China High Voltage Vacuum Relay Voltage Restrained Overcurrent Protection Behlke Switch, Find details about China High Voltage Relay, Mini Relays from High Voltage Vacuum Relay Voltage Restrained Overcurrent Protection Behlke Switch
Features | ||||||
1,Breakdown Voltage Is DC.10KV 2,4 PCB type,2 PCB+2 Wire type | ||||||
Ordering information | ||||||
CRSTHV-14KV-A-W 1 2 3 | ||||||
1,Part number: CRSTHV-14KV 2, Contact Form:A:Normal Open,B:Normal Close 3,Teminal Type:NIL:PCB type,W:PCB+Wire | ||||||
Contact Rating | ||||||
Contact Arrangement | 1A(1H)(SPST NO); 1B(1B)(SPST NC); | |||||
Contact Rating | 50W | |||||
Max.Switching Voltage (DC or AC PEAK) Max | DC.7KV, | |||||
Breakdown Voltage Min | DC.10KV | |||||
Max.Switching Current | 2.0A | |||||
Max.Carry Current | 3.0A | |||||
Operation Life | Electrical | DC.10000V-1mA 0.5X106 MIN Operations(R.L.) | ||||
Mechanical | 1*108 MIN Operations(R.L.) | |||||
Coil Parameter (23ºC) | ||||||
Coil voltage (VDC) | Coil Resistance Ω±10% | Normal Current(mA) | Release voltage VDC(Min) (10% of rated voltage) | Pick up Voltage VDC(Max) (80% of Rated voltage) | ||
Rated | Max | |||||
5 | 6.5 | 50 | 100.0 | 0.5 | 4.0 | |
12 | 15.6 | 200 | 60.0 | 1.2 | 9.6 | |
24 | 31.2 | 720 | 33.3 | 2.4 | 19.2 | |
Operation condition | |
Contact Resistance | 150mΩ MAX.(Initial) |
Breakdown Voltage | Open Contacts DC.10KV MIN Contacts to COIL DC.15KV MIN |
Insulation Resistance | Open contacts 1X109ΩMIN.(DC.100V) Contacts to coil 1X109ΩMIN.(DC.100V) |
Electromotive Capacitance | 2.0pF MAX. |
Operate Time | (Incl.bounce)4.0mS MAX.(at Normal Voltage) |
Release Time | 2.0mS MAX.(at Normal Voltage) |
Vibration | 20G(0~55Hz.1.5mm) |
Shock | 30G(11mS,1/2Sin Wave) |
Operating Temperature | -20ºC-+70ºC |
Storage Temperature | -35ºC-+90ºC |