China HD HP Double Pumps Dialysis Machine Price, Hemodialysis Dialysis Machine, Find details about China Dialysis Machine, Hemodialysis Machine from HD HP Double Pumps Dialysis Machine Price, Hemodialysis Dialysis Machine
MC-HD01 main technical parameter
Volume (length× width ×height):370mm×340mm ×1570mm
Weight: about 90kg
Power supply voltage: AC220V±10%
Frequency: 50HZ ~ 60 HZ
Power: 1500W
Blood pump/spare pump:
Flux: 15 ~ 340ml/min (D 6mm)
20 ~ 460 ml/min (D 8mm)
Heparin pump:
Flux: 0.1ml/h~10ml/h(±5%)
Precise: 0.1ml/h
Injector size: 20ml/30ml/50ml 10ml/20ml/30ml (selectable)
Arterial pressure:
display scope:-300mmHg~+300mmHg (±10mmHg)
Venous pressure:
display scope:-50mmHg~+300mmHg (±10mmHg)
Dialysate flow:300ml/min~800ml/min linearity adjustable(+10%)(-5%)
Temperature:35.0ºC~39.0ºC
Resolving rate:0.1ºC
Conductivity:13mS/cm~15.5mS/cm(±0.1 mS/cm)
UF flow scope: 0~1800ml/h(±30ml/h )
0~4000ml/h(optional)
ISO UF flow scope:0~2000ml/h(±30ml/h)
TMP
Scope:-100mmHg~+600mmHg (±20mmHg)
Blood leakage monitor: over 1ml blood per liter dialysate (flow:500ml/min)
Blood level monitor: ultrasonic sensor
Air bubble monitor:
Infrared and response threshold value:Single air bubble of 200u I exists when Blood flux is 200ml/min
Inflow pressure:0MPa~0.6MPa
Inflow temperature: 5ºC~30ºC
Environment temperature: 10ºC~30ºC, Relative humidity≤70%
Rinse/disinfection: chemical disinfection (citric acid,peracetic acid and oxalic acid)
Hot rinse: 80ºC
Back-up power supply: last for 15-30min after electric-cut.
Function
Be applicable of hemodialysis treatment,hemoperfusion,Plasma Exchange,Pure ultrafiltration project.
Touch screen was equipped and it can show Naand UF profiles;In addition,the functions ie.backup power supply,Kt/V,HCO3adjustment,single needle,acetate treatment,pyrogen filter port and net connection ect.are optional.
Clinical Application
Hemodialysis Therapy:same as MC-2000
Pure ultrafiltration Therapy: same as MC-2000
Hemoperfusion Therapy:same as MC-2000
Plasma exchange Therapy:same as MC-2000
Na+and UF profiling:
Be applicable for reducing the cases during dialysis treatment such as low/high pressure,muscle convulsion, headache,nausea,vomit ect.
Kt/V function:
The sufficiency of dialysis can be reflected by Kt/V.
HCO3 adjustment function:
Be applicable for sericous acid toxicosis patient.
Be capable to calibrate the acid toxicosis status according to patient's state of illness.
Backup power-supply:
It can last for 15-30 minutes after power cut off.
Pyrogen filter port:
Completely filtrating the remained bacteria and endotoxin.(optional)
Net connection:
One computer can audit and control the treatment of maximum 20 units hemodialysis machine (optional)