China Tank Weighing Load Cell Qh-61f, Find details about China Tank Weighing Weighing Sensor, Tank Weighing Load Cell from Tank Weighing Load Cell Qh-61f
Specifications: | |||
Capacity | t | 1~100 | |
Safe overload | %FS | 120 | |
Ultimate overload | %FS | 150 | |
Rated output | mV/V | (1.0~1.5) ± 0.02 | |
Excitation voltage | Vdc | 10~15 | |
Combined error | %FS | ± 0.05 | ±0.1 |
Zero unbalance | %FS | ± 1 | |
Non-linearity | %FS | ± 0.05 | ± 0.1 |
Hysteresis | %FS | ± 0.05 | ± 0.1 |
Repeatability | %FS | ± 0.03 | ± 0.05 |
Creep | %FS/30min | ± 0.05 | ± 0.05 |
Input resistance | Ω | 760 ± 30 | |
Output resistance | Ω | 701 ± 5 | |
Insulation resistance | M Ω | ≥ 5000 @ 50 Vdc | |
Operating temperature range | ºC | -20 ~ +70 | |
Compensated temperature range | ºC | -10 ~ +40 | |
Temperature coefficient of SPAN | %FS/10ºC | ± 0.03 | ± 0.03 |
Temperature coefficient of ZERO | %FS/10ºC | ± 0.02 | ± 0.03 |