China 30kVA 45kVA 60kVA 90kVA 120kVA 180kVA 200kVA 300kVA 400kav 600kVA 800kav 1000kVA 50Hz 60Hz 400Hz Static Frequency Converter AC DC Power Source, Find details about China AC Power Source, 400Hz AC Power Source from 30kVA 45kVA 60kVA 90kVA 120kVA 180kVA 200kVA 300kVA 400kav 600kVA 800kav 1000kVA 50Hz 60Hz 400Hz Static Frequency Converter AC DC Power Source
Model | ACME 400-13005 | ACME 400-13010 | ACME 400-13030 | ACME 400-13050 | ACME 400-13100 | |||
Capacity | 500VA | 1KVA | 3KVA | 5KVA | 10KVA | |||
Circuit model | IGBT/SPWM | |||||||
Input | phase | single phase | ||||||
voltage | 220V±10% | |||||||
frequency | 50Hz/60Hz/±10% | |||||||
Output | Phase | three phase four wire | ||||||
Waveform | SINE WAVE | |||||||
Voltage | phase voltage | Rated:115V,0-150V Continuing Adjust | ||||||
Wire voltage | Rated:200V,0-260V Continuing Adjust | |||||||
Load stability | ≤1% | |||||||
Frequency | 400HZ, 300HZ-500HZ Continuing Adjust(can be customized) | |||||||
Frequency stability | Rated frequency≤0.1%;Adjustment range≤0.01% | |||||||
Wave distortion | THD≤3% | |||||||
Phase difference | phase position120°≤±2°,Phase voltage difference<3%rated value | |||||||
Efficiency | ≥80%(100%Load) | |||||||
Reaction time | ≤2mS | |||||||
Display | High precision LED display, Voltage, current, frequency, power and power factor | |||||||
Cooling | Compulsive fan cooling | |||||||
Noise | ≤55dB(1m) | |||||||
Protection function | over voltage, over current, over temperature, over load, short circuit, and automatic alarm | |||||||
Reliability | MTBF | h1.0*105 h | ||||||
MTTR | 0.5 h | |||||||
Environment | Working temperature/ Relative humidity | -25ºC-55ºC/0-90%(No condensing) | ||||||
Altitude | ≤2000meters |
Model | ACME 400-33150 | ACME 400-33200 | ACME 400-33300 | ACME 400-33450 | ACME 400-33600 | ||
Capacity | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | ||
Circuit model | IGBT/SPWMpulse width adjustment mode | ||||||
Input | Phase | three phase | |||||
Voltage | 380V±10% | ||||||
Frequency | 50Hz/60Hz/±10% | ||||||
Output | Phase | three phase four wire | |||||
Waveform | SINE WAVE | ||||||
Voltage | phase voltage | Rated:115V,0-150V Continuing Adjust | |||||
Wire voltage | Rated:200V,0-260V Continuing Adjust | ||||||
Load stability | ≤1% | ||||||
Frequency | 400HZ, 300HZ-500HZ Continuing Adjust(can be customed) | ||||||
Frequency stability | Rated frequency≤0.1%;Adjustment range≤0.01% | ||||||
Wave distortion | THD≤3% | ||||||
Phase difference | phase position120°≤±2°,Phase voltage difference<3%rated value | ||||||
Efficiency | ≥80%(100%Load) | ||||||
Reaction time | ≤2mS | ||||||
Ammeter display | Precision four-digit LED display lights,Voltage current frequency power and power factor | ||||||
Cooling | Compulsive fan cooling | ||||||
Noise | ≤55dB | ||||||
Protection function | over voltage, over current, over temperature, over load, short circuit, and automatic alarm | ||||||
Reliability | MTBF | 1.0*105 h | |||||
MTTR | 0.5 h | ||||||
Environment | Working temperature/ Relative humidity | -25ºC-55ºC/0-90%(No condensing) | |||||
Altitude | ≤2000meters |
Model | ACME 400-33750 | ACME 400-331000 | ACME 400-331500 | ACME 400-332000 | ACME 400-333000 | ||
Capacity | 75KVA | 100KVA | 150KVA | 200KVA | 300KVA | ||
Circuit model | IGBT/SPWMpulse width adjustment mode | ||||||
Input | Phase | three phase | |||||
Voltage | 380V±10% | ||||||
Frequency | 50Hz/60Hz/±10% | ||||||
Output | Phase | three phase four wire | |||||
Waveform | SINE WAVE | ||||||
Voltage | phase voltage | Rated:115V,0-150V Continuing Adjust | |||||
Wire voltage | Rated:200V,0-260V Continuing Adjust | ||||||
Load stability | ≤1% | ||||||
Frequency | 400HZ, 300HZ-500HZ Continuing Adjust(can be customed) | ||||||
Frequency stability | Rated frequency≤0.1%;Adjustment range≤0.01% | ||||||
Wave distortion | THD≤3% | ||||||
Phase difference | phase position120°≤±2°,Phase voltage difference<3%rated value | ||||||
Efficiency | ≥80%(100%Load) | ||||||
Reaction time | ≤2mS | ||||||
Ammeter display | Precision four-digit LED display lights,Voltage current frequency power and power factor | ||||||
Cooling | Compulsive fan cooling | ||||||
Noise | ≤55dB | ||||||
Protection function | over voltage, over current, over temperature, over load, short circuit, and automatic alarm | ||||||
Reliability | MTBF | h1.0*105 h | |||||
MTTR | 0.5 h | ||||||
Environment | Working temperature/ Relative humidity | -25ºC-55ºC/0-90%(No condensing) | |||||
Altitude | ≤2000meters |