Bioevopeak Sample Pre-Treatment Microwave Digestion System, Mds-Tanp

China Bioevopeak Sample Pre-Treatment Microwave Digestion System, Mds-Tanp, Find details about China Microwave Digestion, Microwave Digester from Bioevopeak Sample Pre-Treatment Microwave Digestion System, Mds-Tanp

Model NO.
MDS-TanP
Power Supply
220V
Customization
Available
Trademark
Bioevopeak
Transport Package
Carton
Origin
China
Model NO.
MDS-TanP
Power Supply
220V
Customization
Available
Trademark
Bioevopeak
Transport Package
Carton
Origin
China
Bioevopeak Sample Pre-Treatment Microwave Digestion System, Mds-TanpBioevopeak Laboratory Use Microwave Digestion
Features

Microwave Digestion

Patented structure-the prefect combination of high-throughput digestion and high-pressure digestion.

MDS-TanP  comes standard with 40 high-pressure digestion vessels, achieving fully enclosed high-pressure digestion. It can also meet the digestion needs for tough samples. Having the fixed quantity pressure-relief design and automatic over-pressure-relief protection to prevent vessel burst due to high pressure, MDS-TanP is the perfect combination of high-throughput digestion and high-pressure digestion.

High-strength aerospace composite fiber outer vessel, perfect within mechanical strength and corrosion-resistance

The high-strength aerospace composite fiber outer vessel-Xtra Fiber has the advantages of unbreakable, racking-free and tearing-free, and its comprehensive performance in pressure resistance and anti-corrosion is superior to the traditional PEEK outer vessel. PFA spray completely wraps the composite fiber and provides excellent corrosion resistance (especially at the edge of the outer vessel). The pressure resistance can reach 70 MPa (about 10000 psi) and the temperature resistance can reach 600 °C, so as to ensure the user's operation safety under extreme conditions.

Safety Bolt design, being fully sealed and digested while achieving quantified safety pressure relief

Combining nearly 30 years of industry experience, Sineo adopts Safety Bolt structure design to ensure that the digestion vessel is completely sealed and leak-free under normal working conditions. In the overpressure state, the safety bolt is automatically lifted to complete the pressure relief and ensure the safe operation. Under normal operating conditions, the safety bolt will not break or no need for replacement, no safety hazards.

Optical-fiber and IR temperature measurement system, having precise temperature control and simultaneous monitoring of abnormalities to ensure accurate results and experiment safety

MDS-TanP comes standard with multicoreopticald fiber and dual-beam full scan infrared temperature measurement system. The fiber has a diameter of 2mm and a Teflon protective layer on the outside. The bend has a small radius of curvature, which is resistant to folding and has high flexibility. The service life is 5 times longer than that of single-core fiber. The fiber-optic temperature control system achieves precise temperature control while avoiding the antenna effect of the conventional metal sensors in the microwave field. Full vessel temperature scanning can effectively monitor the abnormal situation of digestion. If there is temperature abnormality, the workstation immediately stops the microwave emission and turns on the alarm.

High precision semiconductor pressure sensor with high corrosion resistance and high mechanical strength

MDS-TanP Microwave Digestion Workstation adopts improved semiconductor pressure sensor. The whole pressure conduction path is treated with anti-corrosion treatment. While the pressure is accurately measured, the service life of the sensor is greatly extended. This technology effectively improves the reliability of the workstation.

Dual magnetron inverter control system ensures consistent sample digestion

MDS-TanP Microwave Digestion Workstation adopts two-dimensional dual magnetron system and high-frequency closed-loop PID control, thereby realizing microwave continuous non-pulse output, more uniform microwave field in cavity, higher energy utilization rate, and consistent sample digestion.

Powerful and convenient software assistant in accordance with FDA 21 CFR Part 11

The software is designed and developed in Android system. It has the functions of electronic signature, hierarchical authority and audit trail, and complies with the relevant regulations of FDA 21 CFR Part 11. Provided with 8G local storage space, built-in expert method library, and 7-inch LCD touch screen which can display the temperature and pressure curve during operation in real time. The software automatically recognizes the turntable model and counts the number of vessels, saving manual counting and cumbersome input and making the experiment easier and more convenient.

Support by the cloud service function, expanding the storage capacity while keeping the data in safe.

MDS-TanP Microwave Digestion Workstation is provided with the cloud service function, wherein data, method and other information are kept and shared. Unlimited expansion of data storage is available while making no compromise on the data security. The users can download the latest version of software from public cloud server. The system is updated online and the user experience is greatly improved.

The digest-er integrated dual LCD screen display, clearly showing the digestion state and experiment process

English operating software can display parameters such as temperature, pressure, time, and steps in real time. Ready to switch to the coordinate curve interface at any time and help observe the real-time temperature and pressure changes during the experiment. This helps the users to understand the experimental process and improve the digestion solution. In addition, through the 5-inch video observation window, the inside of the furnace chamber can be observed more clearly and comprehensively.

A variety of supporting tools available, easy to take Experiment

A variety of convenient operation tools can reduce the workload of the operator and improve the efficiency of sample preparation. For example, the flexible trolley can help the experiment personnel to easily put the high-flux turntable filled with the sample into or out of the cavity, avoiding direct contact between the worker and the digestion vessels, and ensuring the safety of the experiment personnel. The electrical torque wrench makes it easy to close and open the digestion vessels.

 

Specification
ModelMDS-TanP
Power220~240VAC 50/60Hz 20A
Microwave source2450MHz, dual magnetron design, high energy microwave emission
Installation power3800W
Maximum output power2000W
Microwave cavity66L large volume 316L stainless steel cavity, inner and outer multilayer corrosion-resistant Teflon spray
Batch numbers12 Vessels; 40Vessels
Explosion-proof safety door designSafety door designed based on 3-D directional explosion-proof mechanism, anti-microwave leakage integrated with anti-flow groove structure design
Pressure monitoring systemHigh-precision novel semiconductor pressure sensor with pressure control range: 0~10MPa (1450psi), control accuracy ±0.01MPa
Temperature monitoring systemNon-metallic multi-core optical fiber + full tank IR dual temperature measurement, temperature control range: -40~305 °C, temperature control accuracy: ±0.1 °C
Passive protection systemCOT real-time temperature and pressure anomaly monitoring system can automatically alarm and cut off microwaves to protect users' safety when temperature and pressure anomalies occur in any one of the reaction vessels.
SoftwareAndroid system; video SOP; built-in method library; cloud service, data storage and sharing; Wi-Fi remote connection, etc.
Communication portsWith USB port and network cable port
Video MonitoringWith an internal camera for real-time monitoring of the operation of the digestion vessel in the chamber
Furnace exhaust systemCool to room temperature for less than 15 minutes
Microwave extraction moduleNormal pressure extraction experiment
Working environment0~40ºC / 15~80%RH
Overall physical size / net weight600*685*660 (Width*Depth*Height)/62kg
Vessel typeSelf-pressure relief vesselHigh pressure digestion vessel
Batch numbers12 Vessels40 Vessels
Outer Vessel materialAerospace composite fiberAerospace composite fiber
Rotor frame structureIndependent Frame vessel structureHigh-strength integrated Carousel
Reaction vessel volume100mL75mL
Maximum design temperature300ºC300ºC
Highest design pressure10MPa (1450psi)10MPa (1450psi)
ImageBioevopeak Sample Pre-Treatment Microwave Digestion System, Mds-TanpBioevopeak Sample Pre-Treatment Microwave Digestion System, Mds-Tanp
Packaging & Shipping

 

Bioevopeak Sample Pre-Treatment Microwave Digestion System, Mds-Tanp

Certifications

Bioevopeak Sample Pre-Treatment Microwave Digestion System, Mds-Tanp

Company Profile

Bioevopeak Sample Pre-Treatment Microwave Digestion System, Mds-TanpBioevopeak Sample Pre-Treatment Microwave Digestion System, Mds-Tanp

FAQ

Q: How about quality of the goods?
A:

  1. All the running products comply with CE standards.
  2. Independent quality inspection team, conducting multiple inspections and random inspections from parts supply to product dispatch.
  3. Well-known third-party testing service available, such as SGS, BV, and TUV, etc.
 
Q: What are your pre- and after-sales services?
A:
  1. Timely reply to pre-sales enquiries
  2. Real-time update of manufacturing and shipment status
  3. Contracted third-party maintenance company in over 60 countries

Assured availability of parts supply for 10 years at least

Q: Is OEM service available.
A: Most of the running products are available for OEM customization, including logo, package and function, if attainable, customization.
 
Q: How long is the lead time:
A: Generally, the lead time for most stocked products is about 7~15 days, vary by models and production schedule. For those non-stocked products, the manufacturing lead time is around 20 days.