PROVA-5601 Ground Resistance (Auto range) | ||
Range | Resolution | Accuracy of Reading 1, 2 |
0.025 - 0.250 Ω | 0.002 Ω | ± 1.5% ± 0.05 Ω |
0.250 - 1.000 Ω | 0.02 Ω | ± 1.5% ± 0.05 Ω |
1.001 - 9.999 Ω | 0.02 Ω | ± 1.5% ± 0.1 Ω |
10.00 - 50.00 Ω | 0.04 Ω | ± 2.0% ± 0.3 Ω |
50.01 - 99.99 Ω | 0.04 Ω | ± 2.0% ± 0.5 Ω |
100.0 - 200.0 Ω | 0.4 Ω | ± 3.0% ± 1.0 Ω |
200.1 - 400.0 Ω | 2 Ω | ± 5.0% ± 5 Ω |
400.1 - 600.0 Ω | 5 Ω | ± 10% ± 10 Ω |
600.1 - 1500 Ω | 20 Ω | ± 20% |
1 Loop resistance noninductive, external field < 200 A/m, external electrical field < 1 V/m, conductor centered. | ||
2 Resistance Measurement Frequency: 1.667KHz, 3.333KHz(optional) | ||
Ground/Leakage Current (Auto range, 50/60 Hz, True RMS, Crest Factor < 3.5) | ||
Range | Resolution | Accuracy of Reading |
0.200 - 1.000 mA | 0.001 mA | ± 2.0% ± 0.05 mA |
1.00 - 10.00 mA | 0.01 mA | ± 2.0% ± 0.03 mA |
10.0 - 100.0 mA | 0.1 mA | ± 2.0% ± 0.3 mA |
100 - 1000 mA | 1 mA | ± 2.0% ± 3 mA |
0.20 - 4.00 A | 0.001A | ± 2.0% ± 0.03A |
4.00 - 30.00 A(5601) | 0.01A | ± 3.0% ± 0.03A |
General Specification | |
Accuracy of Resistance Calibration Plate | ±0.5% |
Data Logging Capacity | 116 records |
Data Logging Interval | 1 to 255 seconds |
Conductor Size | 23mm /0.90"(5600,5601) |
Jaw Opening | 27mm /1.06"(5600,5601) |
Battery Type | 9V IEC 6 LR61 (Alkaline) |
Display Type | 4 digits 9999 counts LCD |
Overload Indication | OL |
Battery Life | 3000 measurements |
Range Selection | Auto |
Power Consumption | 40mA |
Sampling Time | 0.5 seconds |
Operating Temperature | 0ºC to 50ºC (14ºF to 122ºF ) Operating Humidity: Less than 85% RH |
Storage Temperature | -20ºC to 60ºC (-4ºF to 122ºF ) Storage Humidity: Less than 75% RH |
Dimension( 5600, 5601 ) | 257mm (L) x 100mm(W) x 47mm(H),10.1" (L) x 3.9"(W) x 1.9"(H) |
Weight( 5600, 5601) | 640g/1.41lbs |
Accessories | Resistance Calibration Plate x 1 |
Battery 9V (Installed) x 1 | |
Carrying Box x 1 | |
Users Manual x 1 |
PROVA-15 Range | Output | Sensitivity | Accuracy |
DCA 0-400mA | DC 1mV/A | 1mA/mV DC | +/- 2.0% +/- 1mV |
DCA 0-4A | DC 100mV/A | 10mA/mV DC | +/- 1.0% +/- 0.5mV |
DCA 0-30A | DC 10mV/A | 0.1A/mV DC | +/- 1.0% +/- 0.3mV |
ACA 0-400mA | AC 1mV/A | 1mA/mV AC | +/- 2.0% +/- 0.5mV |
ACA 0-4A | AC 100mV/A | 10mA/mV AC | +/- 1.5% +/- 0.8mV |
ACA 0-30A | AC 10mV/A | 0.1A/mV AC | +/- 1.5% +/- 0.3mV |
Power Source: 2 X 1.5V AA UM3 Batteries | |||
Current Consumption: 10mA | |||
Operating Condition: -10 ºC to 50 ºC at 85% max. RH |