FUJI China Factory Vvvf Control Observation Panoramic Passenger Elevator Home Elevator Machine Room and Machine Roomless, Find details about China Observation Elevator, Observation Lift from FUJI China Factory Vvvf Control Observation Panoramic Passenger Elevator Home Elevator Machine Room and Machine Roomless
Loading capacity | Rated speed | Door open type | Door opening size(W x H)mm | Car size (Ax B) mm | Hoist way size(AH x BH) mm | Machine room size | ||
PIT | OH | (W x D x H)mm | ||||||
450kg | 1.0/1.5 /1.75 | Center | 800x2100 | 1400x850 | 2000x1550 | 1500/1600 | 4500 | 2500x3200x2500 |
630kg | 1.0/1.5 /1.75 | Center | 800x2100 | 1400x1100 | 2000x1750 | 1500/1600 | 4500 | 2500x3600x2500 |
800kg | 1.0/1.5 /1.75 | Center | 800x2100 | 1400x1350 | 2000x2000 | 1500/1600 | 4500 | 2500x3800x2600 |
1000kg | 1.0/1.5 /1.75 | Center | 900x2100 | 1600x1400 | 2200x2150 | 1500/1600 | 4500 | 3000x4000x2600 |
1250kg | 1.0/1.5 /1.75 | Center | 1100x2100 | 2000x1400 | 2600x2150 | 1500/1600 | 4500/4700 | 4000x4500x3000 |
1350kg | 1.0/1.5 /1.75 | Center | 1100x2100 | 2000x1500 | 2600x2250 | 1500/1600 | 4500/4700 | 4000x4500x3000 |
1600kg | 1.0/1.5 /1.75 | Center | 1100x2100 | 2000x1750 | 2600x2500 | 1500/1600 | 4500/4700 | 4000x4500x3000 |
No. | Description name | Description | No. | Description name | Description |
1 | Static electricity protection | Eliminate static electricity raised from running of steps. | 11 | Over-load protection | Protection against risk of motor continually over-load. |
2 | Emergency stop button | Push the emergency stop button to shop the escalator/moving walk against emergency raise. | 12 | Step sagging protection | Protection against risk of steps being breakage and sagging. |
3 | Skirting protection | Protection against risk of foreign bodies being jammed into clearance between steps and skirting. | 13 | Broken step chain protection | Protection against risk of steps being breakage or under elongation. |
4 | Handrail entry safety protection | Protection against risk of foreign bodies being jammed into handrail entry. | 14 | Comb teeth safety protection | Protection against risk of foreign bodies being trapped at the point where the step enter the comb. |
5 | Main drive chains safety protection | Protection against risk of drive chains being breakage or undue elongation. | 15 | Handrail speed and broken handrail monitor | It detects the handrail speed and monitors the broken handrail. |
6 | Over-speed protection | Protection against risk of speed being over 20% of rated speed. | 16 | Skirting anti-clamp device | It sets protection brush in the skirting on both sides of the step. |
7 | Under-speed protection | Protection against risk of speed less than over 80% of rated speed. | 17 | Step missing detection | It detects the step missing in the stairway. |
8 | Un-intentional reversal protection | Protection against risk of unintentional reversal protection. | 18 | The brake opens the monitor switch | It monitors whether the brake opens or not in during the escalator running. |
9 | Floor-plate monitor switch | When the pit cover plate opens,it cuts off safety circuit and stops the escalator safety switch. | 19 | Handwheel and handwheel protection cover open safety | During the use of handwheel,when open the handwheel and the handwheel protection cover,the safety switch will cut the safety circuit against escalator running. |
10 | Short circuit protection | Protection against risk of short circuit. | 20 | Lack of phase,error phase protection | Protection against risk of phase failure. |