China My-E010 Medical Device Multifunctional Anesthesia Machine, Find details about China Multifunctional Anesthesia Machine, Medical Anesthesia Device from My-E010 Medical Device Multifunctional Anesthesia Machine
1. Main body:High-strength engineering plastic rack, light,
beautiful and corrosion resistant
2. Scope of application adult, child
3. Gas source O2: 0.27~0.55MPa N2O: 0.27~0.55MPa
4. Flow meter O2: 0.1~1.0L/min 1.1~10L/min
N20: 0.1~1.0L/min 1.1~10L/min
5. O2, N2O linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
6. Flow rate of rapid oxygen supply 25~75L/min
7. Low oxygen pressure alarm There will be sound alarm when the oxygen
pressure < 0.2MPa
8. Vaporizer it has the function of automatic compensation based on pressure, temperature,
and flow rate. The regulation range of evaporator concentration is 0~5 vol%.
Among Halothane,Enflurane,Isoflurane and Sevoflurane,two can be chosen for application as required
by the customer. And vaporizers that are imported with original packaging are also available.
9. Respiratory circuit working mode: all-close, semi-close, semi-open APL: 0.5~7 kPa
10. Respiratory Bellows bellows for adults, bellows for children tidal volume range:0~1,500 ml
11. Display mode High-definition 5.7" LCD screen display
12. Ventilation mode IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH
13. Ventilation parameters Tidal volume 50~1500 ml
Rate 2~99 bpm
SIMV rate 2~20 bpm
Inspiratory trigger pressure -1.0~2.0 kPa
PEEP 0~2.0 kPa
Pressure range 1.0~6.0 kPa
SIGH 1.5 times the inspiratory time
14. Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total
respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure
15. Monitoring of oxygen concentration (21%~100%)
16. Security Alarm System
Oxygen Concentration alarm upper limit setting range (50%~100%)
low limit setting range (15%~50%)
Airway pressure alarm upper limit setting range 1.0~6.0 kPa
low limit setting range 0.4~2.0 kPa
Per-minute ventilation volume alarm upper limit setting range 3.0~30L/min low limit setting range
1.0~10L/min
Sustained high-pressure alarm it will give alarm when stress have consistently been higher than 2.5 kPa
Suffocation alarm it will give sound and light alarm if there is no tidal volume input for 15 seconds
Power alarm
17. Power AC 220V±10% 50Hz±1 (UPS, Storage battery)
18. (Mechanical Arms)
19. (End-expiratory CO2 monitoring)
Product name | MY-E010 medical device Multifunctional Anesthesia Machine |
Brand name | MAYA |
Packaging Details | Carton box for MY-E010 medical device Multifunctional Anesthesia Machine |
Delivery Detail | |
Payment Terms | T/T, Western Union, Money Gram |
Port | Guangzhou |