China 100A Split Smart Sensor Open Core Current Transformer CT, Find details about China Transformer Current, Current Transformer from 100A Split Smart Sensor Open Core Current Transformer CT
Current Ratio | Turns Per Coil | Load Resistance | Accuracy Class | Rated Frequency | Stringing Aperture | ||||||||||
200A/40mA,400A/80mA | 5000 | ≤5Ω | 1 | 50~60Hz | ≤φ17.00mm | ||||||||||
Load Internal Resistance | Withstand Voltage | Primary Side Current | Secondary Side Current | Ratio Difference | Phase Difference | ||||||||||
≤580Ω | >3000 VAC | 0.25A~200A | 0.05mA~4mA | ±0.2 | 35±7' | ||||||||||
Ratio error(A) | 0.1A | 0.25A | 0.5A | 1A | 5A | 20A | 50A | 80A | 100A | 120A | 150A | 180A | 200A | 250A | |
Linearity(‰) | -4.77 | -4.71 | -4.50 | -4.40 | -4.46 | -4.35 | -4.31 | -4.24 | -4.21 | -4.18 | -4.17 | -4.17 | -4.17 | -4.22 | |
Current(A) | 0.1A | 0.25A | 0.5A | 1A | 5A | 20A | 50A | 80A | 100A | 120A | 150A | 180A | 200A | 250A | |
Phase Difference() | 41.5 | 41.7 | 41.8 | 41.6 | 41.2 | 39.7 | 37.5 | 36.0 | 35.1 | 34.4 | 33.6 | 32.8 | 32.5 | 31.6 |