Cell Cycle and Apoptosis Detection Kit

China Cell Cycle and Apoptosis Detection Kit, Find details about China Cell Apoptosis Detection Kit, Cell Cycle and Apoptosis Analysis Kit from Cell Cycle and Apoptosis Detection Kit

Model NO.
G1700-50T
Habit Appellation
Special Reagent
Application
Industry, Scientific Research
Property
Biochemical Reagent
Trademark
Servicebio
Specification
50T
Origin
China
Model NO.
G1700-50T
Habit Appellation
Special Reagent
Application
Industry, Scientific Research
Property
Biochemical Reagent
Trademark
Servicebio
Specification
50T
Origin
China
Product Information
 
Product NameCat. No.Specification
Cell Cycle and Apoptosis Detection KitG1700-50T50T
Cell Cycle and Apoptosis Detection Kit

Product introduction:

The cell cycle refers to the whole process that a cell goes through from the completion of one division to the end of the next division. It is mainly divided into two phases: the interphase and the mitosis (M phase); the intercellular phase is mainly composed of the prophase of DNA synthesis (G1 phase). ), DNA synthesis phase (S phase) and late DNA synthesis (G2 phase). The sequence of changes in the entire cell cycle can be represented by G1→S→G2→M. First, the G1 period: the cell mainly synthesizes RNA and protein and other substances to prepare the cell for material and energy to enter the S phase; then enters the S phase: the cell begins to synthesize DNA and some histones, and the cell's DNA content begins to increase; finally To G2 stage: At this time, the DNA content of the cell has become twice that of the G1 period, and DNA replication has stopped, and a large amount of protein and other substances are synthesized to enter the mitosis period; if G0 (cells temporarily stop dividing and differentiation period) , Quiescent phase)/G1 phase, the DNA content in the cell is 1N; then the DNA content in the cell in the G2 phase is 2N; and the S phase cell in the G1 and G2 phase, the DNA content is between 1N and 2N; and In apoptotic cells, the nucleus will undergo condensation and DNA fragmentation, resulting in the loss of some genomic DNA fragments, so its DNA content is less than 1N. The so-called sub-G1 peak appears on the fluorescence image of flow cytometry, that is, apoptotic cells. peak. Therefore, the cycle and state of the cell can be judged according to the content of cell DNA.

Apoptosis can also be detected by observing the changes in light scattering of cells with a flow cytometer. When a cell undergoes apoptosis, apoptotic bodies are produced due to the condensation of cytoplasm and chromatin and nuclear fragmentation, which changes the light scattering properties of the cell. In the early stage of apoptosis, the chromatin shrinks, the cell density increases, and the forward angle light scattering color is significantly reduced; in the late stage of apoptosis, the cells produce apoptotic bodies, and the forward angle light scattering and lateral angle light scattering are significantly reduced.

The Cell Cycle and Apoptosis Analysis Kit uses the classic Propidium staining method to detect and analyze the cell cycle and apoptosis. Using propidium iodide can be embedded in double-stranded DNA and make it fluorescent, and the fluorescence intensity is proportional to the content of double-stranded DNA; combined with the regular changes in DNA content in different cell cycles, it can distinguish the cell cycle And status. This kit can be used for cell cycle and apoptosis detection of tissue cells, adherent or suspended cells (if it is used for tissue cell cycle and apoptosis detection, the tissue must be digested into a single cell state before the detection can be performed).

Storage and transportation
Transport in wet ice; store in the dark at -20°C, and store in staining buffer at 4°C; valid for 12 months.

Component
 
Component NumberComponentG1700-50T
G1700-1PI staining solution (50×)500 μL
G1700-2RNase A reagent (50×)500 μL
G1700-3Staining Buffer25 mL
Product User Manual1pc


Experiment preparation

1. Cell culture medium containing serum;

2. Trypsin digestion solution (G4001 is recommended);

3. PBS buffer (G4202 recommended);

4. 75% ethanol.

Operation Steps:

1. Cell sample preparation (the number of cells is controlled at 1×105~1×106)

1.1. For adherent cells: remove the culture medium, add trypsin digestion solution to digest the cells, observe the cells to become round and loose under the microscope, add an appropriate amount of cell culture medium containing serum to stop the digestion, gently blow the cells away to make the cells Suspension; transfer the suspension to a centrifuge tube, centrifuge at 1000 g for 3-5 min, discard the supernatant, and retain the cell pellet; then rinse the cell pellet with pre-cooled PBS buffer for 1-2 times, centrifuge and discard the supernatant in the same way , Keep the cell pellet.

1.2. For suspended cells: directly transfer the cells to a centrifuge tube, centrifuge at 1000 g for 3-5 min, discard the supernatant, and retain the cell pellet; then rinse the cell pellet with pre-cooled PBS buffer for 1-2 times, and centrifuge in the same way Discard the supernatant and save the cell pellet.

1.3. For tissue cells: cut the tissue into small pieces as much as possible, select trypsin, collagenase and other digestive enzymes to digest the tissue pieces according to the source of the tissue, and filter with a 100-300 mesh screen to obtain a single cell suspension; after filtering Transfer the cell suspension to a centrifuge tube, centrifuge at 1000 g for 3-5 min, discard the supernatant, and save the cell pellet; then rinse the cell pellet with pre-cooled PBS buffer for 1-2 times, centrifuge and discard the supernatant in the same way. Cell pellets.

2. Cell sample fixation

2.1. Add 1 mL of 75% ethanol pre-cooled on ice to the collected cell pellet samples, and gently blow the cells to make them fully contact;

2.2. Fix the cells at 4ºC for 30 min or longer (usually fixing for 2 h or more can ensure the staining effect, and fixing for 12-24 h may be more effective, which can improve the staining effect).

2.3. After fixing for a certain period of time, centrifuge the cells at 1000 g for 3-5 min, remove the ethanol fixative, and retain the cell pellet;

2.4. Tap the bottom of the centrifuge tube to disperse the cells, resuspend and wash the cells in PBS buffer, centrifuge at 1000 g for 3-5 min, discard the supernatant to collect the cell pellet;

3. Preparation and dyeing of dyeing working fluid

3.1. Prepare the dyeing working solution according to the following table and avoid light. The amount of preparation can be increased or decreased in the same proportion according to the use requirements (the finished dyeing working solution can be stored at 4°C in a short time, please use it within the same day);
 
 1pc sample5pcs samples10pcs samples
Staining buffer480 μL2.4 mL4.8 mL
PI Staining Solution (50×)10 μL50 μL100 μL
RNaseA Reagent (50×)10 μL50 μL100 μL
Total Capacity500 μL2.5 mL5 mL

3.2. Tap the bottom of the centrifuge tube to disperse the cells precipitated in step 2.4, and then add 500 μL of the prepared staining working solution, gently pipetting to disperse the cells and mix with the staining working solution;

3.3. Incubate at 37°C for 30 minutes in the dark, and then use flow cytometry for detection.

4. Flow detection and analysis
A flow cytometer was used to detect the red fluorescence at the excitation wavelength of 488nm, while detecting the light scattering. Use appropriate analysis software for cell DNA content analysis and light scattering analysis.

Notes:

1. Fluorescent dyes have fluorescence quenching problems, so try to avoid light during use and storage;

2. Before the experiment, it is recommended to synchronize the cell cycle to avoid the large repetitive difference caused by the different cell cycle;

3. The experimental cell planting density should not be too high or too low to prevent contact inhibition or density dependence; 4. When handling PI staining solution, pay attention to protection and avoid direct contact with the human body or inhalation;

5. Please wear lab coat and disposable gloves during operation.

The product is for scientific research purposes only, not for clinical diagnosis!
Cell Cycle and Apoptosis Detection KitCell Cycle and Apoptosis Detection KitCell Cycle and Apoptosis Detection KitCell Cycle and Apoptosis Detection KitCell Cycle and Apoptosis Detection Kit