-232 Interface,With monitoring software,USB Option,SNMP NetAgent Option | ||||||
Surge protection | RJ-45 I/O port available for network or Fax/Modem | ||||||
Environment | Working temperature | - 20ºC~40ºC | |||||
Humidity | 0-95% non-condensing | ||||||
UPS Product size | WxDxH (mm) | 483 x 450 x 88 (2U) | |||||
UPS CTN size | WxDxH (mm) | 605*610*270 | |||||
UPS CTN weight | KG/PCS | 20/1PCS | 15/1PCS | 18/1PCS | 18.2/1PCS | 19/1PCS | 19.2/1PCS |
BP Product size | WxDxH (mm) | 483 x 450 x 88 (2U) | |||||
BP CTN size | WxDxH (mm) | 605*610*270 | |||||
BP CTN weight | KG/PCS | included in ups | N/A | 305/1PCS | N/A | 35/1PCS | N/A |
REMARK | RT*K --- Standard Type, RT*KS---- Long Time Type. |