China CNC OEM Thick Exercise 50A Contactor 50A AC Type Contactor 50A AC Contactor, Find details about China AC Contactor, Contactor AC from CNC OEM Thick Exercise 50A Contactor 50A AC Type Contactor 50A AC Contactor
CNC OEM Thick Exercise 50A Contactor 50A AC Type Contactor 50A AC Contactor
Type | CJX2-09 | CJX2-12 | CJX2-18 | CJX2-25 | CJX2-32 | CJX2-40 | CJX2-50 | CJX2-65 | CJX2-80 | CJX2-95 | ||
Rated insulation voltage (Ui) | V | 690 | ||||||||||
Rated thermal current (Ith) | A | 20 | 20 | 32 | 40 | 50 | 60 | 80 | 80 | 95 | 95 | |
Rated operation current (Ie) | AC-3, 380V | A | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 |
AC-3, 660V | A | 6.6 | 8.9 | 12 | 18 | 21 | 34 | 39 | 42 | 49 | 55 | |
AC-4, 380V | A | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | 37 | 41 | |
AC-4, 660V | A | 1.5 | 2 | 3.8 | 4.4 | 7.5 | 9 | 12 | 14 | 17.3 | 21.3 | |
Max. power of 3 phase motor controlled | AC-3, 220V | kW | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 25 |
AC-3, 380V | kW | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | |
AC-3, 660V | kW | 5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | 45 | 55 | |
Electrical life | AC-3 | 10000 t | 100 | 80 | 80 | 60 | ||||||
AC-4 | 10000 t | 20 | 20 | 15 | 10 | |||||||
Mechanical life | 10000 t | 1000 | 800 | 800 | 600 | |||||||
Operation frequency | AC-3 | t/h | 1200 | 600 | 600 | 600 | ||||||
AC-4 | t/h | 300 | 300 | 300 | 300 | |||||||
Matching fuse type | RT16-20 | RT16-20 | RT16-32 | RT16-40 | RT16-50 | RT16-63 | RT16-80 | RT16-80 | RT16-100 | RT16-125 | ||
Matching thermal relay type | JR28-25 | JR28-25 | JR28-25 | JR28-25 | JR28-36 | JR28-93 | JR28-93 | JR28-93 | JR28-93 | JR28-93 | ||
Wiring capacity | mm² | 1.5 | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 16 | 25 | 35 | |
Coil | ||||||||||||
Control power voltage (Us) | AC | V | 36, 110, 127, 220, 380 | |||||||||
Allowed control circuit voltage | Close | V | 85%~110%Us | |||||||||
Open | V | 20%~75%Us(AC) | ||||||||||
Close | VA | 70 | 110 | 200 | ||||||||
Keeping | VA | 8 | 11 | 20 | ||||||||
Loss power | W | 1.8~2.7 | 3~4 | 6~10 | ||||||||
Auxiliary contact | ||||||||||||
Rated thermal current (Ith) | A | 10 | ||||||||||
Rated operation voltage (Ue) | AC-15 | V | 380 | |||||||||
DC-13 | V | 220 | ||||||||||
Rated control capacity | AC-15 | VA | 360 | |||||||||
DC-13 | W | 33 |
Ambient temperature | -5ºC~+40ºC |
Altitude | ≤2000m |
Relative humidity | The maximum temperature of 40 degrees, the air relative humidity not exceed 50%, at a lower temperature can allow for a higher relative humidity, if humidity changes as a result of occasional gel generated,should eliminate it. |
Pollution level | 3 |
Installation category | III |
Installation position | The installation degree of the tilt and vertical plane should not exceed ±22.5°, should be installed in place with no significant impact shaking and vibration |
Installation | The installation of fastening screws can be used,the CJX1-9~38 contactor can also be installed on 35mm standard DIN rail. |