Water-Proof Limit Switch (LX-D4C-1232)

China Water-Proof Limit Switch (LX-D4C-1232), Find details about China Water-Proof Limit Switch, Limit Switch from Water-Proof Limit Switch (LX-D4C-1232)

Model NO.
LX-D4C-1232
Operating Speed
1mm~1m/S
Operating Frequency 1
Mechanical:120 Operations/Min
Operating Frequency 2
Electrical:20 Operations/Min
Conventional Thermal Current
5A
Electrical Prameter
AC250V/1A DC220V/0.3A
Vibration
Malfunction:10Hz~55Hz, 1.5mm Double Amplitude
Shock
Mechanical Resistance:500m/S2; Malfunction:200m/S2
Working Life
Mechanical:107 Min.; Electrical:105
Degree of Protection
IP67
Temperature
-10~+70 Centigrades
Trademark
CLIN
Origin
Wenzhou, China
HS Code
8536500000
Model NO.
LX-D4C-1232
Operating Speed
1mm~1m/S
Operating Frequency 1
Mechanical:120 Operations/Min
Operating Frequency 2
Electrical:20 Operations/Min
Conventional Thermal Current
5A
Electrical Prameter
AC250V/1A DC220V/0.3A
Vibration
Malfunction:10Hz~55Hz, 1.5mm Double Amplitude
Shock
Mechanical Resistance:500m/S2; Malfunction:200m/S2
Working Life
Mechanical:107 Min.; Electrical:105
Degree of Protection
IP67
Temperature
-10~+70 Centigrades
Trademark
CLIN
Origin
Wenzhou, China
HS Code
8536500000
Water-Proof Limit Switch (LX-D4C-1232)

General Introduction

LX-D4C series water-proof limit switch is suitable for the circuit of 50/60Hz, AC250V or DC220V to control, limit, location, travel, signal or program conversion. This series limit switches have strong dust-, liquid- and oil-resistance with compact size, sensitive action and high accuracy. This series products conform to GB14048.5 IEC60947-5-1 standards.

Technical Specification
 
Operating Speed1mm~1m/s
Operating FrequencyMechanical:120 operations/min;Electrical:20 operations/min
Contact Resistance200mΩ max (initial value with  3 m VCTF cable)
Insulation Resistance100mΩ min(at 500VDC)
Conventional Thermal Current5A
Electrical PrameterAC250V/1A DC220V/0.3A
Dielectric Strength1890V, 50/60Hz for 1min between terminals of the same polarity
2500V, 50/60Hz for 1 min between terminal and non-current carrying metal parts
2500V, 50/60Hz for 1 min between terminal and ground
Vibration malfunction:10Hz~55Hz, 1.5mm double amplitude
Shockmechanical resistance:500m/s2; malfunction:200m/s2
Ambient EnvironmentTemperature:minus10centigrade~70 centigrade(no ice); Humidity:<95%RH
Working LifeMechanical:107 Min.; Electrical:105
Degree of ProtectionIP67
 
 
ModelOperating Force maxReleasing Force minPretravel max Overtravel minMovement Differential Operating Position
LX-D4C-12205.69N(580gf)1.47N(150gf)25°40°/
LX-D4C-123117.65N(1800gf)4.41N(450gf)1.8mm0.2mm3mm24.9±1mm
LX-D4C-123217.65N(1800gf)4.41N(450gf)1.8mm0.2mm3mm34.3±1mm
LX-D4C-123317.65N(1800gf)4.41N(450gf)1.8mm0.2mm3mm34.3±1mm
LX-D4C-12501.47N(150gf)/15°///
LX-D4C-12691.47N(150gf)/15°///

Outline Dimension

Water-Proof Limit Switch (LX-D4C-1232)