(3 Phase) Current Transformer with Input 60 -200A Output 1A, 5A Class 0.5

China (3 Phase) Current Transformer with Input 60-200A Output 1A, 5A Class 0.5, Find details about China CT, 3-Phase CT from (3 Phase) Current Transformer with Input 60-200A Output 1A, 5A Class 0.5

Model NO.
DASN240
Insulating Medium
Insulating Paper
Installation
Busbar Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Electromagnetic Type
Window Size
3@15*15mm
Class
0.5,1.0,3.0
Input
60-200A
Output
1A,5A
Burden
1.5va,2.5va
Trademark
HEYI
Transport Package
Foam Box
Specification
CE, ROHS
Origin
China
HS Code
8504311000
Model NO.
DASN240
Insulating Medium
Insulating Paper
Installation
Busbar Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Electromagnetic Type
Window Size
3@15*15mm
Class
0.5,1.0,3.0
Input
60-200A
Output
1A,5A
Burden
1.5va,2.5va
Trademark
HEYI
Transport Package
Foam Box
Specification
CE, ROHS
Origin
China
HS Code
8504311000
3 Phase current transformer Dasn240 60/5 - 200/5 Class 0.5 Three Phase CT 3 in 1 Current Transformers
 

DASN240  range of current transformers are combination designed 3 CT in 1, save more space comparing general unit CT,

suitable for primarycurrent 75A to 600A, supporting the use of molded case circuit breaker according to

the rated current size.

Features:

1:Three built in fixing methods: Panel/Din Rail/Busbar

2:Built in hinged terminal cover
3:Perfect matching with MCCB, save more space

4:Primary current from 30A to 600A

Applications:

1: Current measurement, monitoring and protection for electrical wiring and equipment.

2: Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, air-condition equipment and automation - control system.

3: Current, power and energy monitoring device.
4: Relay protection device.

Technical Parameters

Rated Frequency50/60Hz
Withstand voltageAC3kV(1min)
Rated thermal current60ln
Dynamic stability current2.5lth
Rated voltageAC0.72KV
Burden1.2ln
Operating temperature range-10°C-50°C
Prevent combustion levelV0
Accuracy limit classFS5
Secondary current5A,1A


Technical

PictureTypeCurrent ratio BurdenPacking for carton
Accuracy class:1.0
(3 Phase) Current Transformer with Input 60-200A Output 1A, 5A Class 0.5
 
DASN24060/51.536
100/51.536
120/51.536
125/52.536
150/52.536
160/52.536
200/52.536


Dimension
(3 Phase) Current Transformer with Input 60-200A Output 1A, 5A Class 0.5

 

STANDARD: