UV-C 254nm Wavelength Industrial UV Sterilizer Water Treatment Equipment

China UV-C 254nm Wavelength Industrial UV Sterilizer Water Treatment Equipment, Find details about China Water Treatment, UV Sterilizer from UV-C 254nm Wavelength Industrial UV Sterilizer Water Treatment Equipment

Model NO.
YLC-700
Water Inlet Hardness
Less Than 120mg/Liter
Water Inlet Turbidity
Less Than 1 Ntu
Water Inlet Iron Content
Less Than 0.3 Mg/Liter
Water Inlet Manganese Content
Less Than 0.05 Mg/Liter
Cleaning Model
Hand-Cleaning, Rod Cleaning, Automatic Motor
Lifespan of UV Lamp
9000 to 12000 Hours
Control System
Control Box, PLC, Remote Control, etc
Water Output
1 to 500 Cubic Meter Per Hour
Trademark
YLD
Specification
to be customized
Origin
Jiangyin, China
HS Code
842121999
Model NO.
YLC-700
Water Inlet Hardness
Less Than 120mg/Liter
Water Inlet Turbidity
Less Than 1 Ntu
Water Inlet Iron Content
Less Than 0.3 Mg/Liter
Water Inlet Manganese Content
Less Than 0.05 Mg/Liter
Cleaning Model
Hand-Cleaning, Rod Cleaning, Automatic Motor
Lifespan of UV Lamp
9000 to 12000 Hours
Control System
Control Box, PLC, Remote Control, etc
Water Output
1 to 500 Cubic Meter Per Hour
Trademark
YLD
Specification
to be customized
Origin
Jiangyin, China
HS Code
842121999

UV Swimming Pool Water Disinfection Equipment
 
Ultraviolet (UV) water Sterilizer
Ultraviolet (UV) water purification systems are thought to offer the most cost-effective way of protecting residential drinking water against biological contaminants. UV purification systems can be used to protect against water-borne viruses, bacteria, molds and pathogenic disease-causing microorganisms such as giardia and cryptosporidium. Even viruses such as the hepatitis virus, which are known to be highly resistant to chlorine-treated water, can be relatively easily eliminated through UV treatment.

AAA:

01.What is the source of raw water to be treated?
--is it underground water or well water?or river water ,other source?
02.What is the capacity(m3/hour) you required for this sterilizer?
--most IMPORTANT requirement.
03.What will the treated water be used for?
--for human drinking or industry purpose?
04. What is the power supply in your country?
--220V 50Hz?

Is UV 100% effective?
 
UV disinfection typically offers a 99.99% reduction in both bacteria and virus and is more effective than chemical disinfection processes at destroying viruses.
 
Does UV remove E. coli?
 
Yes, E. coli requires a UV dose of between 6 to 12 mJ/cm2 to achieve 4-log disinfection. This is well within the capabilities of the Sterilight UV system.
 
How much does it cost to operate? UV systems are extremely economical to operate.
 
A typical household UV system operates on the same power requirements as a 40 watt light bulb!
 
Will UV change the taste or smell of my water?
 
UV is a physical disinfection process, no additives are required. It does not change the taste or odour of the water. It simply provides safe reliable disinfection.



 Technical parameters sheet 
modelcapacityPowerinlet-outletreactorpanelAnchorG weight

m³/hourwattmmL×W×H
screwKg
YLCn-0050.3161/2″30×6×11

5
YLCn-0081251/2″47×6.3×11

10
YLCn-0502401″100×9×20Φ8.9×25
(d×L)
69×4×Φ125
YLCn-1506801+1/4″100×11×23
×Φ130
YLCn-20081201+1/2″100×15.9×30Φ8.9×45
(d×L)
69×7×Φ135
YLCn-300121602″100×15.9×32
69×7×Φ140
YLC-050240DN25/1″100×8.9×3025×30×12
(W×H×D)
60×4×Φ145
YLC-150680DN32/11/4″100×10.8×30
60×4×Φ150
YLC-2008120DN40/11/2″×
60×7×Φ160
YLC-30012160DN50/2″100×15.9×40
×Φ170
YLC-36015200DN65/21/2″100×15.9×40
60×7×Φ1120
YLC-50020240DN65/21/2″×
60×11×Φ1.2130
YLC-60025280DN80/3″100×21.9×50
60×11×Φ1.2140
YLC-70030320DN100/4″100×21.9×50
60×11×Φ1.2150
YLC-100040360DN100/4″100×21.9×50
×Φ1.2160
YLC-120050400DN125/5″100×21.9×50
60×11×Φ1.2180
YLC-150060420×
120×16×Φ1.4210
YLC-200080560DN150/6″170×27.3×57
120×16×Φ1.4220
YLC-2500100700DN150/6″170×27.3×5760×128×30
×
120×16×Φ1.4275
YLC-3000125840DN150/6″170×27.3×57
120×16×Φ1.4300
YLC-40001501120DN200/8″173×32.5×65
120×20×Φ1.6325
YLC-50002001400DN200/8″173×37.7×72
120×22×Φ1.6350
YLC-70003002100175×42.6×80
120×24×Φ2.0400
YLC-10K4002520DN250/10″176×52.9×9560×150×40
×
120×22×Φ2.2475
YLC-15K6003080DN300/12″176×78×110
120×32×Φ2.4600
YLC-20K8003920DesignatedDesignatedDesignatedDesignated
YLC-25K10004760DN350/14″DesignatedDesignatedDesignatedDesignated
installation instructions

1.Before install this equipment,please test the voltage for connection.normal running for UV lamp and ballast requires 240V.
2.There should be a 1.5 meter space for spared at each end(at least one end)for disassemble the quartz tube and UV lamp.then connect the water inlet and outlet
3.After connected the inlet and outlet pipe,then release the water to check whether there is any leakage at the nut connection.if it is leakage,screw the nut or check the sealing ring is cracked or not.pipe.please do not use too much force when screw the nut to avoid any cracking of tube.
4.The supporting frame must be grounding.
5.The UV lamp is inserted into the quartz tube through the nut with holes. the electric control panel is connected with 4-core plug and UV lamp. while connecting, two hands should handle the pin end and 4 core plug end respectively. Insert into  plug slowly to avoid possible break-up because of corrosion.