Double Units Distillation Test Equipment for Petroleum Products

China Double Units Distillation Test Equipment for Petroleum Products, Find details about China Distillation Test Equipment, Double Units Distillation Tester from Double Units Distillation Test Equipment for Petroleum Products

Model NO.
GD-6536A
Gross Weight
63kg
Trademark
GOLD
Transport Package
Standard Wooden Case
Specification
ISO
Origin
Chongqing
HS Code
9031809090
Model NO.
GD-6536A
Gross Weight
63kg
Trademark
GOLD
Transport Package
Standard Wooden Case
Specification
ISO
Origin
Chongqing
HS Code
9031809090
Introduction:

The instrument is designed and made as per GB/T6535 and ASTM D86. 
The instrument is suitable to determine distillation characteristics of natural gasoline, vehicle gasoline, aviation gasoline, jet fuels, special boiling point solvent, naphtha, diesel oil, distillate and similar petroleum products.  


Specifications:

Power supply: AC 220V±10%, 50 Hz;
Heating power of electric furnace: 1000 W×2;
Volume of graduated flask: 100 ml with scale division of 1 ml;
Distillation flask: 125 ml;
Thermometer: Total immersion rod type; their temperature ranges are -2~300ºC, and -2~400ºC; their scale divisions are 1 ºC;
Movable plate for electric furnace: made of SiC; their hole diameters are φ32, φ38, and φ50.
Temperature controller:
(1) Temperature controlling range:  0ºC~60ºC;
(2) Refrigeration device: by a compressor;
(3) Temperature controlling accuracy:  ±0.5ºC;
(4) Temperature display mode: digitally displayed by a LED;
Ambient temperature: ≤+35ºC;
Relative humidity: ≤85%;
Total power consumption: not more than 5000 W;
ItemGD-6536A Distillation Tester
Test standardGB/T6536,  ASTM D86
Suitable forgasoline, jet fuels, special boiling point solvent, naphtha, diesel oil, distillate and other petroleum products
Features Can test two samples simultaneity
Heating power of electric furnace1000 W*2, heating power can be continuously adjusted
Volume of graduated flask100 ml with scale division of 1ml
Distillation flask125 ml
Thermometer-2~300°C, and -2~400°C
Temperature controlling rangeAmbient~400°C
Receiver compartment temperature1 ~ 60°C
Temperature controlling accuracy±0.5°C
Power supplyAC 220V±10%, 50 Hz
Ambient temperature: ≤+35°C≤+35°C
Relative humidity≤85%
Total power consumption≤2500 W