China Ce Approved Hospital Medical Hemodialysis Machine Kidney Dialysis Machine, Find details about China Hemodialysis Machine, Surgical Hemodialysis Device from Ce Approved Hospital Medical Hemodialysis Machine Kidney Dialysis Machine
CE Approved Hospital Medical Hemodialysis Machine Kidney Dialysis Machine
Description:
Dialysis machine for Toxuria/Uremia Patients blood purification. Hemodialysis Device JHM-2028M more comprehensive features
*Combine with Hemodialysis,Hemoperfusion,ISO UF, Hemoperfusion,Plasa Exchange all-in-one *Multi-language LCD touch screen with high defintion display interface. *Air bubble monitor :optical and ultrasonic double control,can monitor blood level and accumulate air bubble
*With safe and sensitive blood leakage monitor device
*Complete water-way and electric way apart design,individual waterway control system to ensure the security
*Dialysate temperature with high precision,safety control at 35-39 centigrade *Protection from intercross infection,fluid supply loop and return loop and return loop is completely divided during disinfection to avoid polution of whole machine in the case of mis-sucking disinfection liquid
*Conductivity control and protection:conductivity A,mix,conductivity,waer outlet conductivity,insure patient's security
*Adjustable Na+curve profile,with multiplicate optional auto-adjust program,can realize indiviual dialysis and ensure patient's safety
Extracorporeal circulation system | |
Blood pump flow | 20-620ml/min |
Blood pump segment Dia. | 6.4 and 8mm adjustable |
Heparin pump flow scope | 0-10ml/h |
Syringe | 10ml/20ml/30ml;20ml/30ml/50(optional) |
Arterial and pressure monitor | `-300~+400mmHg(+-10mmHg) |
Venous Pressure monitor | `-50~+300mmHg(+-10mmHg) |
Air bubble detector | Infrared and ultrasound detection |
Dialysis System | |
Dialysis flow | 300-800ml/min linearly adjustable(+10%,-5%) |
Dialysate temperratue scope | 35.0-39.0 centigrade |
Conductivity | 12.3-15.8mS/cm |
Na+ adjustment scope | 136-145mmol/L |
HCO3-adjustment scope | 28.0-42.0mmol/L |
Bicarb Cartridge | Optional |
Blood leakage dectction | |
Method | Photoelectricity detection |
Ultrafiltration controlling system | |
Ultrafiltration ratio | 0-4000ml/h |
Pump volume accuracy | `+-1% |
Disinfection and rinse | |
Rinse and heat disinfection (above 90centigrade) | |
Chemical disinfection | Peracetic aclid |
Heat chemical disinfection | Citric acid |
Other parameter | |
Dimension | L*W*H 370mm*340mm*1450mm |
Weight | 90KG |
Power supply voltage | 100-240V Ac+-10% 50`60Hz |
Power supply voltage | 1.7KW |
Back-up battery | At least 30minutes working after cut |
Working environment | Temperature:10-30centigrade |
Relative humidity no higher than 70% | |
Water supply temperature | Great compatibility be applicable for various concentration |
Dialysate formula | ratio formula |
Pressure | 0.12-0.6Mpa |