DC-AC Current Clamp Meter

China DC-AC Current Clamp Meter, Find details about China Digital Clamp Multimeter, Digital Clamp on Meter from DC-AC Current Clamp Meter

Payment Terms: L/C, T/T, Western Union
PROVA-11 AC/DC mA True RMS Clamp Meter
Super High Resolution DC 1mA, AC 0.1mA
One Touch Zero for DCA
True RMS

CM-01 DC/AC Clamp Meter
High Resolution DC/AC 10mA
23 mm Large Jaw Diameter
One Touch Zero for DCA adjustment

PROVA-5601 Clamp-on Ground Resistance Tester
Non-Contact Ground Resistance Measurement
No Auxiliary Electrode Needed
Jaw Diameter Φ 23 mm (5601)
0.025 - 1500 Ohm
0.2mA - 30A(5601), True RMS
116 Sets of Memory
Programmable Hi and Lo Alarm
Programmable Data Logging

PROVA-15 AC/DC mA Current Probe
High Resolution DC 1mA, AC 0.1mA
Connect to an Oscilloscopes to observe Current Waveform
Connect to Chart Recorder/Datalogger/ DMM to Record Current Data
PROVA-5601     Ground Resistance (Auto range)
Range  Resolution  Accuracy of Reading 1, 2 
0.025 - 0.250 Ω 0.002 Ω ± 1.5% ± 0.05 Ω
0.250 - 1.000 Ω 0.02 Ω ± 1.5% ± 0.05 Ω
1.001 - 9.999 Ω 0.02 Ω ± 1.5% ± 0.1 Ω
10.00 - 50.00 Ω 0.04 Ω ± 2.0% ± 0.3 Ω
50.01 - 99.99 Ω 0.04 Ω ± 2.0% ± 0.5 Ω
100.0 - 200.0 Ω 0.4 Ω ± 3.0% ± 1.0 Ω
200.1 - 400.0 Ω 2 Ω ± 5.0% ± 5 Ω
400.1 - 600.0 Ω 5 Ω ± 10% ± 10 Ω
600.1 - 1500 Ω 20 Ω ± 20%
1 Loop resistance noninductive, external field < 200 A/m, external electrical field < 1 V/m, conductor centered.
2 Resistance Measurement Frequency: 1.667KHz, 3.333KHz(optional)
Ground/Leakage Current (Auto range, 50/60 Hz, True RMS, Crest Factor < 3.5)
Range  Resolution  Accuracy of Reading 
0.200 - 1.000 mA 0.001 mA ± 2.0% ± 0.05 mA
1.00 - 10.00 mA 0.01 mA ± 2.0% ± 0.03 mA
10.0 - 100.0 mA 0.1 mA ± 2.0% ± 0.3 mA
100 - 1000 mA 1 mA ± 2.0% ± 3 mA
0.20 - 4.00 A 0.001A ± 2.0% ± 0.03A
4.00 - 30.00 A(5601) 0.01A ± 3.0% ± 0.03A
General Specification
Accuracy of Resistance Calibration Plate ±0.5% 
Data Logging Capacity 116 records 
Data Logging Interval 1 to 255 seconds 
Conductor Size 23mm /0.90"(5600,5601) 
Jaw Opening 27mm /1.06"(5600,5601) 
Battery Type 9V IEC 6 LR61 (Alkaline) 
Display Type 4 digits 9999 counts LCD 
Overload Indication OL 
Battery Life 3000 measurements 
Range Selection Auto 
Power Consumption 40mA 
Sampling Time 0.5 seconds 
Operating Temperature 0ºC to 50ºC (14ºF to 122ºF ) Operating Humidity: Less than 85% RH 
Storage Temperature -20ºC to 60ºC (-4ºF to 122ºF ) Storage Humidity: Less than 75% RH 
Dimension( 5600, 5601 ) 257mm (L) x 100mm(W) x 47mm(H),10.1" (L) x 3.9"(W) x 1.9"(H) 
Weight( 5600, 5601) 640g/1.41lbs 
Accessories Resistance Calibration Plate x 1 
Battery 9V (Installed) x 1 
Carrying Box x 1 
Users Manual x 1 
PROVA-15    Range Output Sensitivity Accuracy
DCA 0-400mA DC 1mV/A 1mA/mV DC +/- 2.0% +/- 1mV
DCA 0-4A DC 100mV/A 10mA/mV DC +/- 1.0% +/- 0.5mV
DCA 0-30A DC 10mV/A 0.1A/mV DC +/- 1.0% +/- 0.3mV
ACA 0-400mA AC 1mV/A 1mA/mV AC +/- 2.0% +/- 0.5mV
ACA 0-4A AC 100mV/A 10mA/mV AC +/- 1.5% +/- 0.8mV
ACA 0-30A AC 10mV/A 0.1A/mV AC +/- 1.5% +/- 0.3mV
Power Source: 2 X 1.5V AA UM3 Batteries
Current Consumption: 10mA
Operating Condition: -10 ºC  to 50 ºC  at 85% max. RH