Normal temperature type:-15C~+70C
Hot water type:+70C~+120C
Ambient temperature :up to +40C
XBC Diesel Fire Fighting Pump Group is aplicable for conveying water at room temperature or the liquid resembing water, or for water of fire fighting or others.
Rated Flow Q=10~250 L/S
Rated pressure Mpa=0.3~1.05Mpa
Rev n=1500, 2000, 2200, 2400 r/min
HP P=17.7~243 HP
Inlet diameter DNa=125~450 mm
Outlet diameer DNa=80~350 mm
Allowable working pressure≤ 25 bar
Starting automatically when there is no power supply
Effective
Stable and reliable running
Easy maintaining
Long service life
water supply to fire spraying system
fault phenomenon | failure cause | elimination methods |
1.No power supply or one or two phase power supply is needed | Check all phases of power supply and restore power supply | |
2.Poor contact of ac contactor and burning of coil | Repair or replace contactors | |
can not start | 3. The power switch is not closed, malfunction or damaged | Close the switch and replace it if the power indicator does not turn on |
4. Thermal relay trip or damage | Check whether the motor is blocked, find out the reason and eliminate it.Manual reset is replaced if it cannot be started | |
Water level is too low | Put water in the sink | |
The motor burned | Repair or replace the motor | |
1.Line is loose | Check wiring and tighten connectors | |
2.Frequency converter malfunction | Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting. | |
The manual is normal | 3The frequency converter is damaged | Repair or replace |
Automatic transmission failure | 4.Pressure switch damage | Repair or replace |
5The pressure transmitter is damaged | Repair or replace | |
6.Switch failure | Repair or replace | |
Pump non - suction pressure gauge pointer to beat violently | Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument | Check pipeline and bottom valve, refill water diversion. Tighten air leakage |
The pump consumes too much power | Too much flow, impeller wear | Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow |