Four in One Function Apf Module

China Four in One Function Apf Module, Find details about China Power Factor Correction, Statcom from Four in One Function Apf Module

Model NO.
APF
HS Code
8536200000
Model NO.
APF
HS Code
8536200000

    SVG Static Var Generator is used as comprehensive power quality improvement for power distribution system transformers side, which have the functions of power compensation, harmonic control and three phase unbalance governance simultaneously. Compared with conventional capacitor compensation scheme, it is precise, two-way, fast reactive power compensation capabilities, and to eliminate the risk of capacitive system harmonics; Compared with the traditional SVG program, it can resolve the problem of harmonic and reactive power.
 

Main Parameter:
Rated Voltage:0.4kV,0.48kV,0.55kV,0.69kV
Frequency:60/50Hz+/-5%
Efficiency:>=98%
Response Time:<5ms
Telecom. Port:RS485,wifi,relay-module(customized)
Telecom Protocal:Modbus
Protection Grade:IP20
Noise:<60db(beyond 2meter)

Heat dissipation:Air cooling

Main functions
maintain receiving end voltage, strengthen system voltage stability
compensate system reactive power, improve power factor, reduce line loss, save energy and reduce cost
suppress voltage fluctuation and flicker
suppress three phase unbalance
compensate both inductive and capacitive loads to achieve PF0.99 and avoid less and over compensation
Fast Response :
Fast response is implemented by SVG modules.The SVGs in the SVGC show the advantage of the electronic power switch. In the legacy SVC, the thyristor only serves as a fast switch, but cannot implement high-frequency
Optimal solution to reactive compensation and three-phase unbalanced compensation
Integrating general LC compensation with the latest SVG compensation technology
Integrated Control & Monitoring System (ICMS)with 18 I/O ports to implement flexible LC and SVG applications
PF= 0.99, avoiding over-compensation and under-compensation


Technical advantages
(1)faster response speed
(2)stronger voltage flicker suppress ability
(3)wider operating range
(4)diversified compensation function
(5)excellent harmonic output characteristic
(6)Modular design method
Application:
Hotel,Car park, Car charger station,Car 4S store etc


Specification

ModelOutput
Current
(kVAR)
Electrical
Wiring
Net Weight(kg)Structure
SVGM0.4-35/3(4)a353 phase,3 wires/3 phase,4 wires40
Wall Mounted
 
SVGM0.4-50/3(4)a503 phase,3 wires/3 phase,4 wires40
SVGM0.4-60/3(4)a753 phase,3 wires/3 phase,4 wires45
SVGM0.4-100/3(4)a1003 phase,3 wires/3 phase,4 wires48
SVGM0.4-35/3(4)b353 phase,3 wires/3 phase,4 wires40
Rack Type
SVGM0.4-50/3(4)b503 phase,3 wires/3 phase,4 wires40
SVGM0.4-60/3(4)b753 phase,3 wires/3 phase,4 wires45
SVGM0.4-100/3(4)b1003 phase,3 wires/3 phase,4 wires48