Low Temperature Ram Impact Test Apparatus
Product details: Model ZLT-DCJ2:
To determine the mechanical strength of insulated cords, cables, couplers, insulating sleeves and enclosures in the cold, according to IEC60811-1-4 figure 2, IEC60811-506:2012 figure 1.
Standard outfit:
1 steel block, height 40mm, width approx 200mm, mass 10kg,
2 columns, inclusive of upper crossbeam with fixing screw,
1 guide rod, threeedged, with slightly rounded edges, for heights of fall up to 100mm with maximum height of sample 40mm,
1 intermediate piece of steel, mass 100g,diameter 20mm, bottom side rounded R=300mm.
1 set mass of the falling weight is 100g, 200g, 300g, 400g, 500g, 600g, 750g, 1000g, 1250g, 1500g, impact height:10~250mm.
2 intermediate piece, of steel, mass 100 g, with striking bolt of diameter 20 mm and 6 mm, for impact tests according to IEC60811-506 Fig 1
Mass of hammer for power cables in fixed installations
overall diameter |
| Mass of the hammer |
4.0 |
| 100g |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|