Fireman Service Self Contained Breathing Apparatus

China Fireman Service Self Contained Breathing Apparatus, Find details about China Oxygen Breathing Apparatus, Oxygen Respirator from Fireman Service Self Contained Breathing Apparatus

Model NO.
RHZYN240
Expiratory Resistance(PA)
510PA
Inhalation Resistance(PA)
270PA
Fixed Oxygen Supply
1.5L/Min
Automatic Replenishment of Oxygen
90L/Min
Oxygen Supply by Hand
90L/Min
Automatic Supply Valve Opening Pressure
160PA
Exhaust Valve Opening Pressure
570PA
Trademark
HCXF
Transport Package
Carton
Specification
Fixed oxygen supply(L/ min): 1.50
Origin
China
Model NO.
RHZYN240
Expiratory Resistance(PA)
510PA
Inhalation Resistance(PA)
270PA
Fixed Oxygen Supply
1.5L/Min
Automatic Replenishment of Oxygen
90L/Min
Oxygen Supply by Hand
90L/Min
Automatic Supply Valve Opening Pressure
160PA
Exhaust Valve Opening Pressure
570PA
Trademark
HCXF
Transport Package
Carton
Specification
Fixed oxygen supply(L/ min): 1.50
Origin
China

Fireman Service Self Contained Breathing Apparatus

In accordance with ga632-2006 "positive pressure fire oxygen respirator" standard.Suitable for long - term use in toxic and harmful environment.Positive pressure type, with high temperature resistance, flame retardant, anti-corrosion, waterproof, good air tightness and other properties.Use time 4 hours.

Protection performance within rated protection time:
O2 concentration in inhalation(%):>21%;
CO2 concentration in inhalation(%):0.94%;
suction temperature(ºC):34.3ºC;          Expiratory resistance(Pa):510Pa;
inhalation resistance(Pa):270Pa;
Oxygen performance:
Fixed oxygen supply:1.5L/min;            Automatic replenishment of oxygen:90 L/min;
Oxygen supply by hand:90 L/min;        Automatic supply valve opening pressure:160Pa;
Exhaust valve opening pressure:570Pa;
heat resistance:
High Pressure system air tightness:No leakage within 30 min;
Air tightness of low pressure system: its pressure drop value within 1 min:10pa;
O2 concentration in inhalation(%):>21;        CO2 concentration in inhalation(%):0.40;
suction temperature(ºC):33.4;          Expiratory resistance(pa):590;
inhalation resistance(pa):310;
Fixed oxygen supply(L/ min):1.50;
Automatic replenishment of oxygen(L/ min):90;   Oxygen supply by hand(L/ min):100;
pressure gage:
air leakage(L/ min):15.5;
Mask performance:
The total field of vision(%):82.9;
Binocular vision(%):70;             Below the horizon(°):>35;
Effective volume of air bag or breathing chamber(L):5.2;
Pressure alarm:
The intensity of sound level(dB(A)):87;          Sound time(S):50;
Maximum air consumption(L/ min):3.1;
exhalation valve:
Reverse leakage(L/ min):0.1;     Ventilation resistance(pa):10;
inhalation valve:
Reverse leakage(L/ min):0.1;     Ventilation resistance(pa):10.