High Accuracy Thermocouple with Diatomite Sleeves for Measuring The Temperature

China High Accuracy Thermocouple with Diatomite Sleeves for Measuring The Temperature, Find details about China Thermocouple, Accurate from High Accuracy Thermocouple with Diatomite Sleeves for Measuring The Temperature

Port: Tianjin, China
Payment Terms: T/T
Refractoriness (℃): 1580< Refractoriness< 1770
Type: Refractory Material
Shape: Pipe
Material: Diatomite
Product Description:
Non splashing fast thermocouple with a protective paper tube is mainly composed of a temperature probe and a non splashing paper tube, which is used for measuring the temperature of the molten metal liquid. Install the fast thermocouple on the temperature measuring gun and return the secondary instrument pointer (or digital display) to zero. This indicates that the contact is good and measurement can be performed.

Product Features:
High measurement accuracy
Fast Response
Lightweight structure
Easy to use
Protection tube length can be customized
For measuring the temperature of molten steel and high-temperature molten metal

Product Parameters:
Product
Name
ModelsGraduationAllowable ToleranceRecommended Use temperatureResponse TimeMeasured RateUsage countRemarks
Non-Splash ThermocoupleQR-KS604FJAS±31650ºC2-5S98%4-6The length of thermocouple can be customerd according to customers'requiremeng
R1650ºC
B1750ºC


Product Instructions:
1. According to the object and range of measurement, choose the appropriate protection of the length of the paper tube and the applicable temperature gun.

2. Install the fast thermocouple on the temperature measuring gun and return the secondary instrument pointer (or digital display) to zero. This indicates that the contact is good and measurement can be performed.
3. The depth of the hot thermocouple inserted into the molten steel should be 300-400mm. Do not measure the wall or the slag on the measurement. Do Fast, steady, and accurate. When the secondary instrument gets the result, the gun should be taken immediately, and rapid thermal power should be applied. Even in the molten steel immersion time should not exceed 5 seconds, otherwise, it is easy to burn the temperature gun.
4. After the temperature gun is lifted from the furnace, remove the used thermocouple and install a new one, pause for a few minutes, and prepare for the next measurement. Do not test and disconnect, otherwise, the temperature difference will fluctuate.
Quality Control:
  • All production processes are carried out under the control of the ISO9001 quality management system. During the production process, first ensure that the ambient temperature and humidity are within the required range. From raw material cutting, slurry forming, blank drying, and sintering, workers in each key process must In the process of self-inspection of the hole, size, weight, and appearance of the filter, the inspectors regularly conduct random inspections to ensure that defective products do not flow into the next process.
  • Production inspection: self-inspection by production workers and regular sampling inspection by full-time inspectors. The finished products are fully inspected to ensure that qualified products flow into customers.
  • After-sales service: Damaged during transportation, replenishment will be provided according to the situation. If the product is found to have quality problems during use, after both parties confirm that it is a problem with the filter, our factory will exchange or return the product.
10ppi Zirconia Ceramic Foam Filter for Filtration of Stainless Steel Casting

Service:
First of all, our factory adheres to the principle of quality first. We have a group of professional technical and inspection personnel to focus on product quality control and Technological innovation. For each product, we have strict process inspection and factory inspection. We have a well export experience, to provide customers with professional pre-sales and after-sales service and technical support. The sales process will be active tracking queries, Positively solve the problems in the follow-up use of customers.

Shipping                                                 
Lead time: 10-15days after signed the contract  

Rapid Immersion-Type Thermocouple with 1500mm Protect Tube

FAQ                                                                   

Q: Are you Factory?
A: Definitely, we are factory.  Welcome to visit us!
Q: What Parameters should I provide to you for proper quotation?
A: Application, pore size, dimension, color, quantity, packing requirements, trade terms. 

Q:How can you control your quality? 
A:For each production processing, we have complete QC system for the chemical composition and Physical properties. After production, all the goods will be tested, and we have the quality certificates with ISO9001.

Q: What is your lead time? 
It usually needs about 15- 20 days after receiving the PO.
Q: Do you provide Samples?
A: Yes, our factory provide samples for testing, pls send detail parameters to us. (if customized, with drawing is best) The samples will be charged or free according to the specific requirements.
Q: What's the Payment Terms?
A: We accept T/T, L/C, West Union, etc.

Q: How can I get samples?
A: We are honor to offer you the samples.
Q: What about your Packing?
A: We provide carton box, pallet, etc. OEM packing available too.
Q: Do you have R&D services?
A: Yes, we have R&D department to assist you in new product development.

Q:Does your company accept customization?
A:We accept OEM service.
Q:Can we visit your company?
A:Yes, for sure, you are welcome to visit our company.