China Factory Price Solar Power Inverter Without Battery 3kVA 2400W, Find details about China Inverter, Inverter Charger from Factory Price Solar Power Inverter Without Battery 3kVA 2400W
Model | PSC 3KVA-24 | PSC 6KVA-48 | PSC 6KVA-96 |
INPUT Voltage Range | 180-270VAC(Nominal) OR 100-270VAC(General/wide) | ||
Rated Output power | 3000VA/2400W | 6000VA/4200W(4800W) | 6000VA/4200W(4800W) |
Surge Rating | 4800W | 8400W | 8400W |
Power factor | 0.8 | 0.7/0.8 | 0.7/0.8 |
Capable of starting electic power | 1.5HP | 2.5HP | 2.5HP |
Norminal Input Voltage | 220/230/240VAC | ||
Norminal Input frequency | 50Hz or 60Hz (Auto detection) | ||
Output Voltage | 220/230/240VAC±10% rms | ||
Output frequency | 50Hz or 60Hz ±1Hz | ||
Norminal Efficiency | >90%(@Norminal DC input;>60% R load) | ||
Over-Load protection | fault after 5s 150% ~200% load | ||
fault after 10s @ 110%~150% load | |||
Norminal Charge current | 10A @ Vi/P<170VAC | 20A(95-175v)gen/wide only | 10A(95-175v) gen/wide only |
20A @ Vi/P=230VAC | 35A(175-275v) @35A setting | 20A(175-275v) @ 20A setting | |
10A @ Vi/P>280VAC | 20A(175-275v) @25A setting | 10A(175-275v) @10A setting | |
Output Wave form | Pure sine wave | ||
Norminal Input Voltage | 24Vdc | 48Vdc | 96Vdc |
Charge voltage | 27Vdc | 54Vdc | 108Vdc |
Over charge protection | Bat.V≥30Vdc, Fault buzzer alarm | Bat.V≥60Vdc, Fault buzzer alarm | Bat.V≥120Vdc, Fault buzzer alarm |
Output short circuit protection | 30A Circuit Breaker | 40A Circuit Breaker | |
Relative Humidity | 5% to 95% non condensing | ||
Operating temperature | 0ºC-45ºC | ||
Storage temperature | -15ºC-60ºC | ||
Altitude optional | Elevation:0-1500m | ||
Dimensions(L×W×H) | 330×269×77mm | 430×350×105mm | |
Net Weight (kg) | 4.9 | 8.5 | 8.5 |