Two-Stage Vaccum Oil Filtration Oil Filtering System ZYD
Why choose us?
1. We are one of the largest manufacturers and exporters of oil purifier in China
2. We have more than 10 years experience
3. We offer our customers high quality products at competitive price
4. We offer our customers excellent after-sales service
5. We are not satisfied until our customers are satisfied!
Application
This Transformer Oil dewatering Plant used in:
1, Remove water content from the oil, can deal with the tiny water which cannot be seen by the eyes, the index reach 1-5 PPM.
2, Remove the waste gas from the oil, which made the oil bad smelling and damage the oil specification.
3, The impurities after treat just 5um.
4, With the BZ oil regeneration system, can refine the oil color to colorless, like the water.
5, The breakdown voltage after treated, can be 65-75KV.
6, It is largely used in the area of electric factory, station and company, transformer industry, railway, petrochemical industry, metallurgy etc.
Features
1. The Transformer Oil Dewatering Plant with the high efficiency.
2, The vacuum oil purification is portable and small size, so you can use it everywhere.
3, It is very suitable to operate on line. Also it can be used to dry the electric equipment and input the oil into the electric equipment under the vacuum state.
4,The vacuum oil purification is automatic control.
5, With the alarm, when the temperature and pressure exceed the index, all the parts will stopped.
6. High vacuum limiting vacuum less than 5pa, working vacuum less than 35pa.
7. Environment friendly.
8, Power cost less.
9, Strong and stable.
10, With the engineer installation.
11, We can take the special order as the customer need.
Advantages:
1 Enhance the value of breakdown voltage of oil greatly.
2 Easy handling and maintenance. It is available that online work. The plant can provide the ability of injection oil into the transformers without extra accessory.
3 Lower maintenance and replacement expenses.
4 High efficiency and effectiveness while small size, light weight, and low noise.
Technical Data
Parameters | Unit | ZYD-30 | ZYD-50 | ZYD-100 | ZYD-150 | ZYD-200 | ZYD-250 | ZYD-300 |
Flow | L/H | 1800 | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 |
Working vacuum | MPa | -0.08 ~ -0.099 |
Working Pressure | MPa | ≤0.2 |
Temperature Range | ºC | 20 ~ 80 |
Power | | Three Phase 50Hz380V (according customer requirement) |
Working Noise | dB(A) | 75 | 75 | 75 | 80 | 80 | 80 | 80 |
Heating Power | KW | 27 | 30 | 45 | 60 | 75 | 90 | 120 |
Total Power | KW | 30 | 37.5 | 52.5 | 71.4 | 86.5 | 102.5 | 135 |
Inlet/Outlet | mm | φ25 | φ32 | φ42 | φ50 | φ50 | φ60 | φ60 |
Weight | Kg | 450 | 700 | 1050 | 1400 | 1800 | 2000 | 2200 |
Overall Dimension | Length | mm | 1250 | 1400 | 1640 | 1800 | 2000 | 2050 | 2500 |
Width | mm | 900 | 1050 | 1200 | 1350 | 1450 | 1500 | 1800 |
Height | mm | 1700 | 1990 | 2000 | 2000 | 2100 | 2100 | 2400 |
Oil Data after Treatment
Moisture (water content) | ≤ 3 PPM |
Gas Content | ≤0.1% |
Impurities Degree (Filtration precision) | ≤1u (without free carbon) |
Breakdown Voltage (Dielectric) | ≥80 KV |
PH value | ≥5.5 |
Acid Value | ≤0.03 mg koH/g |
Dielectric Loss Factors | tgδ (90ºC) % ≤0.001 |
Cleanliness | ≤NAS 1638 Grade 6 |