China Induced Draft Counter Flow Nh3 Evaporatives Condensers for Refrigeration Industry, Find details about China Counter Flow Evaporative Condenser, Counter Flow Nh3 Condenser from Induced Draft Counter Flow Nh3 Evaporatives Condensers for Refrigeration Industry
Model | Rated Capacity | Fan | Spraying Pump | Operation Weight | ||||
Qty. | Power | Air Volume | Qty. | Power | Flow Rate | |||
KW | KW | m³/h | KW | m³/h | KG | |||
KEN-100 | 100 | 1 | 1*1.1 | 1*15000 | 1 | 1*1.1 | 1*36 | 1280 |
KEN-150 | 150 | 1 | 1*1.1 | 1*15000 | 1 | 1*1.1 | 1*36 | 1550 |
KEN-200 | 200 | 1 | 1*1.1 | 1*15000 | 1 | 1*1.1 | 1*36 | 2100 |
KEN-230 | 230 | 1 | 1*1.5 | 1*18500 | 1 | 1*1.1 | 1*36 | 2150 |
KEN-280 | 280 | 2 | 2*1.1 | 2*15000 | 1 | 1*1.1 | 1*53 | 2300 |
KEN-320 | 320 | 2 | 2*1.5 | 2*18500 | 1 | 1*1.1 | 1*53 | 2550 |
KEN-350 | 350 | 2 | 2*1.1 | 2*15000 | 1 | 1*1.1 | 1*53 | 2570 |
KEN-380 | 380 | 2 | 2*1.5 | 2*18500 | 1 | 1*1.1 | 1*53 | 2600 |
KEN-430 | 430 | 2 | 2*1.5 | 2*18500 | 1 | 1*1.1 | 1*53 | 3200 |
KEN-480 | 480 | 2 | 2*2.2 | 2*26000 | 1 | 1*1.1 | 1*53 | 3400 |
KEN-520 | 520 | 1 | 1*4 | 1*55000 | 1 | 1*1.5 | 1*70 | 3500 |
KEN-550 | 550 | 1 | 1*5.5 | 1*60000 | 1 | 1*1.5 | 1*70 | 3800 |
KEN-600 | 600 | 1 | 1*4 | 1*55000 | 1 | 1*1.5 | 1*70 | 3850 |
KEN-650 | 650 | 1 | 1*5.5 | 1*60000 | 1 | 1*1.5 | 1*70 | 4200 |
KEN-750 | 750 | 1 | 1*5.5 | 1*80000 | 1 | 1*1.5 | 1*70 | 5380 |
KEN-800 | 800 | 1 | 1*7.5 | 1*90000 | 1 | 1*1.5 | 1*70 | 5800 |
KEN-850 | 850 | 1 | 1*7.5 | 1*90000 | 1 | 1*2.2 | 1*100 | 5850 |
KEN-950 | 950 | 1 | 1*11 | 1*125000 | 1 | 1*2.2 | 1*100 | 7400 |
KEN-1000 | 1000 | 1 | 1*7.5 | 1*90000 | 1 | 1*2.2 | 1*100 | 7500 |
KEN-1080 | 1080 | 1 | 1*11 | 1*125000 | 1 | 1*2.2 | 1*100 | 8200 |
KEN-1100 | 1100 | 2 | 2*4 | 2*55000 | 1 | 1*3 | 1*140 | 8300 |
KEN-1180 | 1180 | 2 | 2*5.5 | 2*60000 | 1 | 1*3 | 1*140 | 8400 |
KEN-1220 | 1220 | 2 | 2*4 | 2*55000 | 1 | 1*3 | 1*140 | 8700 |
KEN-1330 | 1330 | 2 | 2*5.5 | 2*60000 | 1 | 1*3 | 1*140 | 8900 |
KEN-1400 | 1400 | 2 | 2*5.5 | 2*80000 | 1 | 1*4 | 1*180 | 9100 |
KEN-1450 | 1450 | 2 | 2*7.5 | 2*90000 | 1 | 1*4 | 1*180 | 9200 |
KEN-1550 | 1550 | 2 | 2*5.5 | 2*80000 | 1 | 1*4 | 1*180 | 9400 |
KEN-1650 | 1650 | 2 | 2*7.5 | 2*90000 | 1 | 1*4 | 1*180 | 10500 |
KEN-1700 | 1700 | 2 | 2*7.5 | 2*90000 | 1 | 1*4 | 1*180 | 11000 |
KEN-1750 | 1750 | 2 | 2*11 | 2*125000 | 1 | 1*4 | 1*180 | 11900 |
KEN-1800 | 1800 | 2 | 2*7.5 | 2*90000 | 1 | 1*4 | 1*180 | 12300 |
KEN-1900 | 1900 | 2 | 2*11 | 2*125000 | 1 | 1*4 | 1*180 | 13350 |
KEN-2000 | 2000 | 2 | 2*7.5 | 2*90000 | 2 | 1*5.5 | 1*233 | 15000 |
KEN-2160 | 2160 | 2 | 2*11 | 1*125000 | 2 | 1*5.5 | 1*233 | 16400 |
KEN-2200 | 2200 | 4 | 4*4 | 2*55000 | 2 | 2*3 | 2*140 | 16600 |
KEN-2360 | 2360 | 4 | 4*5.5 | 2*60000 | 2 | 2*3 | 2*140 | 16800 |
KEN-2440 | 2440 | 4 | 4*4 | 2*55000 | 2 | 2*3 | 2*140 | 17400 |
KEN-2660 | 2660 | 4 | 4*5.5 | 2*60000 | 2 | 2*3 | 2*140 | 17800 |
KEN-2800 | 2800 | 4 | 4*5.5 | 2*80000 | 2 | 2*4 | 2*180 | 18200 |
KEN-2900 | 2900 | 4 | 4*7.5 | 2*90000 | 2 | 2*4 | 2*180 | 18400 |
KEN-3100 | 3100 | 4 | 4*5.5 | 2*80000 | 2 | 2*4 | 2*180 | 18800 |
Note: For R717 refrigerant, the 'Rated Capacity' based on standard condition: condensing temp. 35degC, wet bulb temp. 24degC. |