China Solar Power Inverter 1kw to 6kw Inverter Ig3115e with 1000W to 6000W, Find details about China Inverter, Power Inverter from Solar Power Inverter 1kw to 6kw Inverter Ig3115e with 1000W to 6000W
MODEL | IG3115CL 1-6KW Pure Sine wave Output Inverter | ||||||
1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |
Input Wave form | Sine wave (utility or generator) | ||||||
Nominal Voltage | 230Vac (120Vac optional) | ||||||
Low voltage trip | 90v ±4% & 184v/154v ±4% | ||||||
Low voltage re engage | 100v ±4% & 194v/164v±4% | ||||||
High voltage trip | 140v ±4% & 253v ±4% | ||||||
High voltage re engage | 135v ±4% & 243v±4% | ||||||
Nominal Input Frequency | 50Hz/ 60Hz (auto detection) | ||||||
Frequency range | 47Hz~65Hz | ||||||
Output Wave form | (Bypass mode)same as input | ||||||
Efficiency on line transfer mode | ≥95%+ | ||||||
Line transfer time | 10ms Typical | ||||||
Bypass without battery connected | Yes | ||||||
Inverter specification/output | |||||||
Output wave form | Pure sine wave | ||||||
Output continuos power watts | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 |
Output continuos power VA | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 |
Power factor | 0.9-1.0 | ||||||
Nominal Output Voltage rms | 230Vac (120Vac optional) | ||||||
Output Voltage regulation | +/- 10%rms | ||||||
Output frequency | 50Hz ± 0.3Hz or 60Hz ± 0.3Hz | ||||||
Safety Certification | >88% | ||||||
Surge ratings | 3000 | 4500 | 6000 | 9000 | 12000 | 15000 | 18000 |
Short circuit protection | Yes,fault after 1 secs | ||||||
Inverter specification/input | |||||||
Nominal input voltage | 12V/24V/48V | ||||||
Minimum start voltage | 10V/20V/40V | ||||||
Low battery alarm | 10.5V/21V/42V | ||||||
Low battery trip | 10V/20V/40V | ||||||
High voltage alarm | 16V/32V/64V | ||||||
Power saver | Same switched on/off on remote | ||||||
Charger mode specification | |||||||
Output voltage | Dependent on battery type | ||||||
Charge current | 0-85A MAX | ||||||
Battery initial voltage for start up | 0-15.7v for 12v(*2 for 24v;*4 for 48v;*8 for 96v) | ||||||
Over charge protection shutdown | 15.7v for 12v(*2 for 24v;*4 for 48v;*8 for 96v) | ||||||
Charger curves(4stage constant curren) | battery types | ||||||
4 step digital controlled progressive charge | |||||||
Battery type | Fast V Fast V(*2 for 24v;*4 for 48v) | ||||||
Gel U.S.A | 14 13.7 | ||||||
A.G.M. 1 | 14.1 13.4 | ||||||
A.G.M. 2 | 14.6 13.7 | ||||||
Sealed lead acid | 14.4 13.6 | ||||||
Gel euro | 14.4 13.8 | ||||||
Open lead acid | 14.8 13.3 | ||||||
Calcium | 15.1 13.6 | ||||||
De-sulphation | 15.5 for 4 hrs | ||||||
Remote control/RS232/USB | Yes. Optional |