China Water Monitor System TDS pH Temp Multiparameter Water Quality Probe Sensor Electrode, Find details about China Sensor Water, Water Quality Detector from Water Monitor System TDS pH Temp Multiparameter Water Quality Probe Sensor Electrode
Features :
Menu:menu structure, similar to computer operation, simple, prompt, easy use.
Current isolated output: six independent 4 ~ 20mA current, coupled with optical isolation technology, strong
anti-jamming capability, remote transmission.
RS485 communication interface: can be easily linked to computer for monitoring and communication.
Automatic temperature compensation: 0 ~ 99.9 °C Automatic Temperature Compensation.
Waterproof and dustproof design: protection class IP65, suitable for outdoor use.
Depth (Pressure) | Principle | Pressure-sensitive Method |
Range | 0-61m(Maximum withstand pressure depth: 30M) | |
Resolution | 2cm | |
Accuracy | ±0.3% | |
Temperature | Principle | Thermistor method |
Range | 0ºC~50ºC | |
Resolution | 0.01ºC | |
Accuracy | ±0.5ºC | |
pH sensor | Principle | Glass electrode method |
Range | 0-14 pH | |
Resolution | 0.01 pH | |
Accuracy | ±0.1 pH | |
ORP Sensor | Principle | Glass electrode method |
Range | -1000mV ~+1000mV | |
Resolution | 0.01mV | |
Accuracy | ±5mV | |
Conductivity sensor | Principle | A pair of platinum gauze electrode |
Range | 1us/cm-2000 us/cm(K=1) 100us/cm-100ms/cm(K=10.0) | |
Resolution | 0.1us/cm~0.01ms/cm(Depending on the range) | |
Accuracy | ±3% | |
Turbidity sensor | Principle | Light scattering method |
Range | 0-1000NTU | |
Resolution | 0.1NTU | |
Accuracy | ± 5% or 0.3NTU, whichever is greater | |
DO Probe | Principle | Fluorescence |
Range | 0 -20 mg/L;0-20 ppm;0-200% | |
Resolution | 0.1%/0.01mg/l | |
Accuracy | ±3% or ±0.3 mg/L, whichever is greater |
Chlorophyll sensor | Principle | Fluorescence |
Range | 0-500 ug/L | |
Resolution | 0.01 ug/L~0.1 ug/L, Depending on range | |
Accuracy | ±5% of the signal level corresponding value of 1ppb Rhodamine WT Dye | |
Blue-green algae sensor | Principle | Fluorescence |
Range | 200-300,000cells/mL | |
Resolution | 25cells/mL | |
Accuracy | ±10% of the signal level corresponding value of 1ppb Rhodamine WT Dye | |
Ammonia nitrogen Sensor | Principle | Ion selection |
Range | 0.1~100mg/L-N | |
Resolution | 0.01mg/L-N | |
Accuracy | ±10% or ±2mg/L | |
Nitrate nitrogen Sensor | Principle | Ion selection |
Range | 0.5~100mg/L-N | |
Resolution | 0.01mg/L-N | |
Accuracy | ±10% or ±2mg/L | |
Chloride Sensor | Principle | Ion selection |
Range | 3~1000mg/L | |
Resolution | 0.01~1mg/L | |
Accuracy | ±10% or ±2mg/L | |
Fluoride Sensor | Principle | Ion selection |
Range | 0.5~1000mg/L | |
Resolution | 0.01~1mg/L | |
Accuracy | ±10% or ±2mg/L |